The auto drain port comes with 3/8" One-touch fitting (applicable to the AC30A-B to AC60A-B). 2 Drain guide is G1/8 (applicable to the AC20A-B) and G1/4 (applicable to the AC30A-B to AC60A-B). 3 Options G, M are not assembled and supplied loose at the time of shipment. 4 When pressure is not applied, condensate which does not start the auto drain mechanism will be left in the bowl.
AC20A-D to AC60A-D Series Optional specifications AC AF + AR + AL AW + AL AF + AR AF + AFM + AR AW + AFM Attachments AF AFM / AFD AR AL AW Applicable model Square embedded type pressure gauge Digital pressure switch Round type pressure gauge Round type pressure gauge (with color zone) J J J AC20A-D to AC60A-D H H H Center of piping Center of piping Center of piping Optional specifications
AC20A-D to AC60A-D AC20A-D AC30A-D AC40A-D to AC60A-D Optional specifications Applicable Square embedded type pressure gauge Digital pressure gauge Round type pressure gauge Round type pressure gauge model (with color zone) AC20A-D to AC60A-D Optional specifications Semi-standard specifications Applicable PC/PA bowl Metal bowl Metal bowl with level gauge model With auto drain Drain cock with
Note 1) Drain guide is NPT1/8 (applicable to the AC20A-B) and NPT1/4 (applicable to the AC30A-B to AC60A-B). The auto drain port comes with 3/8" One-touch fitting (applicable to the AC30A-B to AC60A-B). Note 2) Drain guide is G1/8 (applicable to the AC20A-B) and G1/4 (applicable to the AC30A-B to AC60A-B). Note 3) Option G, M are not assembled and supplied loose at the time of shipment.
For AC10 For AC10A For AC10B G27-10-R1 G27-10-R1 Note 3) For AC40-06 For AC40A-06 For AC40B-06 For AC40C-06 For AC40D-06 For AC50 For AC50A For AC50B For AC25 For AC25B For AC25C For AC55 For AC55B For AC30 For AC30A For AC30B For AC30C For AC30D For AC60 For AC60A For AC60B For AC40 For AC40A For AC40B For AC40C For AC40D For AC20 For AC20A For AC20B For AC20C For AC20D Section
177 164 160 AWM30/AWD30 41 40 46 6.5 8 53 2.3 31 38.5 19 7 242 209 208 214 234 AWM40/AWD40 50 54 54 8.5 10.5 70 2.3 35.5 42.5 21 7 278 247 246 252 272 Note) The total length of B dimension is the length when the filter regulator handle is unlocked. 72 Options Digital Pressure Switch ISE35 N 25 M L A Applicable Series AC20, AC25, AC30, AC40, AC50, AC55, AC60 AC20A, AC30A, AC40A, AC50A, AC60A
177 164 160 AWM30/AWD30 41 40 46 6.5 8 53 2.3 31 38.5 19 7 242 209 208 214 234 AWM40/AWD40 50 54 54 8.5 10.5 70 2.3 35.5 42.5 21 7 278 247 246 252 272 Note) The total length of B dimension is the length when the filter regulator handle is unlocked. 72 Options Digital Pressure Switch ISE35 N 25 M L A Applicable Series AC20, AC25, AC30, AC40, AC50, AC55, AC60 AC20A, AC30A, AC40A, AC50A, AC60A
ISE35 N 25 M L A Applicable Series AC20, AC25, AC30, AC40, AC50, AC55, AC60 AC20A, AC30A, AC40A, AC50A, AC60A Symbol Description F.R.L. unit AC20B, AC25B, AC30B, AC40B, AC50B, AC55B, AC60B AC20C, AC25C, AC30C, AC40C AC20D, AC30D, AC40D AR20(K), AR25(K), AR30(K), AR40(K), AR50(K), AR60(K) AW20(K), AW30(K), AW40(K), AW60(K) AWM20, AWM30, AWM40 N Wiring bottom entry Regulator Filter regulator
Model: E600 (Applicable Models: AC50-B, AC55-B, AC60-B, AC50A-B, AC60A-B, AC50B-B, AC55B-B, AC60B-B), Thread: F (G), Port Size: 06 (3/4)
Model: E600 (Applicable Models: AC50-B, AC55-B, AC60-B, AC50A-B, AC60A-B, AC50B-B, AC55B-B, AC60B-B), Thread: F (G), Port Size: 10 (1)
Model: E600 (Applicable Models: AC50-B, AC55-B, AC60-B, AC50A-B, AC60A-B, AC50B-B, AC55B-B, AC60B-B), Thread: N (NPT), Port Size: 06 (3/4)
Model: E600 (Applicable Models: AC50-B, AC55-B, AC60-B, AC50A-B, AC60A-B, AC50B-B, AC55B-B, AC60B-B), Thread: N (NPT), Port Size: 10 (1)
Model: E600 (Applicable Models: AC50-B, AC55-B, AC60-B, AC50A-B, AC60A-B, AC50B-B, AC55B-B, AC60B-B), Thread: Rc, Port Size: 10 (1)
Model: E600 (Applicable Models: AC50-B, AC55-B, AC60-B, AC50A-B, AC60A-B, AC50B-B, AC55B-B, AC60B-B), Thread: Rc, Port Size: 06 (3/4)
For AC10 For AC10A For AC10B G27-10-R1 G27-10-R1 Note 3) For AC40-06 For AC40A-06 For AC40B-06 For AC40C-06 For AC40D-06 For AC50 For AC50A For AC50B For AC25 For AC25B For AC25C For AC55 For AC55B For AC30 For AC30A For AC30B For AC30C For AC30D For AC60 For AC60A For AC60B For AC40 For AC40A For AC40B For AC40C For AC40D For AC20 For AC20A For AC20B For AC20C For AC20D Section
Model Product series AC20/AC25/AC30/AC50/AC55/AC60 AC20A/AC30A/AC40A/AC50A/AC60A AC20B/AC25B/AC30B/AC50B/AC55B/ AC60B AC20C/AC25C/AC30C/AC40C AC20D/AC30D/AC40D AR20 (K) /AR25 (K) /AR30 (K) /AR40 (K) / AR50 (K) /AR55 (K) /AR60 (K) AW20 (K) /AW30 (K) /AW40 (K) /AW60 (K) F.R.L. combination Option/Part No.
F.R.L. unit with digital pressure switch (-X465 option); Pressure switch model: ISE30---L; Pressure switch set pressure range: -0.1 to 1 MPa; Pressure gauge port size: Rc1/8; Applicable on models: AC20A, AC25A, AC30A, AC40A,AC40A-06, AC50A, AC55A, AC60A
Resin] Polycarbonate Case, Case Guard: No, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [Not Provided] No, Pressure Gauge: -, Residual Pressure Relief 3-Port Connection Valve: None, Set Pressure: -, Pressure Unit: Name plate and pressure gauge unit: MPa, T shape spacer: None, Compatible Model: AC50-B, AC55-B, AC60-B, AC50A-B, AC60A-B
Resin] Polycarbonate Case, Case Guard: No, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [Not Provided] No, Pressure Gauge: -, Residual Pressure Relief 3-Port Connection Valve: None, Set Pressure: -, Pressure Unit: Name plate and pressure gauge unit: MPa, T shape spacer: None, Compatible Model: AC50-B, AC55-B, AC60-B, AC50A-B, AC60A-B
Resin] Polycarbonate Case, Case Guard: No, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [Not Provided] No, Pressure Gauge: -, Residual Pressure Relief 3-Port Connection Valve: None, Set Pressure: -, Pressure Unit: Name plate and pressure gauge unit: MPa, T shape spacer: None, Compatible Model: AC50-B, AC55-B, AC60-B, AC50A-B, AC60A-B