This is a legacy product, and replaced byAF60-F10D-A, FILTER, MODULAR, AIRLINE EQUIPMENT, AF MASS PRO, HA, AF MASS PRO 1" MODULAR (PT), 2.77784 lb
This is a legacy product, and replaced byAF50-F10D-R-A, FILTER, MODULAR, AIRLINE EQUIPMENT, AF MASS PRO, HA, AF MASS PRO 1 MODULAR (PT), 1.32277 lb, ModelPort sizeFluidAmbient and fluid temperatureProof pressureMaximum operating pressureNominal filtration ratingDrain capacity (cm3)Bowl materialBowl guardMass (kg)AF503/4, 1Air?
This is a legacy product, and replaced byAW60-F10D-B, FILTER REGULATOR, MODULAR, AIRLINE EQUIPMENT, AW MASS PRO, HA, AW MASS PRO 1" MODULAR (PT), 4.64544 lb
(The SI unit type is provided for use in Japan.) *3 v: For the pipe thread type: NPT only *4 The VHS50 can be connected to the AC60.
Note 14) Without a valve function Note 1) Drain guide is NPT1/8 (applicable to the AC20-B) and NPT1/4 (applicable to the AC25-B to AC60-B). The auto drain port comes with 3/8" One-touch fitting (applicable to the AC25-B to AC60-B). Note 2) Drain guide is G1/8 (applicable to the AC20-B) and G1/4 (applicable to the AC25-B to AC60-B).
The auto drain port comes with 3/8" One-touch fitting (applicable to the AC25-B to AC60-B). 2 Drain guide is G1/8 (applicable to the AC20-B) and G1/4 (applicable to the AC25-B to AC60-B). 3 Options G, M are not assembled and supplied loose at the time of shipment. 4 When pressure is not applied, condensate which does not start the auto drain mechanism will be left in the bowl.
(This is not applicable to VHS40 and VHS50) Body size Applicable model AC20 AC25/30 AC40 AC50, AC60 Note) Symbol 20 30 40 50 Effective area (mm2) 5 5 Model VHS20 VHS30 Note) When the valve is mounted on AC60, the flow rate may decrease depending upon the mounting position.
(This is not applicable to VHS40 and VHS50) Body size Applicable model AC20 AC25/30 AC40 AC50, AC60 Note) Symbol 20 30 40 50 Effective area (mm2) 5 5 Model VHS20 VHS30 Note) When the valve is mounted on AC60, the flow rate may decrease depending upon the mounting position.
(This is not applicable to VHS40 and VHS50) Body size Symbol 20 30 40 50 Applicable model AC20 AC25,30 AC40 AC50, AC60Note) Note) When the valve is mounted on AC60, the flow rate may decrease depending upon the mounting position.
(This is not applicable to VHS40 and VHS50) Body size Symbol 20 30 40 50 Applicable model AC20 AC25,30 AC40 AC50, AC60Note) Note) When the valve is mounted on AC60, the flow rate may decrease depending upon the mounting position.
Optional specifications Note 2) With barb fitting B With drain guide B Metal bowl B 85 123 166 166 200 200 276 292 293 Metal bowl with level gauge Model B V AC10 AC20 AC25 AC30 AC40 AC40-06 AC50 AC55 AC60 161 161 195 195 272 287 288 160 160 194 194 271 286 287 186 186 220 220 296 312 313 38 38 45 45 45 45 45 4 F.R.L.
AC20-D to AC60-D AC20-D AC30-D AC40-D to AC60-D Optional specifications Applicable Square embedded type Round type pressure gauge model Digital pressure gauge Round type pressure gauge pressure gauge (with color zone) AC20-D to AC60-D Optional specifications Semi-standard specifications Applicable PC/PA bowl Metal bowl Metal bowl with level gauge model With auto drain Drain cock with barb
Note 1) Drain guide is NPT1/8 (applicable to the AC20-B) and NPT1/4 (applicable to the AC25-B to AC60-B). The auto drain port comes with 3/8" One-touch fitting (applicable to the AC25-B to AC60-B). Note 2) Drain guide is G1/8 (applicable to the AC20-B) and G1/4 (applicable to the AC25-B to AC60-B). Note 3) Option G, M are not assembled and supplied loose at the time of shipment.
For International inquiries: www.smcworld.com Pressure relief Spacer with bracket P/N Applicable air Interface P/N 3-port valve preparation equipment Y200 Y300 Y400 Y500 Y600 Y200T Y300T Y400T Y500T Y600T VHS20 VHS30 VHS40 AC20 AC25, AC30 AC40 AC40-06 VHS40-06 Note) AC50, AC60 VHS50 Note) Although connection to AC60 is possible, the flow rate may decrease due to the mounting position. 2015
Applicable air preparation equipment VHS20 VHS30 VHS40 VHS40-06 VHS50 Y200-A Y300-A Y400-A Y500-A Y600-A AC20-A AC25-A, AC30-A AC40-A AC40-06-A AC50, AC55 Note), AC60 Note) Y200T-A Y300T-A Y400T-A Y500T-A Y600T-A Note) VHS50 can be connected to AC55 and AC60.
Recommended Torque Unit: Nm model AC20 AC30 AC40 AC50 AC60 Applicable Spacer with Bracket part no. Y200-T-D Y300-T-D Y400-T-D Y600-T-D Spacer part no. Y200-D Y300-D Y400-D Y600-D Torque 0.36 1.2 1.2 2.0 0.036 0.05 0.05 0.1 6.
SUP SUP IN OUT Applicable air preparation equipment Spacer with bracket P/N Pressure relief 3 port valve VHS20 VHS30 VHS40 VHS40-06 VHS50 Interface P/N AC20 AC25, AC30 AC40 AC40-06 AC50, AC60 Note) Y200 Y300 Y400 Y500 Y600 Y200T Y300T Y400T Y500T Y600T Spacer with bracket Note) Although connection to AC60 is possible, the flow rate may decrease due to the mounting position. 5-8-20 3 Series
SUP SUP IN OUT Applicable air preparation equipment Spacer with bracket P/N Pressure relief 3 port valve VHS20 VHS30 VHS40 VHS40-06 VHS50 Interface P/N AC20 AC25, AC30 AC40 AC40-06 AC50, AC60 Note) Y200 Y300 Y400 Y500 Y600 Y200T Y300T Y400T Y500T Y600T Spacer with bracket Note) Although connection to AC60 is possible, the flow rate may decrease due to the mounting position. 5-8-20 3 Series
Y200-A Y300-A Y400-A Y500-A Y600-A Applicable air preparation equipment AC20-A AC25-A, AC30-A AC40-A AC40-06-A AC50, AC55 Note), AC60 Note) Y200T-A Y300T-A Y400T-A Y500T-A Y600T-A VHS20 VHS30 VHS40 VHS40-06 VHS50 Note) VHS50 can be connected to AC55 and AC60. Spacer IN OUT Spacer with bracket 1