Series: 1 (VQZ1000), Configuration: 1 (2 Position Single), Seal Type: 1 (Rubber Seal), Function: Standard (0.35W DC, AC), Coil Voltage: 5 (24VDC), Lead Wire: L (L Plug Connector w/Lead Wire, Light & Surge Suppressor), Manual Override: Non-locking Push Style, IP65 Compliant: No, Port Size: C6 (ø6 One-touch Fitting), Thread: Rc, Foot Bracket: None, CE Compliant: Q (CE Marked)
Blanking plate VVQ1000-10A-1 Individual SUP spacer VVQ1000-P-1-C6 SUP shutoff position: Specify 2 positions. Individual EXH spacer VVQ1000-R-1-C6 EXH shutoff position: Specify 2 positions.
P reduced pressure A reduced pressure B reduced pressure ARB350-00-P ARB350-00-A ARB350-00-B A B A B 27 Series VQ7-8 Manifold Options Interface regulator Main EXH back pressure check plate P A B ARB350-00AXT512-25A Interface regulator Main EXH back pressure check plate (AXT512-25A) 282 ARB350-00P A B 146 SMC SMC 238.5 (208) 221 226.5 (196) 209 193.5 181.5 135.5 (105) 118 PA B PE PE P 90.5
P reduced pressure ARB350-00-P A B A B A reduced pressure ARB350-00-A B reduced pressure ARB350-00-B 3-10-32 33 ISO Standard Solenoid Valve: Size 2 Metal Seal/Rubber Seal Series VQ7-8 Manifold Option Parts Main EXH back pressure check plate AXT512-25A Interface regulator ARB350-00P A B Interface regulator Main EXH back pressure check plate (AXT512-25A) 282 ARB350-00P A B 146 VK VZ SMC SMC
6.5 mm, and 9 mm for C6.
(The standard valve has an individual exhaust for the pilot valve.) 4-14-40 41 Series VQZ Replacement Parts Base Mounted One-touch Fitting Assembly (For cylinder port) C3 C4 C6 C8 C10 Fitting size M5 (VQZ100 only) Model VQZ100 VVQ1000-50A-C3 VVQ1000-50A-C4 VVQ1000-50A-C6 VVQ1000-50A-M5 V100 VQZ200 VVQ1000-51A-C4 VVQ1000-51A-C6 VVQ1000-51A-C8 VQZ300 VVQ2000-51A-C6 VVQ2000-51A-C8 VVQ2000-51A-C10
VQC4000 VVQC4000-2A-1 Thread type Nil F T Rc G NPT/NPTF 22 Manifold Specification Sheet Series VQC1000: Base-Mounted Type/Plug-in Unit q How to order manifolds VV5QC 1 1 08 FD1 B C6 F P T Kit / / 1 2 3 8 VV5QC 1 1 08 SDQ B C6 S Kit Fill out for I/O serial kit only.
Series: 1 (VQZ1000), Configuration: 1 (2 Position Single), Seal Type: 1 (Rubber Seal), Function: Standard (0.35W DC, AC), Coil Voltage: 5 (24VDC), Lead Wire: L (L Plug Connector w/Lead Wire, Light & Surge Suppressor), Manual Override: Non-locking Push Style, IP65 Compliant: No, Port Size: C6 (ø6 One-touch Fitting), Thread: Rc, Foot Bracket: F (Bracket), CE Compliant: Q (CE Marked)
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard / Lubrication Free, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Open, Applicable Cylinder Diameter(Ø): 63 or less, Pipe Port Type: One-Touch Plumbing, Port Size: -, Connecting Tube Diameter: Ø6, Driving
Note 2) ( ): Denotes without sub-plate. 5-2-6 5 5 Port Air Operated Valve Series SYA3000/5000/7000 Series SYA3000: Body Ported Foot bracket SYA3120-F1 C4, N3 C6, N7 2 position single SYA3120(-F2) C4, N3 C6, N7 One-touch fitting (A, B port) M5 x 8 (Pilot port) Applicable tubing O.D.: 4, 1/4" 6, 5/32" Manual override (Non-locking) SA VA 2 2.2 (For manifold mounting) SA 2 3.2 (For mounting
C Port plug 1 See below PBT, HNBR D Clip 3 136010 Stainless steel One-touch Fittings for Centralized Supply Block Port Plug VVQ0 58A VVQ1000 51A C6 Single unit regulator/ Port plug for regulator block One-touch fittings for centralized supply block Nil L1 Fitting type Straight Elbow Fitting size 10 Size 6 8 1/4 5/16 Symbol C6 C8 N7 N9 Note) The O-ring is attached.
Electrical Wiring Specifications Lead wire specifications Lead wire length Lead wire 0.3 mm2 25 core VV5QC11 08 C6 LD 0 As the standard electrical wiring specification used is for 12 stations or less, double wiring (connected to SOL. A and SOL. B) is used for the internal wiring of each station regardless of valve and option types.
Wl] Flcl /8 C4: Wlth 04 One-louch fitling, C6: With s6 One-tolrch lining, M5: 1,15 remale threads Nole 1) Eauipped with unit switchirg {u.rction (Types wirho{i the unit swirching lunction use Sl unils (kPa or MPa) only ) Noie 2) For zSE4o (F)/lSFaoS-g Note 3) For ZSE4o (F)/lSE4o-tr* Note 4) For ZSE4OF (compound pressure) with "psi" indication, this rs 0 03 to 0 04 psi Note 5) For ZSE4OF {
Wl] Flcl /8 C4: Wlth 04 One-louch fitling, C6: With s6 One-tolrch lining, M5: 1,15 remale threads Nole 1) Eauipped with unit switchirg {u.rction (Types wirho{i the unit swirching lunction use Sl unils (kPa or MPa) only ) Noie 2) For zSE4o (F)/lSFaoS-g Note 3) For ZSE4o (F)/lSE4o-tr* Note 4) For ZSE4OF (compound pressure) with "psi" indication, this rs 0 03 to 0 04 psi Note 5) For ZSE4OF {
Series: VQZ1000, Configuration: 2 Position Single, Seal Type: Rubber Seal, Function: Standard (0.35W DC, AC), Coil Voltage: 24VDC, Lead Wire: L Plug Connector w/Lead Wire, Light & Surge Suppressor, Manual Override: Non-locking Push Style, IP65 Compliant: No, Port Size: 1/4" One-touch Fitting, Thread: NPTF, Foot Bracket: -, CE Compliant: -
Series: VQZ1000, Configuration: 2 Position Single, Seal Type: Rubber Seal, Function: Standard (0.35W DC, AC), Coil Voltage: 24VDC, Lead Wire: L Plug Connector w/Lead Wire, Light & Surge Suppressor, Manual Override: Non-locking Push Style, IP65 Compliant: No, Port Size: M5 Thread, Thread: NPTF, Foot Bracket: -, CE Compliant: -
Series: VQZ1000, Configuration: 2 Position Single, Seal Type: Rubber Seal, Function: Standard (0.35W DC, AC), Coil Voltage: 24VDC, Lead Wire: L Plug Connector w/Lead Wire, Light & Surge Suppressor, Manual Override: Non-locking Push Style, IP65 Compliant: No, Port Size: 1/8" One-touch Fitting, Thread: -, Foot Bracket: -, CE Compliant: -
Series: VQZ1000, Configuration: 2 Position Single, Seal Type: Rubber Seal, Function: Standard (0.35W DC, AC), Coil Voltage: 24VDC, Lead Wire: L Plug Connector w/Lead Wire, Light & Surge Suppressor, Manual Override: Non-locking Push Style, IP65 Compliant: No, Port Size: 1/4" One-touch Fitting, Thread: -, Foot Bracket: -, CE Compliant: -
Series: VQZ1000, Configuration: 2 Position Single, Seal Type: Rubber Seal, Function: Standard (0.35W DC, AC), Coil Voltage: 24VDC, Lead Wire: L Plug Connector w/Lead Wire, Light & Surge Suppressor, Manual Override: Non-locking Push Style, IP65 Compliant: No, Port Size: 5/32" One-touch Fitting, Thread: -, Foot Bracket: -, CE Compliant: -
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard / Lubrication Free, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Open, Applicable Cylinder Diameter(Ø): -, Pipe Port Type: One-Touch Plumbing, Port Size: -, Connecting Tube Diameter: Ø3.2, Driving Type