SMC Corporation of America
Elite Part Number Search
Search Results "25A-MY3B32-1600"

Example) When LEFSH25RH-300 isordered, input LEFS25RH-300 (c) When a Clean type (11-) or Secondary battery type (25A-) is ordered. Search without inputting 11or 25A-, and find the actuator to which 11or 25Ais applicable.

Example) When LEFSH25RH-300 isordered, input LEFS25RH-300 (c) When a Clean type (11-) or Secondary battery type (25A-) is ordered. Search without inputting 11or 25A-, and find the actuator to which 11or 25Ais applicable.

Bore sizes: 16, 20, 25, 32, 40, 50, 63 mm; Stroke lengths: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000 mm; Minimum operating pressure: 0.15~0.20 MPa (22~29 psi); Speed: 80~500 mm/sec (MY3A), 80~1000 mm/sec (MY3B), 80~1500 mm/sec (external shock absorber); Auto switch capable; Series 25A-MY3* is compatible with secondary battery applications

Bore sizes: 16, 20, 25, 32, 40, 50, 63 mm; Stroke lengths: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000 mm; Minimum operating pressure: 0.15~0.20 MPa (22~29 psi); Speed: 80~500 mm/sec (MY3A), 80~1000 mm/sec (MY3B), 80~1500 mm/sec (external shock absorber); Auto switch capable; Series 25A-MY3* is compatible with secondary battery applications

1 Controller mounting * Select the LECP2 when setting the stroke range using the stroke adjustment unit or an external stopper. 11LEJS Nil Without cable (Without communication plug connector)*2 Nil Screw mounting D DIN rail mounting* 1 1.5 m 3 3 m 5 5 m S Straight type communication plug connector*2 25A* DIN rail is not included. Order it separately.

Bore sizes: 16, 25, 40, 63 mm; Stroke lengths: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000 mm; Minimum operating pressure: 0.15 ~ 0.20 MPa (22 ~ 29 psi); Speed: 80~1000 mm/sec (w/o stroke adjustment bolt), 80~1500 mm/sec (external shock absorber); Auto switch capable; Series 25A-MY3M is compatible with secondary battery applications

Bore sizes: 16, 25, 40, 63 mm; Stroke lengths: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000 mm; Minimum operating pressure: 0.15 ~ 0.20 MPa (22 ~ 29 psi); Speed: 80~1000 mm/sec (w/o stroke adjustment bolt), 80~1500 mm/sec (external shock absorber); Auto switch capable; Series 25A-MY3M is compatible with secondary battery applications

Style: B (Standard Type-Air Cushion), Bore Size: 32mm, Port Thread: Rc: ø25, ø40, ø50, ø63/M Thread: ø16, Stroke: 1600mm

Style: Standard Type-Air Cushion, Bore Size: 32mm, Port Thread: Rc: ø25, ø40, ø50, ø63/M Thread: ø16, Stroke: 1600mm, Stroke Adjusting Unit: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Style: B (Standard Type-Air Cushion), Bore Size: 32mm, Port Thread: Rc: ø25, ø40, ø50, ø63/M Thread: ø16, ø20, Stroke: 600mm

Style: Standard Type-Air Cushion, Bore Size: 32mm, Port Thread: Rc: ø25, ø40, ø50, ø63/M Thread: ø16, ø20, Stroke: 600mm, Stroke Adjusting Unit: -, Auto Switch: -

Bore Size: 50mm, Piping: Standard Type, Stroke: 1600mm, Stroke Adjustment Unit: -, Option: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

1600 1890 1606 1730 18 8 1600 1700 1990 1706 1830 20 9 1800 1800 2090 1806 1930 20 9 1800 1900 2190 1906 2030 22 10 2000 2000 2290 2006 2130 22 10 2000 2500 2790 2506 2630 28 13 2600 Encoder cable (7) Motor cable (7) Note 1) When mounting the actuator using the body mounting reference plane, set the height of the opposite surface or pin to be 3 mm or more because of R chamfering.

Model LEFB25 LEFB32 LEFB40 300, 400, 500 600, 700, 800 900, 1000, (1100) 1200, (1300, 1400) 1500, (1600, 1700) (1800, 1900), 2000 2500 300, 400, 500 600, 700, 800 900, 1000, (1100) 1200, (1300, 1400) 1500, (1600, 1700) (1800, 1900), 2000 2500, 3000 300, 400, 500 600, 700, 800 900, 1000, (1100) 1200, (1300, 1400) 1500, (1600, 1700) (1800, 1900), 2000 LEF Stroke [mm] Note 1) LEJ Actuator specifications

300 mm 300 mm 300 mm 4 s 4 s 6 s 6 s 8 s 0 8 s 0 8 s 2 s 4 s 6 s 8 s 0 2 s 4 s 6 s 8 s 0 2 s 2 s 300 mm 300 mm 300 mm 300 mm 0 400 800 1200 1600 2000 Installation distance [mm] 0 400 800 1200 1600 2000 Installation distance [mm] 0 2000 0 400 800 1200 1600 2000 Installation distance [mm] 0 400 800 1200 1600 2000 Installation distance [mm] 1600 2000 m] Extensive static neutralization area can

), (1700), (1800), (1900), 2000 25 AC servo motor 54 300, 400, 500, 600, 700, 800, 900, 1000, (1100), 1200, (1300), (1400), 1500, (1600), (1700), (1800), (1900), 2000, 2500 32 54 300, 400, 500, 600, 700, 800, 900, 1000, (1100), 1200, (1300), (1400), 1500, (1600), (1700), (1800), (1900), 2000, 2500, 3000 40 1 The size corresponds to the bore of the air cylinder with an equivalent force.

Dimensions Ionizer/ IZS40 340 5 340 400 6 400 460 7 460 580 9 580 640 10 640 820 13 820 1120 18 1120 1300 21 1300 1600 26 1600 1900 31 1900 2320 38 2320 2500 41 2500 bar length Model Symbol for n (No. of cartridge), L IZS40 fitting A (mm) 06 13 08 15 10 22 Symbol for A Ionizer/ IZS41, IZS42 340 5 340 400 6 400 460 7 460 580 9 580 640 10 640 820 13 820 1120 18 1120 1300 21 1300 1600 26 1600

Nil P NPN PNP Bar length (mm) 340 400 460 580 640 820 1120 1300 1600 1900 2320 2500 With 2 pcs. 340 400 460 580 640 820 1120 1300 1600 1900 2320 2500 Since input/output function cannot be used, specify Nil when the AC adapter is being used.