VN Solenoid valve option Nil Standard Rated voltage 1 2 3 4 5 6 7 8 9 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz Other (Please contact SMC separately.) LVC Select an option mark in page 17-3-9 by Applicable Fluids Check List for special fluids outside of the standard.
VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Electrical entry: D or DZ only Electrical entry: D or DZ only Coil rated voltage 1 2 3 Note 1) 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 4 Note 1) Manual override 5 6 Note 1) Non-locking push type Nil A Electrical entry CE-compliant G Non-locking push type
size (mm) Symbol Port size Rc 1 2 3 Note) 4 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz Symbol N.C. 1 MPa N.C. 0.5 MPa N.O.
Seal Coil voltage 1 100 VAC (50/60 Hz) 2 200 VAC (50/60 Hz) 3 110 VAC (50/60 Hz) 4 220 VAC (50/60 Hz) 5 24 VDC 6 12 VDC Series Enter in order starting from the first station on the D side.
Flow-rate Characteristics (Pressure Loss) PF3W711/511 PF3W721/521 0.04 0.04 Pressure loss [MPa] Pressure loss [MPa] 0.03 0.03 0.02 0.02 0.01 0.01 0 0 0 20 40 60 80 100 0 50 100 150 200 250 Flow rate [L/min] Flow rate [L/min] Straight Piping Length and Accuracy (Reference Value) Pressure: 0.3 MPa PF3W711/721/511/521 Piping diameter: 25A, 30A Straight piping length p10 p8 Accuracy [% F.S.]
Piping Port size Orifice diameter [mm] Thread type Pilot port size With/without silencer (Option) 3/4 (20A) 32 Without Compression fitting type 1 (25A) 40 Without Rc NPT G Direct piping type (Rc, NPT, G) 1/8 1/4 1 1/2 (40A) 50 With Immersion type 1 (25A) 40 Without CAT.ES70-57B JSXFA Series Pulse Valve Valve for Dust Collector JSXFA Series Long service life: 10 million cycles1 or more A spring
/60 Hz 200 VAC 50/60 Hz 100 VAC 50/60 Hz Symbol A: Non-locking push type A (projecting) N.C. 0.5 MPa N.O. 1 MPa N.C. 1 MPa 4 1 6A 8A 10A 10A 15A 20A 25A 32A 1 8 1 4 3 8 3 8 1 2 3 4 220 VAC 50/60 Hz 7 Valve size 1 5 6 24 VDC 12 VDC B: Slotted locking type B (tool required) 7 240 VAC 50/60 Hz 15 (11) 2 Semi-standard For other rated voltages, please consult with SMC. 20 (14) 3 25 (16) 4 1
/60 Hz 200 VAC 50/60 Hz 100 VAC 50/60 Hz Orifice dia.
B: Locking slotted type 4 1 6A 8A 10A 10A 15A 20A 25A 32A 40A 50A 1 8 1 4 3 8 3 8 1 2 3 4 220 VAC 50/60 Hz 10 5 6 24 VDC 12 VDC 240 VAC 50/60 Hz 7 15 2 9 Other Nil: Non-locking push type 20 3 Option Valve size 5 to 7 25 4 1 1 1 2 32 5 1 4 1 2 40 50 6 7 Note) Air operated only Electrical entry/ With light/surge voltage suppressor E GS G Grommet with surge voltage suppressor Grommet Grommet
Rc G NPT NPTF Nil F N T None With bracket Nil B Valve type 1 3 N.C./3.5 MPa N.C./7.0 MPa Electrical entry/With light/surge voltage suppressor D DIN terminal Seal material DZ DIN terminal with light/surge voltage suppressor A B NBR seals FKM seals Rated voltage Valve size Port size 3 2 1 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 10A 15A 20A 25A 1 2 3 4 3 8 1 2 3 4
Gasket material A B NBR seals FKM seals Rated voltage Nil Air operated 3 2 1 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz Valve size Port size Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 3 8 1 2 3 4 Rc Rc Rc Rc1 10A 15A 20A 25A 1 2 3 4 4
C 5 to 45 Circulating fluid2 Tap water, 15% ethylene glycol aqueous solution, Deionized water Set temperature range1 C 5 to 35 Cooling capacity 50/60 Hz3 kW 8.0/9.0 Heating capacity 50/60 Hz4 kW 1.7/2.2 Temperature stability5 C 0.5 Circulating fluid system Rated flow 50/60 Hz (Outlet)6 L/min 29/45 Maximum flow rate 50/60 Hz L/min 55/68 Maximum pump head m 50 Minimum operating flow rate 50
Item Unit Standard value Influence 10 s Corrosion Scale generation 5 s pH (at 25C) 6.0 to 8.0 v v Electric conductivity (25C) [S/cm] 100* to 300* v v Chloride ion (Cl) [mg/L] 50 or less v Sulfuric acid ion (SO42) [mg/L] 50 or less v 2 s Min. 1 s Standard item 0.5 s 0.2 s Acid consumption amount (at pH4.8) [mg/L] 50 or less v Total hardness [mg/L] 70 or less v Calcium hardness (CaCO3) [mg
Applicable flange size Applicable tubing size (mm) 2 4 4 5 5 5 6 6 6 Size Symbol Applicable flange size Applicable tubing size (inch) 2 4 4 5 5 5 6 6 6 10K-20A 10K-20A 10K-25A 10K-15A 10K-20A 10K-25A 10K-20A 10K-25A 10K-40A 10K-20A 10K-20A 10K-25A 10K-15A 10K-20A 10K-25A 10K-20A 10K-25A 10K-40A 6 x 4 1/4" x 5/32" 2 2 3 1 2 3 2 3 4 B B C A B C B C D LVW 12 x 10 1/2" x 3/8" LQ1 19 x 16 3/4"
Tightening Torque for Piping Connection thread Rc1/4 Rc3/8 Rc1/2 Rc3/4 Rc1 Rc1 1/2 Rc2 Rc2 1/2 Rc3 Proper tightening torque Nm 12 to 14 22 to 24 28 to 30 28 to 30 36 to 38 40 to 42 48 to 50 48 to 50 48 to 50 4. When connecting piping to a product Avoid mistakes regarding the supply port etc. 5.
Type 2 VNC 15A 1 1 1 A T Actuators Manual override Valve size Valve type Port size Rated voltage Symbol Nil Air operated type Port size Rc Valve size 1 Orifice size (mm) Symbol 1 2 4 2 200VAC, 50/60Hz 1 100VAC, 50/60Hz Symbol N.C. 0.5MPa N.O. 1MPa N.C. 1MPa 3 110VAC, 50/60Hz 4 220VAC, 50/60Hz 1 6A 8A 10A 10A 15A 20A 25A 32A 1/8 1/4 3/8 3/8 1/2 3/4 7 5 24VDC 6 12VDC 7 240VAC, 50/60Hz 15
Function 1 2 3 4 5 6 100VAC (50/60Hz) 200VAC (50/60Hz) 110VAC (50/60Hz) 220VAC (50/60Hz) 24VDC 12VDC Standard type (1W) Energy saving type (0.5W) External pilot Nil Y Note 1) Seal type R Note 2) Metal seal Rubber seal 0 1 1 2 3 Stations D side U side Note1) Applicable to DC specifications. Note2) See page 35 for details on external pilot specifications.
/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Other VC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Other Nil S Z None With surge voltage suppressor With light/surge voltage suppressor With indicator light Option VDW L Light/Surge voltage suppressor Nil Z VQ Except 12 VDC, 240 VAC, other voltages
1 pc. (4) Barrel nipple 25A 1 pc.
Applicable piping size Applicable tubing size (inch) 2 4 4 5 5 5 6 6 6 2 2 3 1 2 3 2 3 4 B B C A B C B C D 6 x 4 10K-20A 10K-20A 10K-25A 10K-15A 10K-20A 10K-25A 10K-20A 10K-25A 10K-40A 1/4" x 5/32" 10K-20A 10K-20A 10K-25A 10K-15A 10K-20A 10K-25A 10K-20A 10K-25A 10K-40A 12 x 10 1/2" x 3/8" 19 x 16 3/4" x 5/8" 25 x 22 1" x 7/8" Dimensions Union Flange: LQ3F Metric Size (S) T P M L2 L2 L1 L1