SMC Corporation of America
Elite Part Number Search
Search Results "25A-CDBQ2B63-50DCM-HN-M9BWL"

Magnet: Built-in, Mounting: Through Hole [Standard], Bore Size: Ø63 mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 75mm, Body Option: Rubber Bumper, Rod End Female Thread, Lock Position: Rear Locking, Release of Manual: Non-locking Type, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Through Hole [Standard], Bore Size: Ø63 mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 75mm, Body Option: Rubber Bumper, Rod End Male Thread, Lock Position: Rear Locking, Release of Manual: Non-locking Type, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: -, Valves: -, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: -, Valves: -, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: -, Valves: -, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 35, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: -, Valves: -, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in

Magnet: D (Built-in), Mounting: B (Through Hole [Standard]), Bore Size: 40mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 50mm, Body Option: M (Rod End Male Thread), Lock Position: H (Head End Lock), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m)

Magnet: Built-in, Mounting: Through Hole [Standard], Bore Size: 40mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 50mm, Body Option: Rod End Male Thread, Lock Position: Head End Lock, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 3m

Magnet: D (Built-in), Mounting: B (Through Hole [Standard]), Bore Size: Ø63 mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 15mm, Body Option: CM (Rubber Bumper, Rod End Male Thread), Lock Position: H (Rear Locking), Release of Manual: N (Non-locking Type), Auto Switch: M9BAV--Solid State, Water Resist., 2 Wire, Vertical, Lead Wire or Prewired Connector: L (3 m)

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: -, Valves: -, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: -, Valves: -, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in

Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, single rod, end lock, Bore size *: 20, 25, 32, 40, 50, 63, 80, 100 , Standard stroke *: 10 through 100 , Port thread types: Rc, NPT, G , Auto switch capable, 25A-CBQ2 JPN CYLINDER, COMPACT CYLINDER, 489, 1.10000 lb

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, single rod, end lock, Bore size *: 20, 25, 32, 40,

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, single rod, end lock, Bore size *: 20, 25, 32, 40

Magnet: D (Built-in Magnet), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 16mm, Stroke: 50mm, Option: C (Rubber Bumper), Auto Switch: No Switch, Lead Wire or Prewired Connector: M (1m)

Magnet: None, Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 16mm, Stroke: 50mm, Option: C (Rubber Bumper), Auto Switch: No Switch, Lead Wire or Prewired Connector: M (1m)

Magnet: D (Built-in Magnet), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 20mm, Stroke: 50mm, Option: C (Rubber Bumper), Auto Switch: No Switch, Lead Wire or Prewired Connector: M (1m)

Magnet: Built-in Magnet, Mounting: Through Hole, Both Ends Tapped, Bore Size: 16mm, Stroke: 50mm, Option: Rubber Bumper, Auto Switch: No Switch, Lead Wire or Prewired Connector: 1m, Number: -

Magnet: None, Mounting: Through Hole, Both Ends Tapped, Bore Size: 16mm, Stroke: 50mm, Option: Rubber Bumper, Auto Switch: No Switch, Lead Wire or Prewired Connector: 1m, Number: -

Magnet: D (Built-in Magnet), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 25mm, Stroke: 50mm, Option: C (Rubber Bumper), Auto Switch: No Switch, Lead Wire or Prewired Connector: M (1m)