Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: ø1/4 One-touch Fitting, Piping Entry Direction: Bottom Side, Output Specification: 1 PNP Outputs + External Input, Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: -
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/4, Piping Entry Direction: Straight, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: -
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: -
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Bottom Side, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: M (SI Unit Only), Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover)
SMC's PFM dual color digital flow switch was developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications. The series is incredibly compact and lightweight compared to existing flow sensors. The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon
Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: None (Straight), Port Size: C6 (ø6), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: M (SI Unit Only)
Rated Flow Range: 21 (2 to 200 L/min), Flow Adjustment Valve: None (Straight), Port Size: C8 (ø8), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: M (SI Unit Only)
Size/Valve Type: 6 (Size: 25A; Valve Type: N.C.), Body/Port/Orifice: N (Body Material: C37; Port Size: 1, Orifice Dia.: 25), Voltage/Electrical Entry: Z (Other Voltages and Electrical Options), Other Voltages and Electrical Options: 2A (24VDC; DIN Terminal w/Surge Voltage Suppressor & Light), Other Options: Z (Oil-free, Rc Thread, w/One-touch Fitting), Bracket: XB (w/Bracket)
Size/Valve Type: 6 (Size: 25A; Valve Type: N.C.), Body/Port/Orifice: N (Body Material: C37; Port Size: 1, Orifice Dia.: 25), Voltage/Electrical Entry: Z (Other Voltages and Electrical Options), Other Voltages and Electrical Options: 2K (24VDC; Conduit Terminal w/Surge Voltage Suppressor & Light), Other Options: Z (Oil-free, Rc Thread, w/One-touch Fitting), Bracket: XB (w/Bracket)
SMC's new PFMB dual color digital flow switch allows for a wide range of flow measurement with one product. The PFMB is suitable for use with air and nitrogen. It's compact and space saving with an integrated flow adjustment valve. The bypass structure limits the contact of moist air with the sensor, reducing degradation of the sensor and helps maintain accuracy. 2-color display improves
SMC's PFM dual color digital flow switch was developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications. The series is incredibly compact and lightweight compared to existing flow sensors. The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon
Body Class: 2 (Class 2, Orifice ø4), Valve Type: 0 (Normally Closed), Port Size: 02 (1/4), Thread: N (NPT), Material: B (Body: PPS, Endplate: PPS, Diaphragm: PTFE), Option: 1 (Flow Rate Adjustment), Specification: V (Vacuum), Z: Z (Pilot Port Thread 1/8)
Body Class: 2 (Class 2, Orifice ø4), Valve Type: 0 (Normally Closed), Port Size: 02 (1/4), Thread: N (NPT), Material: A (Body: SUS, Endplate: PPS, Diaphragm: PTFE), Option: 1 (Flow Rate Adjustment), Specification: V (Vacuum), Z: Z (Pilot Port Thread 1/8)
Body Class: 2 (Class 2, Orifice ø4), Valve Type: 0 (Normally Closed), Port Size: 02 (1/4), Thread: N (NPT), Material: C (Body: PFA, Endplate: PPS, Diaphragm: PTFE), Option: 1 (Flow Rate Adjustment), Specification: V (Vacuum), Z: Z (Pilot Port Thread 1/8)
Size: 21 (1/8), Model Combination: B (AF+AR), Port Size: 02 (1/4, Size 21), Accessory: None, All Sizes, Pressure Relief Valve: V (Downstream Valve), Option: 2 (Metal Bowl, Flow Direction: Left to Right; Size 21), Handle Orientation: A (Upward Handle)
Size: 21 (1/8), Model Combination: B (AF+AR), Port Size: 02 (1/4, Size 21), Accessory: None, All Sizes, Pressure Relief Valve: V (Downstream Valve), Option: 2R (Metal Bowl, Flow Direction: Right to Left, Size 21), Handle Orientation: A (Upward Handle)
Body Size: 20, Thread: Rc, Port Size: 02 (1/4), Option: C (N.C. Float Type Auto Drain), Attachment: V1 (3-Port Valve for Residual Pressure Release; Mounting: V+AF+AR), Semi-Standard 1: Standard, Semi-Standard 2: R (Flow Direction: Right to Left)
Body Size: 30, Thread: N (NPT), Port Size: 02 (1/4), Option: DG (D + G), Attachment: TV (T + V), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 20, Thread: N (NPT), Port Size: 02 (1/4), Option: Standard, Attachment: SV (S + V), Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)