Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: 3 (External Stopper: 90°), Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3), Controller Type - LEC, JXC: 1N (LECP1, Programless Type, NPN), I/O Cable Length for LEC: 3 (3)
Rotation Torque: K (High Torque, LER10: 0.3; LER30: 1.2; LER50: 10), Rotation Angle: 3 (External Stopper: 90°), Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3), Controller Type - LEC, JXC: 1N (LECP1, Programless Type, NPN), I/O Cable Length for LEC: 3 (3)
Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5), Controller Type - LEC, JXC: 1N (LECP1, Programless Type, NPN), I/O Cable Length for LEC: 1 (1.5)
Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: L (Entry on the Left Side), Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5), Controller Type - LEC, JXC: 1N (LECP1, Programless Type, NPN), I/O Cable Length for LEC: 1 (1.5)
Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: 2 (External Stopper: 180°), Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3), Controller Type - LEC, JXC: 1N (LECP1, Programless Type, NPN), I/O Cable Length for LEC: 3 (3)
Body Size: 10, Motor Size: L (Compact), Stroke: 4mm, Finger Option: B (Through-hole in Opening/Closing Direction), Motor Cable Entry: Basic, Entry on the Left Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5m), Controller Type - LEC, JXC: 1N (LECP1, Programless Type, NPN), I/O Cable Length for LEC: 1 (1.5m), Controller Mounting: D (DIN Rail)
Body Size: 10, Motor Size: Standard, Stroke: 4mm, Finger Option: B (Through-hole in Opening/Closing Direction), Motor Cable Entry: F (Entry on the Front Side), Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5m), Controller Type - LEC, JXC: 1N (LECP1, Programless Type, NPN), I/O Cable Length for LEC: 3 (3m), Controller Mounting: D (DIN Rail)
Size: 10, Motor Size: Standard, Lead Screw Type, mm: K (LEP*6: 4; LEP*10: 5), Stroke: 50mm, Motor Cable Mounting Direction: L (Entry on Left Side), Actuator Cable Type: S (Standard Cable), Actuator Cable Length, m: 1 (1.5), Controller Type - LEC, JXC: 1N (LECP1, Programless Type, NPN), I/O Cable Length for LEC: 1 (1.5)
.: 10), Voltage/Electrical Entry: Z (Other Voltages and Electrical Options), Other Voltages and Electrical Options: 1N (12VDC; Conduit Terminal w/Surge Voltage Suppressor), Other Options: B (NPT Thread), Bracket: XB (w/Bracket)
.: 10), Voltage/Electrical Entry: Z (Other Voltages and Electrical Options), Other Voltages and Electrical Options: 1N (12VDC; Conduit Terminal w/Surge Voltage Suppressor), Other Options: B (NPT Thread), Bracket: XB (w/Bracket)
Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 400mm, Motor Option: None, Rod End Thread: Female, Mounting: L (Foot), Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5m), Controller Type - LEC, JXC: 1N (LECP1, NPN, Programless Type)
Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 100mm, Motor Option: None, Rod End Thread: M (Male), Mounting: D (Double Clevis), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: 1N (LECP1, NPN, Programless Type)
Size: 25, Motor Mounting Position: U (Bottom Mounting), Stroke: 300, Motor Option: w/o Option, Stroke Adjustment Unit: W (Both Sides), Actuator Cable Type: S (Standard Cable), Actuator Cable Length: 1 (1.5m), Controller Type - LEC, JXC: 1N (LECP1, Programless Type, NPN), I/O Cable Length for LEC: w/o Cable, Controller Mounting: D (DIN Rail Mounting)
Size: 25, Motor Mounting Position: L (Left), Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 250mm, Motor Option: None, Rod End Thread: Female, Mounting: L (Foot), Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: 1N (LECP1, NPN, Programless Type)
Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 400mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: 1N (LECP1, NPN, Programless Type)
Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 500mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: 1N (LECP1, NPN, Programless Type)
Electrical entry: grommet, type D DIN connector, type Y DIN connector, VALVE, SOFT START 3/4, JPN SPL, VALVE, AV SOFT START UP BODY PORT, KA, AV BODY PORT 3/4 NPT, 3.98637 lb, ModelPort sizeProof pressureOperating pressure rangePressure gauge port sizeAmbient and fluid temperatureEffective area (mm2)Mass (kg)Electrical specificationsPilot valve manual override1(P) 2(A)2(A) 3(R)
Series AM can separate and remove oil mist in compressed air, which is difficult to remove by ordinary air filters and removes solid particles such as rust or carbon of more than 0.3 micron. It is the most suitable for air sources that drive pilot, metal seal solenoid valves. Mist separator, possible modular connection, Dust filtration, oil mist separation , Nominal filtration rating: 0.3
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FILTER, MODULAR, AIRLINE EQUIPMENT, AF MASS PRO, GA, AF MASS PRO 3/4 MODULAR (PT), 1.35520 lb, ModelPort sizeFluidAmbient and fluid temperatureProof pressureMaximum operating pressureNominal filtration ratingDrain capacity (cm3)Bowl materialBowl guardMass (kg)AF401/4, 3/8, 1/2Air?5 to 60C (with no
This combination Filter/ Regulator minimizes space and piping by integrating the 2 units into one. Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc. The AW is part of the family of modular air preparation units and