Model: 2000, Output Pressure: 0.9MPa, Terminals: Conduit, Thread: NPTF, Input Signal: 0~10VDC, Port Size: 2 [1/4" (2000,4000)], Accessory: Bracket, Pressure Gauge: Indication of psi and k
Model: 2000, Output Pressure: 0.1MPa, Terminals: Conduit, Thread: NPTF, Input Signal: 4~20mA, Port Size: 2 [1/4" (2000,4000)], Accessory: Bracket, Pressure Gauge: Indication of psi and k
Model: 2000, Output Pressure: 0.5MPa, Terminals: Conduit, Thread: NPTF, Input Signal: 4~20mA, Port Size: 2 [1/4" (2000,4000)], Accessory: Bracket, Pressure Gauge: Indication of psi and k
Model: 2000, Output Pressure: 0.35MPa, Terminals: Conduit, Thread: NPTF, Input Signal: 4~20mA, Port Size: 3 [3/8" (2000,4000)], Accessory: Bracket, Pressure Gauge: Indication of psi and k
Model: 2000, Output Pressure: 0.35MPa, Terminals: Conduit, Thread: NPT, Input Signal: 0~10VDC, Port Size: 3 [3/8" (2000,4000)], Accessory: Bracket, Pressure Gauge: Indication of psi and k
Model: 2000, Output Pressure: 0.7MPa, Terminals: Conduit, Thread: NPT, Input Signal: 4~20mA, Port Size: 3 [3/8" (2000,4000)], Accessory: Bracket, Pressure Gauge: Indication of k and psi
Model: 2000, Output Pressure: 0.7MPa, Terminals: Conduit, Thread: NPT, Input Signal: 0~5VDC, Port Size: 2 [1/4" (2000,4000)], Accessory: Bracket, Pressure Gauge: Indication of psi and k
Model: 2000, Output Pressure: 0.5MPa, Terminals: Conduit, Thread: NPT, Input Signal: 0~10VDC, Port Size: 2 [1/4" (2000,4000)], Accessory: Bracket, Pressure Gauge: Indication of psi and k
Model: 2000, Output Pressure: 0.35MPa, Terminals: Conduit, Thread: NPT, Input Signal: 0~10VDC, Port Size: 2 [1/4" (2000,4000)], Accessory: Bracket, Pressure Gauge: Indication of psi and k
Model: 2000, Output Pressure: 0.1MPa, Terminals: Conduit, Thread: NPT, Input Signal: 0~10VDC, Port Size: 2 [1/4" (2000,4000)], Accessory: Bracket, Pressure Gauge: Indication of psi and k
Model: 2000, Output Pressure: 0.5MPa, Terminals: Conduit, Thread: NPT, Input Signal: 0~10VDC, Port Size: 2 [1/4" (2000,4000)], Accessory: None, Pressure Gauge: Indication of psi and k
Model: 2000, Output Pressure: 0.1MPa, Terminals: Conduit, Thread: NPT, Input Signal: 0~10VDC, Port Size: 3 [3/8" (2000,4000)], Accessory: None, Pressure Gauge: Indication of k and psi
Size: 1/8, Thread: NPT, Port Size: 1/8, Accessory: None, Option 1: Drain Cock, Option 2: CZ [Bowl Guard (Size 2000 Only)+Name Plate, Caution on Bowl]
Size: 1/8, Thread: NPT, Port Size: 1/8, Accessory: Bracket, Option 1: Drain Cock, Option 2: CZ [Bowl Guard (Size 2000 Only)+Name Plate, Caution on Bowl]
Size: 1/8, Thread: NPT, Port Size: 1/4, Accessory: None, Option 1: Drain Cock, Option 2: CZ [Bowl Guard (Size 2000 Only)+Name Plate, Caution on Bowl]
Size: 1/8, Thread: NPT, Port Size: 1/4, Accessory: Bracket, Option 1: Drain Cock, Option 2: CZ [Bowl Guard (Size 2000 Only)+Name Plate, Caution on Bowl]
Size: 1/8, Thread: F [G(PF)], Port Size: 1/4, Accessory: None, Attachment: None, Option 1: None, Option 2: C [Bowl Guard (Size 2000 Only)], Option 3: -
Size: 1/8, Thread: F [G(PF)], Port Size: 1/8, Accessory: None, Attachment: None, Option 1: None, Option 2: C [Bowl Guard (Size 2000 Only)], Option 3: -
For VQC1000/2000 series valves, install valves with the same common specification as the common specification of your protocol.
③ Manifolds with kits other than the serial transmission kit (“S”), which includes options “F,” “L,” “M,” “P,” and “T,” do not have common polarity. Therefore, it is acceptable to mount either VQC1000/2000 positive common or negative common valves.
Electro-Pneumatic Regulator ITV1000/2000/3000 Series with 2 possible directions of cable entry.Features· Stepless control of air pressure in proportion to an electric signal.· Sensitivity: 0.2 kPa (100 kPa specification).· Linearity: within ±1% (F.S.)· Hysteresis: within 0.5% (F.S.)· Protective structure: IP65.· 2 possible directions of cable entry.· Grease-free specification (ITV1000 Series