Model: 10S3 (Side Ported), SI Unit Specification: V (CC-Link), Valve Stations: 8 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block Assembly: S (Internal Pilot/Built-in Silencer), A, B Port Size: C6 (ø6 One-touch Fitting)

Model: 11S3 (Bottom Ported), SI Unit Specification: V (CC-Link), Valve Stations: 8 Stations, P, E Port Location: D (D Side), SUP/EXH Block Assembly: S (Internal Pilot/Built-in Silencer), A, B Port Size: C6 (ø6 One-touch Fitting)

Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N1 (NPT1/8), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: V (Panel Mount Adapter, w/Flow Adjustment Valve)

Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N2 (NPT1/4), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: V (Panel Mount Adapter, w/Flow Adjustment Valve)

Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C8 (ø8), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: V (Panel Mount Adapter, w/Flow Adjustment Valve)

Rated Flow Range: 21 (2 to 200 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N2 (NPT1/4), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: V (Panel Mount Adapter, w/Flow Adjustment Valve)

Part Number Description: E/P CONTROL VALVE 3/8 NPT   Product Line: V   Product Line Description: VALVE   Family Code: 313   Family Description: VER PROPORTIONAL VALVE   Class Code: QD   Part Code: 1   Reference Code:  K   Click here to report information errorImage shown may not match exact part number, E/P CONTROL VALVE 1/2 NPT, VALVE, VER PROPORTIONAL VALVE, QD, VER BASE MT 3/8,

Please contact us for the latest version.sales@ocaire.com, GP-40-V W/SIDE MOUNTING, ACTUATOR, GRIPPER, NC, 50MM GRIPPER, .00000 lb

Rated Flow Range: 21 (2 to 200 L/min), Flow Adjustment Valve: W (With Flow Adjustment Valve, Rear Ported), Port Size: C8 (ø8), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector)

Rated Flow Range: 21 (2 to 200 L/min), Flow Adjustment Valve: W (With Flow Adjustment Valve, Rear Ported), Port Size: C8 (ø8), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector)

Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: C6 (ø6), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: N (w/o Lead Wire w/Connector)

Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: None (Straight), Port Size: C8 (ø8), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: N (w/o Lead Wire w/Connector)

Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: None (Straight), Port Size: C6 (ø6), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: N (w/o Lead Wire w/Connector)

Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: G (Round Type Pressure Gauge w/Limit Indicator), Attachment: V (3-Port Valve for Residual Pressure Release; Mounting: AF+AR+V), Semi-Standard 1: Standard, Semi-Standard 2: NRWZ (N + R + W + Z)

The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., DIGITAL PRESSURE SWITCH, PRESSURE SWITCH, ISE1-6, N59, 120.00000 lb

The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., DIGITAL PRESSURE SWITCH, PRESSURE SWITCH, ISE1-6, N59, 120.00000 lb

The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., DIGITAL PRESSURE SWITCH, PRESSURE SWITCH, ISE1-6, N59, 120.00000 lb

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 09 [ø5/16 One-touch Fitting (Inch)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow