SMC Corporation of America
Elite Part Number Search
Search Results "CYP15-100S-Y7BW"

0.5 (Nil) Applicable load 3 (L) 5 (Z) AC DC 5V Z76 3 wire IC circuit Reed switch Yes Grommet Z73 12V 100V 2 wire 24V Relay, PLC Z80 IC circuit No 100V or less 5, 12V Y59A 3 wire (NPN) 5, 12V IC circuit 3 wire (PNP) Y7P Solid state switch Y59B 2 wire 12V Grommet Relay, PLC Yes 24V Y7NW 3 wire (NPN) Diagnostic indication (2 color indicator) 5, 12V IC circuit Y7PW 3 wire (PNP) Y7BW

How to Order Standard L 40 150 CA2Y L Y7BW S 40 150 CDA2Y With auto switch Number of auto switches With auto switch (Built-in magnet) 2 pcs. 1 pc. 3 pcs. n pcs. Nil S 3 n Mounting B L F G C D T Basic Axial foot Front flange Rear flange Single clevis Double clevis Center trunnion Auto switch Nil Without auto switch Please select the applicable auto switch model from the table below.

Applicable model Applicable load Pre-wire connector In-line 0.5 (Nil) 3 (L) DC AC Load voltage Auto swich model Electrical entry Flexible lead wire (2) (-61) Electrical entry Indicator light Wiring (Output) Special function Type 5 (Z) 10 16 20 25 Perpendicular Y69A M9NV F8N Y7PV M9PV F8P Y69B M9BV F8B Y7NWV F9NWV Y7PWV F9PWV Y7BWV F9BWV Y59A M9N Y7P M9P Y59B M9B Y7NW F9NW Y7PW F9PW Y7BW

For details about auto switches with pre-wire connector, refer to page 915-66. 3-wire (NPN) Y7NW 24 V 5 V, 12 V Diagnostic indication (2-color indication) 3-wire (PNP) Y7PW Y7BW Grommet 2-wire 12 V Water resistant (2-color indication) Y7BA With diagnostic output (2-color indication) 4-wire (NPN) F59F 5 V, 12 V IC circuit Lock Unit/Applicable Auto Switch Lead wire length symbols: 0.5 m Nil

[] [] [] [] [] [] M9NV M9N 3-wire (NPN) [Y69A] [Y59A] 5V, 12V IC circuit M9PV M9P Solid state switch Reed switch 3-wire (PNP) [Y7PV] [Y7P] M9BV M9B 2-wire 12V [Y69B] [Y59B] M9NW Relay, PLC 24V Grommet Yes M9NWV 3-wire (NPN) [Y7NWV] [Y7NW] 5V, 12V IC circuit Diagnostic indication (2-color indication) M9PWV M9PW 3-wire (PNP) [Y7PWV] [Y7PW] M9BWV M9BW 2-wire 12V [Y7BWV] [Y7BW

(Tightening torque of M4 screw should be 1 to 1.2 Nm.) 13 < Applicable Auto switches > Solid state auto switch D-Y59A/BY69A/BY7P(V) D-Y7NW(V)Y7PW(V)Y7BW(V) D-Y7BAL Reed auto switch D-Z73Z76Z80 Fig.6 Mounting and movement of the auto switch (1) Fix it to the detecting position with a set screw by installing an auto switch mounting bracket in cylinder tie-rod and letting the bottom surface

Auto switch type Model Features Electrical entry (Fetching direction) D-Z73, Z76 Grommet (In-line) Reed Without indicator light D-Z80 D-Y69A, Y69B, Y7PV Grommet (Perpendicular) Diagnostic indication (2-color) D-Y7NWV, Y7PWV, Y7BWV Solid state D-Y59A, Y59B, Y7P Grommet (In-line) Diagnostic indication (2-color) D-Y7NW, Y7PW, Y7BW For solid state auto switches, auto switches with a pre-wired

Applicable model Applicable load Pre-wire connector In-line 0.5 (Nil) 3 (L) DC AC Load voltage Auto swich model Electrical entry Flexible lead wire (2) (-61) Electrical entry Indicator light Wiring (Output) Special function Type 5 (Z) 10 16 20 25 Perpendicular Y69A M9NV F8N Y7PV M9PV F8P Y69B M9BV F8B Y7NWV F9NWV Y7PWV F9PWV Y7BWV F9BWV Y59A M9N Y7P M9P Y59B M9B Y7NW F9NW Y7PW F9PW Y7BW

(Tightening torque of M5 screw should be 2 to 3 Nm.) (5) Modification of the detecting position should be made in the condition of 3. 14 < Applicable Auto switches > Solid state auto switch D-Y59A/BY69A/BY7P(V) D-Y7NW(V)Y7PW(V)Y7BW(V) D-Y7BAL Reed auto switch D-Z73Z76Z80 Fig. 7 Mounting and movement of the auto switch (1) Fix it to the detecting position with a set screw by installing an

entry Applicable load 0.5 (Nil) 3 (L) 5 (Z) AC DC Z76 3 wire 5V IC circuit Yes Reed switch Z73 100V Grommet 12V 24V 2 wire Relay, PLC Z80 No 100V or less 5, 12V IC circuit Y59A 3 wire (NPN) IC circuit 5, 12V Y7P 3 wire (PNP) Solid state switch Y59B 12V 2 wire Yes Relay, PLC Grommet 24V Y7NW 3 wire (NPN) Diagnostic indication (2 color indicator) IC circuit 5, 12V Y7PW 3 wire (PNP) Y7BW

Type Electrical entry Features Series C85 Series CP96 Series C96 Series C55 D-M9NV, M9PV, M9BV D-Y69A, Y69B, Y7PV D-M9NWV, M9PWV, M9BWV Grommet (Perpendicular) Diagnostic indication (2-color indication) D-Y7NWV, Y7PWV, Y7BWV D-M9NAV, M9PAV, M9BAV Water resistant (2-color indication) D-Y59A, Y59B, Y7P Sold state D-F59, F5P, J59 D-Y7NW, Y7PW, Y7BW Diagnostic indication (2-color indication

Lead wire lingth(m) Load voltage Auto switch model Indicator light Wiring (Output) Electrical entry Pre-wire connector Applicable load Tie-rod mounting Band mounting 0.5 (Nil) 3 (L) 5 (Z) Special function Type AC DC 3-wire (NPN equivalent) IC circuit 5 V Z76 Z73 A54 A33C A34C A44C A59W Y59A Y7P J51 Y59B G39C K39C Y7NW Y7PW Y7BW Y7BA F59F P5DW B53 B54 A33 A34 A44 B59W G59 G5P K59 G39 K39

D-F59/F5P/J51/J59 Grommet 11-11-22 D-S991/S992/S99V1/S99V2 11-11-22 D-T991/T992/T99V1/T99V2 11-11-22 D-S9P1/S9P2/S9PV1/S9PV2 Grommet 11-11-23 D-S791/S792 11-11-23 D-T791/T792 Direct 11-11-23 D-S7P1/S7P2 11-11-23 Connector D-T791C/T792C 11-11-30 D-F8N/F8P/F8B D-M9N/M9P/M9B D-M9NV/M9PV/M9BV D-Y59A/Y7P/Y59B D-Y69A/Y7PV/Y69B 11-11-31 Grommet 11-11-24 D-F79W/F7PW/J79W Rail Grommet D-Y7NW/Y7PW/Y7BW

Electrical entry direction Electrical entry Wiring (Output) Special function Type DC AC Perpendicular In-line Z76 5V 100V 3-wire IC circuit Grommet Yes Reed switch Z73 Z80 12V Relay, PLC 2-wire 24V 5V, 12V 100V or less No IC circuit 3-wire (NPN) Y59A Y69A 5V 12V 12V 5V 12V IC circuit 3-wire (PNP) Y7PV Y7P 2-wire Y59B Y69B Relay, PLC Solid state switch Y7NWV Y7PWV Y7BWV Y7NW Y7PW Y7BW

Lead wire lingth(m) Auto switch model Load voltage Indicator light Wiring (Output) Electrical entry Pre-wire connector Applicable load Tie-rod mounting Band mounting 0.5 (Nil) 3 (L) 5 (Z) Special function Type AC DC 3-wire (NPN equivalent) IC circuit 5 V Z76 Z73 A54 A33C A34C A44C A59W Y59A Y7P J51 Y59B G39C K39C Y7NW Y7PW Y7BW Y7BA F59F P5DW B53 B54 A33 A34 A44 B59W G59 G5P K59 G39 K39

(Tightening torque of M4 screw should be 1 to 1.2 Nm.) 13 < Applicable Auto switches > Solid state auto switch D-Y59A/BY69A/BY7P(V) D-Y7NW(V)Y7PW(V)Y7BW(V) D-Y7BAL Reed auto switch D-Z73Z76Z80 Fig.6 Mounting and movement of the auto switch (1) Fix it to the detecting position with a set screw by installing an auto switch mounting bracket in cylinder tie-rod and letting the bottom surface

Electrical entry Features D-M9NV, M9PV, M9BV D-Y69A, Y69B, Y7PV D-M9NWV, M9PWV, M9BWV Diagnostic indication (2-color indicator) D-Y7NWV, Y7PWV, Y7BWV Grommet (Perpendicular) D-M9NAV, M9PAV, M9BAV Water-resistant (2-color indicator) D-Y59A, Y59B, Y7P D-F59, F5P, J59 Solid state D-Y7NW, Y7PW, Y7BW Diagnostic indication (2-color indicator) D-F59W, F5PW, J59W Grommet (In-line) D-F5BA, Y7BA

indicator light Reed CEP1 D-A53, A56, B53, Z73, Z76 Grommet (In-line) D-A67, Z80 Without indicator light CE1 D-M9NV, M9PV, M9BV D-Y69A, Y69B, Y7PV Grommet (Perpendicular) CE2 CE2 D-M9NWV, M9PWV, M9BWV Diagnostic indication (2-color indicator) D-Y7NWV, Y7PWV, Y7BWV ML2B Water resistant (2-color indicator) D-M9NAV, M9PAV, M9BAV Solid state D-Y59A, Y59B, Y7P D-F59, F5P, J59 D-Y7NW, Y7PW, Y7BW

D-Y7NW(V)/D-Y7PW(V)/D-Y7BW(V) Direct Mounting Style ... 2-color Indication Type with Diagnostic Output. D-F79F Rail Mounting Style. Water Resistant 2-color Indication Type. D-F7BA(V)L Water Resistant Rail Mounting Style . D-F9BAL Water Resistant Direct Mounting Style . D-Y7BAL Water Resistant Direct Mounting Style . Solid State Switch with Timer . D-F7NTL Rail Mounting Style .

Auto switch type Model Features Electrical entry (Fetching direction) Applicable bore size D-Z73, Z76 Reed Grommet (In-line) MGC Without indicator light D-Z80 D-Y69A, Y69B, Y7PV Grommet (Perpendicular) MGF 40 to 80 D-Y7NWV, Y7PWV, Y7BWV Diagnostic indication (2-color indication) Solid state D-Y59A, Y59B, Y7P MGZ Grommet (In-line) Diagnostic indication (2-color indication) D-Y7NW, Y7PW, Y7BW