Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: 04 [Vacuum: 2 x Rc1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Vertical Connector w/o Connector),
Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N04 [Vacuum: 2 x NPT1/2 (Branch Spec.); Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Vertical Connector w/o Connector
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for de-ionized water and chemicals , Remote type sensor unit , Flow rate range: 0.4 to 4 l/min ~ 4 to 40 l/min , Output for display unit with or w/o analog output , Port sizes: 3/8", 1/2", 3/4", PFD NO SIZE (MISC./OTHER), INSTRUMENTATION, PFD DIGITAL FLOW SWITCH, 2X, PFD NO SIZE (MISC.
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for de-ionized water and chemicals , Remote type sensor unit , Flow rate range: 0.4 to 4 l/min ~ 4 to 40 l/min , Output for display unit with or w/o analog output , Port sizes: 3/8", 1/2", 3/4", DIGITAL FLOW SWITCH, INSTRUMENTATION, PFD DIGITAL FLOW SWITCH, 2X, PFD NO SIZE (MISC.
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: L (Out 1: IO-Link: Switch Output, N/P, Out 2: None; Temperature Sensor ), Temperature Sensor: T (Temperature Sensor), Lead Wire: Q (w/M12-M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket
Accuracy: Basic, Motor Mounting Position: L (Left Side Parallel), Motor Type: T8 [AC Servo Motor, (Absolute Encoder), 400W], Lead: L (2.86mm), Stroke: 400mm, Dust/Drip Proof: P (IP65, Dust/Drip Proof Specification w/vent hole tap), Motor Option: B (w/Lock), Rod End Thread: Rod End Female Thread, Mounting: L (Foot)
Accuracy: H (High Precision), Motor Mounting Position: L (Left Side Parallel), Motor Type: S4 [AC Servo Motor, (Incremental Encoder), 400W], Lead: L (2.86mm), Stroke: 150mm, Dust/Drip Proof: P (IP65, Dust/Drip Proof Specification w/vent hole tap), Motor Option: B (w/Lock), Rod End Thread: Rod End Female Thread, Mounting: L (Foot), Cable Type: R (Robotic Cable, Flexible Cable), Cable Length
Accuracy: Basic Type, Size: 63, Motor Mounting Position: L (Left Side Parallel), Motor Type: NT (Mounting Type T), Lead Screw: L (LEY63, 2.86], Stroke: 400mm, Dust/Drip Proof: P (IP65, Dust/Drip Proof Specification w/Vent Hole Tap), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: L (Foot)
Accuracy: Basic Type, Size: 63, Motor Mounting Position: L (Left Side Parallel), Motor Type: NZ (Mounting Type Z), Lead Screw: L (LEY63, 2.86], Stroke: 400mm, Dust/Drip Proof: P (IP65, Dust/Drip Proof Specification w/Vent Hole Tap), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: L (Foot)
AMX-OMZ0092 PRODUCT NAME Line Filter MODEL / Series / Product Number AFF50-(F,N)06 ~ (F,N)10(B,C,D)(-J,L,R,W,Z)-D AFF60-(F,N)10(B,C,D)(-J,L,R,W,Z)-D Contents Page 1. Safety Instructions 2 to 6 2. Application 7 3. Standard specifications 7 4. How to Order 8 5. Construction / Options / Replacement parts 9 6. Bowl assembly specifications 10 to 11 6-1. Bowl assembly for AFF50 10 6-2.
AMX-OMZ0093 PRODUCT NAME Mist Separator MODEL / Series / Product Number AM50-(F,N)06 ~ (F,N)10(B,C,D)(-J,L,R,W,Z)-D AM60-(F,N)10(B,C,D)(-J,L,R,W,Z)-D Contents Page 1. Safety Instructions 2 to 6 2. Application 7 3. Standard specifications 7 4. How to Order 8 5. Construction / Options / Replacement parts 9 6. Bowl assembly specifications 10 to 11 6-1. Bowl assembly for AM50 10 6-2.
AMX-OMZ0094 PRODUCT NAME Micro Mist Separator MODEL / Series / Product Number AMD50-(F,N)06 ~ (F,N)10(B,C,D)(-J,L,R,W,Z)-D AMD60-(F,N)10(B,C,D)(-J,L,R,W,Z)-D Contents Page 1. Safety Instructions 2 to 6 2. Application 7 3. Standard specifications 7 4. How to Order 8 5. Construction / Options / Replacement parts 9 6. Bowl assembly specifications 10 to 11 6-1.
Danger: Switch ON At normal output Switch OFF
Grease pack part no.: GR-L-005 (5 g), GR-L-010 (10 g), GR-L-150 (150 g) 30
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for air applications , Integrated display type , Flow rate range: 1-10(l/min) ~ 50-500(l/min) , Output for display unit with or w/o analog output , Port sizes: 1/8, 1/4, 3/8, 1/2, DIGITAL FLOW SW, REMOTE SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, EA, IF/PFA 3/8 INCH PT VERSION, .97118 lb, ModelMeasured
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for air applications , Integrated display type , Flow rate range: 1-10(l/min) ~ 50-500(l/min) , Output for display unit with or w/o analog output , Port sizes: 1/8, 1/4, 3/8, 1/2, DIGITAL FLOW SW, REMOTE SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, EA, IF/PFA 3/8 INCH PT VERSION, .93440 lb, ModelMeasured
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for air applications , Integrated display type , Flow rate range: 1-10(l/min) ~ 50-500(l/min) , Output for display unit with or w/o analog output , Port sizes: 1/8, 1/4, 3/8, 1/2, DIGITAL FLOW SW, REMOTE SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, EA, IF/PFA 3/8 INCH PT VERSION, 1.02259 lb, ModelMeasured
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for air applications , Integrated display type , Flow rate range: 1-10(l/min) ~ 50-500(l/min) , Output for display unit with or w/o analog output , Port sizes: 1/8, 1/4, 3/8, 1/2, DIGITAL FLOW SW, REMOTE SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, EA, IF/PFA 3/8 INCH PT VERSION, .74701 lb, ModelMeasured
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for air applications , Integrated display type , Flow rate range: 1-10(l/min) ~ 50-500(l/min) , Output for display unit with or w/o analog output , Port sizes: 1/8, 1/4, 3/8, 1/2, DIGITAL FLOW SW, REMOTE SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, EX, IF/PFA 3/8 INCH ALL OTHERS, 1.15742 lb, ModelMeasured
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for air applications , Integrated display type , Flow rate range: 1-10(l/min) ~ 50-500(l/min) , Output for display unit with or w/o analog output , Port sizes: 1/8, 1/4, 3/8, 1/2, DIGITAL FLOW SW, REMOTE SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, EX, IF/PFA 3/8 INCH ALL OTHERS, 1.10231 lb, ModelMeasured