Signal Style and Part No. 3 1 AC200-220V Power supply connector 2 AC200-220V (HEC006) 3 PE 1 2 D A A AC200-220V Power supply B AC200-220V connector C Unused (HEC012) B C D PE RS-232C RS-485 5 4 3 2 1 1 Unused BUS + 2 RXD (RD) BUS Communication 3 TXD (SD) Unused connector 9 8 7 6 4 Unused Unused D-sub 9 pin (socket type) 5 SG SG Fixed screw: M2.6 6-9 Unused Unused 10-1 Appendix Description
Hs Auto switch 24.5 A B 49.5 A 33 B Proper auto switch mounting positions (mm) D-G39 D-K39 D-A3 D-A44 D-H7 D-H7C D-H7W D-H7BAL D-C7 D-C80 D-C73C D-C80C D-B5 D-B64 D-G5NTL D-H7F D-B59W Bore size (mm) A B A A A A A A B B B B B B 16 15.5 7.5 12 14 17.5 12.5 11 19 20 8 4 6 9.5 4.5 25 17.5 13.5 17 7 15.5 19 10.5 14 20.5 7.5 3.5 5.5 9 4 32 20.5 16.5 9 20 18.5 22 23.5 12.5 17 9.5 5.5 7.5 11 6 40
A B C D A B C D Bore size (mm) Port aperture A 12 (1) (1) (1) CUJ 16 (2) (2) (2) CU B D 20 (2) (2) (2) View from piston rod end 25 CQS (2) (2) (2) 32 C (2) CQM 40 (2) CQ2 50 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com (2) RQ Operating Range Auto Switch Mounting
Bit offset Item Notes 0 Distance detection SW1 0: OFF 1: ON 1 Distance detection SW2 0: OFF 1: ON 2 SUP port pressure SW1 0: OFF 1: ON 3 SUP port pressure SW2 0: OFF 1: ON 4 OUT port pressure SW1 0: OFF 1: ON 5 OUT port pressure SW2 0: OFF 1: ON 8 Pressure diagnostics 0: Normal 1: Abnormal 15 Error diagnostics 0: Normal 1: Abnormal 16 to 31 OUT port pressure gauge measurement value 16 bit
Selection Step 1. Pad selection 1-A Theoretical lifting force 1-B Calculation method: Pad diameter 2.
adjustment bolt 2-6.6 through 72 13 Adjustment: Max. 10.3 6 2-M5 x 0.8 2 8 A port 1 B port +0.030 0 3-4H9 long groove depth 3 ( A , B , C ) 8g6 0.005 0.014 16h9 0 0.043 4-M6 x 1 depth 11 50 0 0.074 53.5h9 48 9 Rotary Table High Precision Type Series MSUA These drawings indicate the condition when the B port is pressurized.
~~ , A 00) 0(0) 0 (2.5) 2(6) 4(7. 5) ~ , 40 D-AG 43.5 49 55.5 3 D-AS 1(0 1(0) 5(1.5 I O{S.5) 8(4 3t 35 42 so 57 .5 ~ Ht A 00) 00) 0(2.5 26 417 .5) D-A3 B !
8 @1 @2 w !4 !2 !5 t @0 @3 @4 @5 !9 !8 @1 @2 @6 !4 !2 !3 y !0 !1 e q @8!6 u !7 o i !3 y !0 !1 @7 r q @8 !6 u !7 o i CXSJM10 CXSJL10 !6 r !9 !8 @2 @9 !7 o i !6 @4 @5 !8 r !9 @2 @9 !7 o i Piston rod B-side piston Rod cover Piston rod B-side piston Rod cover Component Parts No. Description No. Description Note Material Note Material Hard anodized Aluminum alloy Polyurethane !
A Section A-A Bolt holder (movable) B Section B-B l2 l1 ~ = 0.5 or less l1 (mm) 5 5 l2 (mm) 8.4 9.5 CXSJ6 CXSJ10 Warning 1. Take precautions when your hands are near the plate and housing. Take sufficient care to avoid getting your hands or fingers caught when the cylinder is operated. Piping 1. Plug the appropriate supply port(s) according to the operating conditions.
Description Side cover Bearing retainer Bumper End cover A End cover B Inner cover Motor cover A Motor cover B Auto switch Magnet Brake Material Note 200W Ball screw/Slide screw 1 2 3 4 5 6 7 8 9 10 11 No.
8 @1 @2 w !4 !2 !5 t @0 @3 @4 @5 !9 !8 @1 @2 @6 !4 !2 !3 y !0 !1 e q @8!6 u !7 o i !3 y !0 !1 @7 r q @8 !6 u !7 o i CXSJM10 CXSJL10 @9 !7 o i !6 r !9 !8 @2 @9 !7 o i !6 @4 @5 !8 r !9 @2 Piston rod B-side piston Rod cover Piston rod B-side piston Rod cover Parts List: Standard Piping No. Description Material No.
Normal output Reversed output P_1 = A (A B)/4 n_1 = B + (A B)/4 A = Maximum pressure H_1 = (A B)/2 H_1 = (A B)/2 B = Minimum pressure In the OUT2 setting, the above P_1, n_1 and H_1 will be P_2, n_2 and H_2 respectively.
Grommet: G Conduit: C Approx. 300 Approx. 280 D D Q F Q F C C G (PF) 1/2 R R E E A H 2-P Port size 2-M B B A H 2-P Port size 2-M L L K K DIN connector: D Conduit terminal: T Cable 6.8 to 10 27.5 F F Q (Q) S 34 25 U R C R C (44) G (PF) 1/2 E B A H D 2-P Port size (S) E G (PF) 1/2 B A H D 2-M 2-P Port size 2-M L L K K N.C.
Suction Verification High Vacuum Suction Work 1 Work 2 Work n Max. A Formula for Obtaining the Set-Value P-1 P_1 or P_2 H_1 or H_2 H-1 P_1 (P_2) = A (A-B)/4 n_1 (n_2) = B + (A-B)/4 H_1 (H_2) = (A-B)/2 n-1 Min.
Composite Center of Gravity Calculation m1 = mn = 0.88 + 4.35 + 0.795 + 0.5 = 6.525 kg 1 m1 X = x (mn x xn) 1 6.525 = (0.88 x 65 + 4.35 x 150 + 0.795 x 150 + 0.5 x 150) = 138.5 mm 1 m1 Y = x (mn x yn) 1 6.525 = (0.88 x 0 + 4.35 x 0 + 0.795 x 111 + 0.5 x 210) = 29.6 mm 1 m1 Z = x (mn x zn) 1 6.525 = (0.88 x 5 + 4.35 x 42.5 + 0.795 x 42.5 + 0.5 x 42.5) = 37.4 mm 4.
LC6D Connector Cable LC6C Power Connector Cable Model LC6-1-C1--X258 Model LC6-1-C2--X252 Electric actuator LC6D Electric actuator LC6C Cable length 1 1m 3 3m 5 5m Cable length 1 1m 2 2m 5 5m Power connector Cable length: 1 to 5m Motor cable b Cable length: 1 to 5m 13 12 11 10 6 5 4 3 2 1 a Motor cable 7 13 12 11 10 9 8 6 5 4 3 2 1 Switch cable 14 15 16 17 18 Interface cable 7 9 8 Power cable
* 1015 10 1% 2162 LCD * -8No.PS-OMV0008CN-E ISE70G 02 L2 M 3 Y K T ISE70G 0~1 MPa ISE75G 0~2 MPa ISE76G 0~5 MPa ISE77G 0~10 MPa ISE78G 0~16 MPa 2 A A B B 02 Rc1/4 N02 NPT1/4 F02 G1/4 :ISO1179-1 1 M12 5m M12 5m T S : L IO-Link/1+2 NPNorPNP L2 1 M SI2 1 2kPaMPa / A ZS-50-A M46 2 B ZS-50-B M46 2 ZS-48-A ZS-31-B 5 m M12 ZS-31-C 5 m -9No.PS-OMV0008CN-E M12 4 24 OUT1 IO-Link
x 1.5 NBR O-ring JIS B 2401 P3 JIS B 2401 P4 JIS B 2401 P5 NBR O-ring (1) (1) (1) P36203015 NBR Seal (A) P36203016 NBR Seal (B) KT-IRV1000 KT-IRV2000 KT-IRV3000 Repair kit no.
Refer to Fig.1) 3) Remove the junction box B (top) for all stations using a precision screwdriver. (Refer to Fig.2) (Remove the junction box B from D side.) 4) Remove all connectors mounted to the junction box B.