SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2KB40-10DMZ-A93"

Magnet: None, Mounting: F (Rod Flange), Bore Size: 32mm, Stroke: 10mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces), Auto Switch: No Switch, Lead Wire: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Temperature Resistant: XB6 [Heat Resistant (-10 to 150°C)]

Magnet: D (Built-in), Rod Type: Standard, Mounting: B [Through Hole (Standard)], Bore Size: 25mm, Stroke: 10mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: M9PV--Solid State , Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: Z (5m)

Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 80mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: M9PV--Solid State , Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired

Magnet: D (Built-in), Mounting: L (Foot), Type: Standard, Bore Size: 16mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: M9PV--Solid State , Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: Z (5m

Magnet: D (Built-in), Rod Type: Standard, Mounting: A (Both Ends Tapped), Bore Size: 12mm, Stroke: 10mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: M9NV--Solid State , Gen. Purpose, 3 Wire NPN, Vertical

Magnet: D (Built-in Magnet), Mounting: A (Both Ends Tapped), Bore Size: 32mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case

Magnet: D (Built-in), Rod Type: Standard, Mounting: A (Both Ends Tapped), Bore Size: 40mm, Stroke: 10mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: M9PV--Solid State , Gen. Purpose, 3 Wire PNP, Vertical

SMC has redesigned the NCQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions.  Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, double rod, compact cylinder , Bore sizes (mm):  12, 16,

Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 80mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector

Magnet: D (Built-in), Rod Type: Standard, Mounting: B [Through Hole (Standard)], Bore Size: 32mm, Stroke: 10mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Mounting: D (Double Clevis), Type: Standard, Bore Size: 32mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: V (Single Knuckle Joint)

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25

Magnet: D (Built-in Magnet), Mounting: B (Through-hole, Standard), Bore Size: 25mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the

Magnet: D (Built-in Magnet), Mounting: B (Through-hole, Standard), Bore Size: 20mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the

Magnet: D (Built-in), Mounting: B (Through Hole [Standard]), Bore Size: 20mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves)

Variation: D (2-step Control, Single Acting/Bellows Seal, O-ring Seal), Flange Size: 40, Indicator, Actuator Port Direction: w/o Indicator, Actuator Port Direction on Flange Side, Temperature Specifications, Heater: 5 to 60°C, w/o Heater, Auto Switch: A93 (A93--Reed, DC Volt, AC Volt, LED, Horizontal), Lead Wire: L (3m), Number of Switches, Mounting Position: A (2 pcs, Valve Open/Closed)

Applicable model: D-A73, A73H, A73C, A93, A93V, A53, A54, B53, B54, C73, C73C, E73A, Z73, D-R73, R73C, 97, 93A, A33, A34, A33A, A34A, A44, A44A 2) When using a 2-color indicator type auto switch (D-A79W, A59W and B59W), the auto switch will constantly remain ON if the connections are reversed. 1. Keep wiring as short as possible.

Indicator light Lead wire length (m) Applicable load 0.5 (Nil) 3 (L) 5 (Z) Auto switch model Special function Type Load voltage AC DC Wiring (Output) Electrical entry Pre-wire connector In-line Perpendicular Reed switch 3-wire (NPN equivalent) IC circuit A96 A96V 5 V Grommet Yes 2-wire 24 V A93 12 V 100 V Relay, PLC A93V 3-wire (NPN) 3-wire (PNP) M9N M9NV IC circuit 5 V, 12 V M9PV

However, please contact SMC for water-resistant products of 20 and 25. 2 1 m type lead wire is only applicable to D-A93. Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN Solid state auto switches marked with are produced upon receipt of order.

B64 M9NW Relay PLC Yes 3-wire (NPN) F59W Diagnostic indication (2-color indicator) 5 V, 12 V IC circuit M9PW 3-wire (PNP) F5PW M9BW 24 V 2-wire 12 V Grommet J59W M9NA1 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V M9PA1 Water resistant (2-color indicator) M9BA1 2-wire 12 V F5BA1 F59F 4-wire (NPN) IC circuit IC circuit IC circuit 5 V, 12 V Diagnostic output (2-color indicator) A96 A93