V V V v v IC circuit 3-wire (PNP) M9PWV M9PW V V V v v Relay, PLC Diagnostic indication (2-color indicator) Grommet Yes 24 V 2-wire 12 V M9BWV M9BW V V V v v 3-wire (NPN) 5 V, 12 V M9NAV1 M9NA1 v v V v v IC circuit 3-wire (PNP) M9PAV1 M9PA1 v v V v v Water resistant (2-color indicator) 2-wire 12 V M9BAV1 M9BA1 v v V v v 1 Water-resistant type auto switches can be mounted on the above models
V V V V 28.8 8.5 21 10 9 8.5 9 81 Vacuum port (V port) Note 4) 107 (M5 x 0.8) Note 1) The above dimensions are for ZZQ1-BSB.
24 V 100 V, 200 V DIN terminal Relay, PLC Diagnostic indication (2-color indication) B59W Grommet H7A1 H7A2 H7B H7C G39A K39A H7NW H7PW H7BW 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Grommet 2-wire 12 V Connector 3-wire (NPN) 2-wire IC circuit 5 V, 12 V Terminal conduit 12 V Relay, PLC 24 V 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Diagnostic indication (2-color indication
Symbol Size Tubing connection 001 Same diameter tubing Symbol Model Oval type Round type H Male connector v v S Hexagon socket head male connector v v F Female connector v v L Male elbow v v LU Branch male elbow v V Universal male elbow v v W Extended male elbow v v T Male branch tee v v Y Male run tee v v D Male delta union v v U Branch Y v UD Double branch Y v M5 M5 x 0.8 01 R1/8, Rc1
Operation of the cylinder with its body fixed will damage the wear ring, resulting in increase of particle generation or malfunction. 12-REA40 10-AS2001F-06-X214 10-AS2201F-02-06-X214 10-AS2301F-02-06-X214 12-REA50 10-AS3001F-08-X214 10-AS3201F-02-08-X214 10-AS3301F-02-08-X214 12-REA63 10-AS3001F-08-X214 10-AS3201F-02-08-X214 10-AS3301F-02-08-X214 Although speed adjustment is possible with
0 1 Standard Micro load Port size Nil 02 N02 With gasket Rc 1/4 NPT 1/4 16-9-3 2 Series IS3000 Construction Precautions IS3000-02/3010-02 (Rc 1/4 thread) Be sure to read before handling.
V V V V 28.8 8.5 21 10 9 8.5 9 81 Vacuum port (V port) Note 4) 107 (M5 x 0.8) Dimensions Note 1) The above dimensions are for ZZQ1-BSB.
Reed Switch: Direct Mounting Style D-A90(V)/D-A93(V)/D-A96(V) . Solid State Switch: Direct Mounting Style D-M9N(V)/D-M9P(V)/D-M9B(V) . 2-color Indication, Solid State Switch: Direct Mounting Style D-F9NW(V)/D-F9PW(V)/D-F9BW(V) . Safety Instructions . Warning . Actuator Precautions . Caution on Design . Selection . Mounting . Piping. Lubrication . Air Supply. Operating Environment.
Metric size Inch size 3.2 4 6 8 10 12 1/8" 5/32" 1/4" 5/16" 3/8" 1/2" AS1002FS V V V V V V AS2002FS V V V V AS2052FS V V V V AS3002FS V V V V V V V AS4002FS V V V V 1 Use caution at the max. operating pressure when using soft nylon or polyurethane tubing. (Refer to the Web Catalog for details.)
Metric size Inch size 3.2 4 6 8 10 12 1/8" 5/32" 1/4" 5/16" 3/8" 1/2" AS1002F V V V V V V AS2002F V V V V AS2052F V V V V AS3002F V V V V V V V AS4002F V V V V 1 Use caution at the max. operating pressure when using soft nylon or polyurethane tubing. (Refer to the Web Catalog for details.)
F9PW F9BW F9BA A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV 200 V A72H A73H F79 F7P J79 F79W F7PW J79W F7BA F79F A72 A73 A73C A79W F7NV F7PV F7BV J79C F7NWV F7BWV F7BAV Yes 100 V Relay, PLC 2-wire 12 V 24 V Connector Grommet Diagnostic indication (2-color indication) 3-wire (NPN) 5 V, 12 V IC circuit 3-wire (PNP) Grommet 12 V 2-wire Connector 3-wire (NPN) Relay, PLC Yes 24 V Diagnostic
circuit 5 V, 12 V 5 V With diagnostic output (2-color indicator) 100 V Grommet IC circuit 100 V or less B54 B64 100 V, 200 V Relay, PLC 12 V 2-wire 24 V 200 V or less C73C C80C Connector IC circuit 24 V or less B59W Grommet Diagnostic indication (2-color indicator) 1 Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance
F9PWV F9BWV A93 M9N M9P M9B F9NW F9PW F9BW F9BA 200 V A72H A73H F79 F7P J79 F79W F7PW J79W F7BA F79F A72 A73 A73C A79W F7NV F7PV F7BV J79C F7NWV F7BWV F7BAV Yes 100 V Relay, PLC 2-wire 12 V 24 V Connector Grommet Diagnostic indication (2-color indication) 3-wire (NPN) 5 V, 12 V IC circuit 3-wire (PNP) Grommet 12 V 2-wire Connector 3-wire (NPN) Relay, PLC Yes 24 V Diagnostic
A I R C U S H I O N .Both Ends N .None H .Cap End R .Rod End *Note: Non Adjustable Cushions are available on units above 4Bore Please Consult SMC Customer Service **Note: Cushions not recommended for Strokes below 3 How To Order MT4 With Non Standard XI Dimension NCA1 T X46US (XI = Total Inches) T Specify XI Dimension in inches Construction Type S T Y L E O P T I O N O V E R S I Z E D R
A I R C U S H I O N .Both Ends N .None H .Cap End R .Rod End *Note: Non Adjustable Cushions are available on units above 4Bore Please Consult P/A Customer Service **Note: Cushions not recommended for Strokes below 3 How To Order MT4 With Non Standard XI Dimension NCA1 T X46US (XI = Total Inches) T Specify XI Dimension in inches Construction Type S T Y L E O P T I O N O V E R S I Z E D R
To minimize the voltage drop, use 100/200 V AC and 24 V DC wires with the largest sectional areas possible and keep the wiring length as short as possible. 5. The 100/200 V AC wire must not be bundled with or arranged in close proximity with the input/output lines of control terminals or encoder signal lines. If possible, keep a 100 mm or larger distance from such lines. 6.
12 V Relay, PLC Grommet Yes 24 V 3-wire (NPN) 5 V, 12 V IC circuit Diagnostic indication (2-color indication) 3-wire (PNP) 2-wire 12 V Yes No Yes No 100 V Reed auto switch Relay, PLC IC circuit 100 V or less Grommet 24 V 2-wire 12 V 100 V, 200 V 200 V or less Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid
T2 V W T1 S 6.5 10 18 50 80 11 YB-03 32, 40 Part No.
OUT port size Material Symbol 01 02 Port size 1/8 (6A) 1/4 (8A) Stations D side U side 1 2 3 4 5 n Body material Brass Symbol D H Seal material FKM FKM 02 : 10 2 stations : 10 stations All IN ports are 3/8. Stainless steel Refer to the L dimensions on page 6 regarding the maximum number of stations.
Option Body material Nil N Body only With silencer 1 2 ADC12 (Aluminum) SCS14 (Stainless steel) For AIR EXH: AN200-02 Port size Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Diaphragm material 02 03 1/4 (8A) 3/8 (10A) 1 PTFE (Fluoro resin) JIS Symbol Type Thread