SMC Corporation of America
Elite Part Number Search
Search Results "ZSE20BF-L-P-01-W"

Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L2 [Out1: IO-Link, Switch Output (N/P); Out2: Switch Output (N/P)], Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: Units Selection Function, Calibration Certificate: None, Certificate in both English and Japanese, Flow Direction: R (Right to Left)

Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L2 [Out1: IO-Link, Switch Output (N/P); Out2: Switch Output (N/P)], Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only)

Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L2 [Out1: IO-Link, Switch Output (N/P); Out2: Switch Output (N/P)], Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: M (SI Unit Only)

Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L2 [Out1: IO-Link, Switch Output (N/P); Out2: Switch Output (N/P)], Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only), Calibration Certificate: A (Yes), Flow Direction: R (Right to Left)

Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L2 [Out1: IO-Link, Switch Output (N/P); Out2: Switch Output (N/P)], Lead Wire: N (w/o Lead Wire and M12 Connector)

Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L2 [Out1: IO-Link, Switch Output (N/P); Out2: Switch Output (N/P)], Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: Units Selection Function, Calibration Certificate: A (Yes)

Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L2 [Out1: IO-Link, Switch Output (N/P); Out2: Switch Output (N/P)], Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only), Calibration Certificate: A (Yes)

Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L2 [Out1: IO-Link, Switch Output (N/P); Out2: Switch Output (N/P)], Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: Units Selection Function, Calibration Certificate: A (Yes)

used STX ETX ACK NAK ASCII code 30H 31H 32H 33H 34H 35H 36H 37H 38H 39H Number used 0 1 2 3 4 5 6 7 8 9 ASCII code 2DH 20H Number used SP Space Minus ASCII code 41H 42H 43H 44H 45H 46H 47H 48H 49H 4AH Character used A B C D E F G H I J ASCII code 4BH 4CH 4DH 4EH 4FH 50H 51H 52H 53H 54H Character used K L M N O P Q R S T ASCII code 55H 56H 57H 58H 59H 5AH Character used U V W X Y Z HEF002

-3 ASCII code ASCII code 02H 03H 06H 15H Code used STX ETX ACK NAK ASCII code 30H 31H 32H 33H 34H 35H 36H 37H 38H 39H Number used 0 1 2 3 4 5 6 7 8 9 ASCII code 2DH 20H Number used SP Space Minus ASCII code 41H 42H 43H 44H 45H 46H 47H 48H 49H 4AH Character used A B C D E F G H I J ASCII code 4BH 4CH 4DH 4EH 4FH 50H 51H 52H 53H 54H Character used K L M N O P Q R S T ASCII code 55H 56H 57H

U C S O H L 1 Series IRV Dimensions IRV1000 IRV2000 53 55 41 30 50 SMC 35 P K U C SMC S O H L P K U C S O H L 40 34 8 x 6.5 15.4 x 5.4 Approx. 106 Approx. 50.6 18 Approx. 79 Atmosphere Atmosphere 45.5 13 SET VAC SET G SET G 30 SET VAC 43 Pad side Vacuum pump side Pad side Vacuum pump side Approx. 43 35 2-Rc 1/8 Connection port 2-Rc 1/8 Vacuum gauge port 2-Rc 1/4 Connection port Approx. 60

M3 Port size With One-touch fitting AS M3 x 0.5 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 M5 Thread type U10/32 01 02 03 04 ASP R Unified thread (10-32 UNF) Metric thread (M3, M5) Nil ASN N NPT AQ ASV Needle Valve/Flow Characteristics AK AS1201F-M5, AS1211F-M5 AS1301F-M5, AS1311F-M5 AS2201F-01, AS2211F-01 AS2301F-01, AS2311F-01 AS1201F-M3, AS1211F-M3 AS1301F-M3, AS1311F-M3 ASS Inlet pressure: 0.5

PNP1 A1 A M SI*2 () P (psi)*1 1 2kPaMPa A2 B () M5 M5 M5 B 01 R1/8 N01 NPT1/8 D + 1 L 2m -8No.PS-OMS0006CN-G / A ZS-46-A1 3X8L (2 ) B ZS-46-A2 3X8L (2 ) ZS-46-B + ZS-46-D ZS-46-3L 3 2m ZS-27-01 R1/8 ZS-46-N1 NPT1/8 ZS-46-N2 4mm ZS-46-C4H 6mm ZS-46-C6H 1/4 inch ZS-46-N7H 4mm ZS-46-C4L 6mm ZS-46-C6L 1/4 inch ZS-46-N7L -9No.PS-OMS0006CN-G LCD LCD 4 ON/OFF ON/OFF (kPaMPa

Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: 01 (R1/8), Lead Wire: w/o Lead Wire, Bracket: A2 [Bracket B (ZS-46-A2)]

Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: 01 (R1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B (ZS-46-A2)], Operation Manual: K (Operation Manual, Calibration Certificate)

Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: M (SI Unit Only), Piping Specification: 01 (R1/8)

Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: 01 (R1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A1 [Bracket A (ZS-46-A1)]

Rated Vacuum Range: -100.0 to 100.0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: R1/8, Lead Wire: w/o Lead Wire, Bracket: A2 [Bracket B (ZS-46-A2)], Operation Manual: -

Rated Vacuum Range: -100.0 to 100.0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: R1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: A2 [Bracket B (ZS-46-A2)], Operation Manual: Operation Manual, Calibration Certificate