SMC Corporation of America
Elite Part Number Search
Search Results "Y310-02-1-D"

(English 1 pc./Japanese 1 pc.), Operation Manual (for installation/operation) 2 pcs. (English 1 pc./Japanese 1 pc.), Y-strainer 20A 1 pc., Barrel nipple 20A 1 pc., Drain pan for the pump 1 pc.

(English 1 pc./Japanese 1 pc.), Operation Manual (for installation/operation) 2 pcs. (English 1 pc./Japanese 1 pc.), Y-strainer (40 meshes) 25A, Barrel nipple 25A, Anchor bolt fixing brackets 2 pcs.

How to Calculate the Flow Rate For obtaining the flow rate, refer to page 4-1-6. 4-16-1 2 Series VS3115/3110 How to Order VS311 D L 5 01 5 Thread type Accessory (Option) Nil Rc Mounting With indicator light L P With manual override N NPT T NPTF E Nil Without bracket Port size Piping Electrical entry B With bracket G 1 8 Rc 1 4 Rc 1 4 Rc 3 8 Without sub-plate Rc 01 02 02 03 00 Body ported

Aereo 081045 Santa Fe de Bogot, Colombia TEL: 1-424-9240 FAX: 1-424-9260 16-14-20 SMCs Global Service Network Europe Oceania/Asia AUSTRALIA SMC Pneumatics (Australia) Pty.Ltd. 14-18 Hudson Avenue Castle Hill NSW 2154, Australia TEL: 02-9354-8222 FAX: 02-9894-5719 FINLAND SMC Pneumatics Finland OY PL72, Tiistinniityntie 4, SF-02231 ESP00, Finland TEL: 09-8595-80 FAX: 09-8595-8595 NORWAY SMC

Contents Bracket 1 pc. M6 x 10l (Hex. bolt) 2 pcs. BM58 Bracket set Ball valve/Rc 1/2 1 pc. Barrel nipple/R 1/2 2 pcs. Elbow/Rc 1/2 1 pc. Ball valve piping set ADH-C400 Note) The accessories (Option) are shipped unassembled, but packed in the same container.

ALF400 ALT-9 1.17-11 Auto Feed Lube ALF400 to 900 Operating pressure range Tank and line pressure How to Order Auto Feed Lube ALF 40 02 0 Option Auto Feed Lube Port size Symbol Description Applicable model W/ bracket ALF400 to 600 B 02 03 04 06 10 12 14 20 4 1 Body size 8 3 AC 40 50 60 80 90 2 1 2 1 4 3 4 3 AV 1 1 2 1 1 1 2 2 1 4 1 AU 2 1 AF Thread Rc (PT) NPT G (PF) N F AR Note 1) Tank

VNA VNA 2 1 2 1 2 1 VNA VNA D-X Technical Data 1177

HRX-OM-R028 Contents Contents Chapter 1 Read before using. 1-1 1.1 Communication mode and operation method .1-2 1.2 Communication port.1-3 1.3 Key operations.1-4 1.4 Parameters .1-6 Chapter 2 Contact input/output communication . 2-1 2.1 Precautions for communication .2-1 2.1.1 Precautions wiring communication. 2-1 2.1.2 Precautions after wiring and before communication . 2-1 2.2 Communication

HRX-OM-S010 Chapter 1 Read before using Contents Chapter 1 Read before using . 1-4 1.1 Communication mode and operation method . 1-5 1.2 Communication port . 1-6 1.3 Key operations . 1-7 1.4 Parameters . 1-9 Chapter 2 Contact input/output communication . 2-1 2.1 Precautions for communication . 2-1 2.1.1 Precautions wiring communication . 2-1 2.1.2 Precautions after wiring and before communication

HRX-OM-Q033 Contents Contents Chapter 1 Read before using . 1-1 1.1 Communication mode and operation method . 1-2 1.2 Communication port . 1-3 1.3 Key operations . 1-4 1.4 Parameters . 1-6 Chapter 2 Contact input/output communication . 2-1 2.1 Precautions for communication . 2-1 2.1.1 Precautions wiring communication . 2-1 2.1.2 Precautions after wiring and before communication . 2-1 2.2

HRX-OM-M091 Contents Contents Chapter 1 Read before using . 1-1 1.1 Communication mode and operation method . 1-2 1.2 Communication port . 1-3 1.3 Key operations . 1-4 1.4 Parameters . 1-6 Chapter 2 Contact input/output communication . 2-1 2.1 Precautions for communication . 2-1 2.1.1 Precautions wiring communication . 2-1 2.1.2 Precautions after wiring and before communication . 2-2 2.2

HRX-OM-T004 Contents Contents Chapter 1 Read before using . 1-1 1.1 Communication mode and operation method . 1-2 1.2 Communication port . 1-3 1.3 Key operations . 1-4 1.4 Parameters . 1-6 Chapter 2 Contact input/output communication . 2-1 2.1 Precautions for communication . 2-1 2.1.1 Precautions wiring communication . 2-1 2.1.2 Precautions after wiring and before communication . 2-1 2.2

Maintenance detection signal ON OFF Output Requirement for maintenance detected ON OFF Input External switch signal 1, 2 455 IZN10 Series Dimensions 06 07 06 07 Energy saving static neutralization nozzle/IZN10-01 High flow rate nozzle/IZN10-02 20 Note 1) (110) 16 100 5 5 46 A 3.4 18.5 11 6 5 6 A 8 7 (Tap for ground wiring) M3 x 0.5 depth 4 40 25 12 A 93.6 A-A (mm) A Model 01 02 01 02 IZN1006

Aereo 081045 Santa Fe de Bogot, Colombia TEL: 1-424-9240 FAX: 1-424-9260 15-18-20 SMCs Global Service Network Europe Oceania/Asia AUSTRALIA SMC Pneumatics (Australia) Pty.Ltd. 14-18 Hudson Avenue Castle Hill NSW 2154, Australia TEL: 02-9354-8222 FAX: 02-9894-5719 FINLAND SMC Pneumatics Finland OY PL72, Tiistinniityntie 4, SF-02231 ESP00, Finland TEL: 09-8595-80 FAX: 09-8595-8595 NORWAY SMC

Suction Verification High Vacuum Set-value correction by auto-shift function Suction Work 1 Work 2 Work n Supply pressure normal Supply pressure drop Supply pressure increase Max. A Rectified value P-1 Rectified value P-1 (Differential) Pressure H-1 (P-3) H-1 (H-2) n-1 Min.

Aereo 081045 Santa Fe de Bogot, Colombia TEL: 1-424-9240 FAX: 1-424-9260 15-18-20 SMCs Global Service Network Europe Oceania/Asia AUSTRALIA SMC Pneumatics (Australia) Pty.Ltd. 14-18 Hudson Avenue Castle Hill NSW 2154, Australia TEL: 02-9354-8222 FAX: 02-9894-5719 FINLAND SMC Pneumatics Finland OY PL72, Tiistinniityntie 4, SF-02231 ESP00, Finland TEL: 09-8595-80 FAX: 09-8595-8595 NORWAY SMC

How to Order 1 2 PAX1 1 02 Option Body material Nil N Body only With silencer 1 2 ADC12 (Aluminum) SCS14 (Stainless steel) For AIR EXH: AN200-02 Port size Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Diaphragm material 02 03 1/4 (8A) 3/8 (10A) 1 PTFE (Fluoro

132.5 FLUID I N 125.5 103.5 P2 58.5 48.5 202 114 3.5 3 AIR SUP(P2) FLUID IN Rc 1/2, 3/4 Rc1/4 17-5-157 Process Pump Automatically Operated Type, Built-in Pulsation Attenuator (Internal Switching Type) Series PAX1000 How to Order 1 2 PAX1 1 02 Option Body material Nil N Body only With silencer 1 2 ADC12 (Aluminum) SCS14 (Stainless steel) For AIR EXH: AN200-02 Port size Diaphragm material

Example) AR30-03BG-NR-B-X425 Symbol Description Nq Body size 25 30 40 50 60 Symbol Description Nq Body size 20 25 30 40 50 60 Nw Pipe thread type Nil Rc N NPT F G + Nw Pipe thread type Nil Rc N NPT F G + 02 1/4 03 3/8 04 1/2 06 3/4 10 1 + Ne Port size 01 1/8 02 1/4 03 3/8 04 1/2 06 3/4 10 1 + Ne Port size Nil Without mounting option B*2 With bracket a Mounting Option *1 H With set nut (for