Base Mounted Wiring: 01T (Plug-in w/Terminal Block, Individual Junction Cover), Stations: 5 Stations, Passage: 2 [P(SUP): Common, E(EXH): Common, Port A,B(CYL): Bottom], Port Size: 01 (1/8), Thread: T (NPTF)
Base Mounted Wiring: 01T (Plug-in w/Terminal Block, Individual Junction Cover), Stations: 2 Stations, Passage: 1 [P(SUP): Common, E(EXH): Common, Port A,B(CYL): Side], Port Size: 01 (1/8), Thread: T (NPTF)
Base Mounted Wiring: 01T (Plug-in w/Terminal Block, Individual Junction Cover), Stations: 7 Stations, Passage: 1 [P(SUP): Common, E(EXH): Common, Port A,B(CYL): Side], Port Size: 01 (1/8), Thread: T (NPTF)
Base Mounted Wiring: 01T (Plug-in w/Terminal Block, Individual Junction Cover), Stations: 4 Stations, Passage: 1 [P(SUP): Common, E(EXH): Common, Port A,B(CYL): Side], Port Size: 01 (1/8), Thread: T (NPTF)
Base Mounted Wiring: 01T (Plug-in w/Terminal Block, Individual Junction Cover), Stations: 6 Stations, Passage: 1 [P(SUP): Common, E(EXH): Common, Port A,B(CYL): Side], Port Size: 01 (1/8), Thread: T (NPTF)
Base Mounted Wiring: 01T (Plug-in w/Terminal Block, Individual Junction Cover), Stations: 3 Stations, Passage: 1 [P(SUP): Common, E(EXH): Common, Port A,B(CYL): Side], Port Size: 01 (1/8), Thread: T (NPTF)
Base Mounted Wiring: Plug-in w/Terminal Block, Individual Junction Cover, Stations: 5 Stations, Passage: 2 [P(SUP): Common, E(EXH): Common, Port A,B(CYL): Bottom], Port Size: 1/8, Thread: NPTF, Control Unit: -, Voltage Air Release Valve: -
Base Mounted Wiring: Plug-in w/Terminal Block, Individual Junction Cover, Stations: 2 Stations, Passage: 1 [P(SUP): Common, E(EXH): Common, Port A,B(CYL): Side], Port Size: 1/8, Thread: NPTF, Control Unit: -, Voltage Air Release Valve: -
Base Mounted Wiring: Plug-in w/Terminal Block, Individual Junction Cover, Stations: 7 Stations, Passage: 1 [P(SUP): Common, E(EXH): Common, Port A,B(CYL): Side], Port Size: 1/8, Thread: NPTF, Control Unit: -, Voltage Air Release Valve: -
Base Mounted Wiring: Plug-in w/Terminal Block, Individual Junction Cover, Stations: 4 Stations, Passage: 1 [P(SUP): Common, E(EXH): Common, Port A,B(CYL): Side], Port Size: 1/8, Thread: NPTF, Control Unit: -, Voltage Air Release Valve: -
Base Mounted Wiring: Plug-in w/Terminal Block, Individual Junction Cover, Stations: 6 Stations, Passage: 1 [P(SUP): Common, E(EXH): Common, Port A,B(CYL): Side], Port Size: 1/8, Thread: NPTF, Control Unit: -, Voltage Air Release Valve: -
Base Mounted Wiring: Plug-in w/Terminal Block, Individual Junction Cover, Stations: 3 Stations, Passage: 1 [P(SUP): Common, E(EXH): Common, Port A,B(CYL): Side], Port Size: 1/8, Thread: NPTF, Control Unit: -, Voltage Air Release Valve: -
Base Mounted Wiring: 01T (Plug-in w/Terminal Block), Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 5 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 01 (1/8), Thread: T (NPTF)
Base Mounted Wiring: Plug-in w/Terminal Block, Individual Junction Cover, Stations: 5 Stations, Passage: 1 [P(SUP): Common, E(EXH): Common, Port A,B(CYL): Side], Port Size: NPT1/8
Base Mounted Wiring: Plug-in w/Terminal Block, Stations: 5 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: NPTF1/8, Control Unit: -
If the alarm is still generated when the power is reapplied, please contact SMC. (2) Please check if the power supply capacity is insufficient or not. 55 -
. / See Operating procedure input / output signals Alarm for Step data ALM2/code: short an interval between the 1-051 is generated. input signal of IN* and the for each operation type on P .27 Drive or inputting the signals at
/code1-051 15ms IN* 30ms DRIVE /P25 1) No. RESET 15ms 3 30ms /P25 1) No. No. 4 PLC No. 15ms 1IN* 30ms DRIVE /P25 1) / No. OUT 15ms 2 30msmsec /P25 1) No. OUT -42- No. No. PLC /P25 1) No. OUT 3 INP INP LEFS 0.5 LEFB 1 4 1INP BUSYOFF 5 6 7 () 1 / EMG SVREOFF 2 /CN1 BK RLS DC24V(+) /P34 5.6 8 1 , , EMG SYREOFF /P911 2.1.
E 60 -