SMC Corporation of America
Elite Part Number Search
Search Results "VV5FR2-01SU-121-C6"

Bucharest, Romania SLOVAKIA (421) 41 321321 1 Fantransk 1223, 01301 Teplika nad Vhom, Slovakia SLOVENIA (386) 7388 5412 Mirnska cesta 7, SLO-8210 Trebnje, Slovenia SPAIN (34) 945 184 100 Zuazobidea 14, 01015 Vitoria, Spain SWEDEN (46) 8 603 12 00 Ekhagsvgen 2931, SE-141 71 Segeltorp, Sweden SWITZERLAND (41) 052 396 31 31 Dorfstrasse 7, CH-8484, Weisslingen, Switzerland UNITED KINGDOM (44) 0845 121

0.001 MPa 1 kPa 0.01 kPa DC1224 V10P-P10 50 mA() PSE30DC15 V(1 M) PSE31DC420mA100 ) 1 26.4V NPNPNP 2 80 mA DC30 V(NPN) 1 V(80 mA) 1ms 20 ms160 ms640 ms1280 ms 0.1F.S. 2 15 V()1 k 0.2F.S.()150 ms 0.6F.S. 1.0F.S. 1.5F.S. 420 mA() 300 (DC12 V)600 (DC24 V) 50 0.2F.S.() 150 ms 2 1.0F.S. 1.5F.S. 2.0F.S. 0.5F.S. 2 digits 0.5F.S.1 digit 31/2 72(/) OUT1ON()OUT2ON() 2 ()Low5 msLow0.4 V 121

A6063) Valve (Material: SUS304) 6 Valve seal 2 (Maintenance part) 3 (Valve seal 2) Nut assembly (Maintenance part) (Set of a nut and a washer) 9 Washer (Material: SUS304 or equivalent) Nut (Material: SUS304 or equivalent) (Shaft) 11 XL-OMS0001-B 5-2.Dimensions C E C E E (KF flange) Fd (K flange) Fn D H B A G A Unit: mm Model A B C D E Fn Fd G H XLA-16-2 40 108 38 20 30 17 44 XLA-25-2 50 121

-3 XL1A25-60S-2 1 2 H5 AC100V 600/130 800/180 / AC200V 2400/130 3200/180 1[W] 216 PTC 200V PTC 200 150 100V PTC 0 5 10 15 20 25 30 ( 30 10 XL-OMY0001 5 5-1 1 , SUS304 8 4 SUS304 10 , SUS316L 7 5 A6063 2 1 6 SUS304 3 2 9 2 SUS304 SUS304 11 XL-OMY0001 5-2 C E E E KF K Fd Fn C D H B A G A mm A B C D E Fn Fd G H XLA-16-2 40 108 38 20 30 17 44 XLA-25-2 50 121

Valve (Material: SUS304) 6 3 Valve seal 2 (Maintenance part) Nut assembly (Maintenance part) (Set of a nut and a washer) 9 (Valve seal 2) Washer (Material: SUS304 or equivalent) Nut (Material: SUS304 or equivalent) (Shaft) 11 XL-OMV0007 5-2.Dimensions Size 16, 25, 40 E C E (KF flange) Fn C E D J H B A G A Unit: (mm) Model A B C D E Fn Fd G H J XLC-16-2 40 108 38 20 30 17 44 19 XLC-25-2 50 121

Material: SUS304) 6 3 Valve seal 2 (Maintenance part) Nut assembly (Maintenance part) (Set of a nut and a washer) 9 (Valve seal 2) Washer (Material: SUS304 or equivalent) Nut (Material: SUS304 or equivalent) Shaft (Material: SUS304) 7 11 XL-OMV0017 5-2.Dimensions C E C E E (KF flange) (K flange) Fd Fn D H B A G A Unit: mm Model A B C D E Fn Fd G H XLF-16-2 40 108 38 20 30 17 44 XLF-25-2 50 121

XYC Exterior dimensions D G C C B J Fd (K Flange) 45 H Fn (KF Flange) A E Unit:mm Model A B C D E Fn Fd G H J XYC-25 100.2 85 48 1 23.5 40 26 64 28 XYC-40 130 115 66 2 38 55 41 84 36 C D G C B J Fd (K Flange) 45 K H Fn (KF Flange) A E Unit:mm Model A B C D E Fn Fd G H J K XYC-50 178 121 80 31 53 75 52 104 29 10.5 XYC-63 209 148 100 39 61 87 95 70 126 36 9 XYC-80 268 177 117 45.5 80 114 110

6x6.6 XMD-50 70 183 79 2 75 52 68 20 17.5 XMD-63 88 217 100 3 87 95 114 70 72 20 19.5 P.C.D 92.1 8x 8.4 XMD-80 90 256 117 3 114 110 83 98 20 26.5 D G C C K J H B Fd (K Flange) 45 Fn (KF Flange) A E Unit: mm Model A B C D E Fn Fd G H J K XYD-25 100.2 86.7 48 1 23.5 40 26 66 16 7.5 XYD-40 130 114 66 2 38 55 41 84 20 15 XYD-50 178 128 79 2 53 75 52 95 20 17.5 XYD-63 209 163 100 3 61 87 95 70 121

or 1/4" 1.6* 1.6* 6 mm or 1/4" 1.0* 1.0* 9 0.6 37 1/4 6 mm or 1/4" 2.0 2.0 11 1.1 67 3/8 10 mm or 3/8" [6 mm or 1/4" (x)] 4.1 4.1 13 2.3 140 3/8 10 mm or 3/8" 17 4.3 262 1/2 10 mm or 3/8" 3.6 3.6 20 5.4 330 1/2 10 mm or 3/8" 5.0 5.0 25 10.5 610 1/2 10 mm or 3/8" 9.5 9.5 32 21 1282 3/4 10 mm or 3/8" 18.0 18.0 40 43 2624 3/4 10 mm or 3/8" 35.0 35.0 50 84 5126 1 10 mm or 3/8" 67.0 67.0 60 121

Err42 Err8 No.1ON ON ON LEDNo.10 Err9 3 P3 2 P2 Err9 Err9 ON ON ON ()5mm Err5 5mm 1 1 Err10 Err11 CPU Err12 ON 8P8 48 11-2 () 200 200 6P6 *L=1mm *200.0 1 PRG STEP P6 200 200 300mm/sec 50% 35% 49 12. 121 No. P1 No.

2 5 1 19 2 4 1 18 O 4 3 1 17 O 4 2 1 16 4 1 1 15 2 13 3. 3. 3. 3. 3-1. ,,,2 2 3-2. 2 2 2 32 40 VF3000 VZ3000 AS2000 6/4 14 4. 4. 4. 4. 4-1. , ,, ,4.1 , ,4.1 ,,, 4.1 4.1 [N] 5 10 15 20 25 30 40 50 75 100 32 14 13 13 13 13 13 12 11 10 9 40 23 22 22 21 21 21 19 18 16 15 , , , 4.24.34.2, 15 4.2 4.2 [N] [MPa] [mm 2] 0.15 0.2 0.3 0.4 0.5 0.6 0.7 [mm] OUT 804 121

ON/OFF / / 2 2 3 3 1 2 / 11 - 5.3 [] (LEC ) (LEC ) / P.42 7.3 <> (NPNPNP) LEHZ10K2-4 NPN <> INP(IN ) INP ON ON INP ON OFF ) P.50,P.52 8.3 12 - <> No.0 a b c d e f g h i j k a ABSINC ABS() / / INC()// b c ) / P.50 8.3 d e f 0(0 ) g h i )150%/ P.52 8.3 j 12 AREA ON 121 INC ABS() )No.0 120 222 AREA 13 - k INP(IN )ON INP INP ON )0.50 )No.0 22 10 12 INP 14 -

ALARMOFF 3 OFF LED a I/O STOP OFF * ALARM 10 8.6 1 2 3 PLC 15ms 30ms I/O3ms IN0 IN1 ON3IN0 IN1 IN0 ON IN0 OFF ON IN1 OFF INO IN0 44 No.JXC-OMU0004-A 8.7 LED 7 LED ALM LED ALM LED b PWR LED a 7 LED () / *1 F *4 F *4 1 9 A E 1 9 A E AE / *2 L *3 / *1 ON 8.5 ON *2 OFF LED *3 ON/OFF ,, 3 L L *4 RESET STOP ON M24V7 LEF a b 45 No.JXC-OMU0004-A 9. () 9.1 .121

SERVO MOTOR 121 to 126 12.1 Servo motor with a lock . 122 19 12.1.1 Features 122 12.1.2 Characteristics of servo motor with a lock 124 12.2 Protection from oil and water . 125 12.3 Cable . 125 12.4 Rated speed of servo motor. 125 12.5 Mounting connectors . 126 13.

The resistor requirements are: 121 1% metal film 1/4 W Terminating resistors should not be installed at the end of a drop line, only at the two ends of trunk line. -13No.EX-OME0003-H Power supply wiring Connect a power supply cable connector to the power supply connector on the SI unit.

length 1200/900/400/160/100 m Communication supply voltage 15 to 30 VDC Solenoid valve supply voltage 24 VDC +10%/-5% Output channels 16 outputs Output type Sink/NPN (positive common) Connected load Solenoid valve with surge voltage suppressor of 24 VDC and 2.1 W or less (manufactured by SMC) Output when communication error occurs Clear Internal current consumption (Unit) 0.1 A or less EX120/121

IDU Series 12-1 Safety instructions 121 IDX-OM-W013 Air Dryer 13 Specification for Option T 13 Specification for Option T 13-1 Safety instructions When handling the product, take care to the following precautions. Warning Only qualified persons are allowed to wire the product. Before wiring, be sure to shut off the power supply. Never perform wiring work while the product is energized.

Index Subindex Access 1 Parameter name Format Length Initial value DS Selection range (decimal number) Value/Range 0: default BDC = BDC1 1: BDC1 2: BDC2 3: BDC3 4: BDC4 5: Measuring 0x3A (58) 0 R/W Teach-in channel Int 8 bit 0 Y range 0x3B (59) 0 R Teach-in status Record 1 Byte N (64) 0 R/W Device/function name String 16 Byte *** N 0x0040 0: Deactivated 37: QA-I (Analogue current) 0x0079 (121

Terminating resistor is 121 1%, 1/4 W (Refer to Fig. 2). Refer to Fig. 3 about how to connect to the unit. Tighten the connector fixing screws (M2.5 slotted head screws) firmly with a tightening torque of 0.2 to 0.3 Nm. -16No.EX-OMI0003-H 2. Power supply wiring Connect power supply wiring to the two power supply 2-pin connectors.

: SUS304 or equivalent) Nut (Material: SUS304 or equivalent) (Shaft) Working principle Port 1(P) is normally pressurized, and the valve opens when the solenoid valve is turned ON and closes when it is turned OFF. 10 XL-OMV0016 5-2.Dimensions C (KF flange) (K flange) Fd Fn C J Port 1(P) S K L M N B T Port 3(R) A G A Unit: mm Model A B C Fn Fd G J XLAV-16-2 40 108 38 30 17 41 XLAV-25-2 50 121