Safety Instructions Warning Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
(The data can be rewritten for up to one million times, and stored for up to 20 years.) Mounting Warning 1. Do not drop or bump. Do not drop, bump, or apply excessive impacts (490 m/s2) while handling. Although the external body of a switch (switch case) may not be damaged, the switch inside could be damaged and cause a malfunction. 2.
Do not bend or pull cables repeatedly, and do not place heavy objects on them or allow them to be pinched.
Electric Actuator with Integrated Guide Series LTF Series LTF Lead screw lead mm Page Series Guide type Motor type Model Mounting orientation Ground ball screw Rolled ball screw 6 10 20 10 20 6 10 20 10 20 LTF6 LTF8 LTF6 LTF8 Page 60 to Horizontal 10 10 Page 68 to Standard Frame-type LTF motor linear guide 6 6 Page 76 to Vertical 10 10 Page 84 to Construction Page 92 Mounting Page 93
Do not use a cable longer than 20 m. Wire the DC(-) line (blue) as close as possible to the power supply. When the analogue output is used, install a noise filter (line noise filter, ferrite element, etc.) between the switch-mode power supply and this product. -7No.PF-OMW0010-D Environment Do not use the product in an environment that is constantly exposed to the splash of water.
Do not allow the table to hit the workpiece in the positioning operation and positioning area. 9. Do not apply external force to dust seal band, particularly during the actuators movement. -20- 10. When mounting the actuator, use screws with adequate length and tighten them with adequate torque.
Precautions Warning Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Precautions Warning Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate or set with wet hands. This may lead to an electric shock. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result.
Do not use the product in an environment subject to a temperature cycle. It will cause failure of the controller or its peripheral devices. 14. Do not use in a place where surges are generated.
Do not bring the product lying sideways. If you lay it sideways, it will be broken. Do not hang up the product. Do not transport the product with any part such as an air filter mounted on the fittings at the air inlet or outlet port of the product.
Conductor size (mm2) Overall diameter (mm) Colour of cover SMC product No. (1 pc.) 0.8 to 1.0 Red ZS-28-C 26-24 0.14-0.2 1.0 to 1.2 Yellow ZS-28-C-1 (28) (0.08) 1.2 to 1.6 Orange ZS-28-C-2 1.0 to 1.2 Green ZS-28-C-3 22-20 0.3-0.5 1.2 to 1.6 Blue ZS-28-C-4 1.6 to 2.0 Gray ZS-28-C-5 Do not cut the insulator.
4 to 20 Scale upper limit -32766 to 32767 10 5 5 20 20 Scale lower limit -32767 to 32766 0 1 0 0 4 If the data format is scaled data format, set the Fault Value as follows, regardless of the range setting.
Parameter Definition Item Content Default setting 0: -10..10 V 1: -5..5 V 2: -20..20 mA 3: 0..10 V 5 Analog Range Set the analog input range per channel. Selects the analog input range. 0..10 V 4: 0..5 V 5: 1..5 V 6: 0..20 mA 7: 4..20 mA 0: None None 6 Analog Filter Sets analog input filtering time per channel.
Enable Generates an error. 1 Disable Does not generate an error. -10..10 V -5..5 V -20..20 mA 0..10 V 0..5 V 1..5 V 0..20 mA Sets the analogue input device range per channel. Analogue input range (Range) Selects the analogue input range. -10..10 V 2 4..20 mA Offset binary Offset binary. Sets analogue data type which is output to PLC per unit.
Do not use this product outside of the specifications.
Do not use the product in an area where dust, powder 2. Do not operate the product beyond the specifications. dust, water, chemicals or oil is in the air. It will cause failure or malfunction. Otherwise, a fire, malfunction or actuator damage can result. Please check the specifications before use. 11. Do not use the product in an area where a magnetic 3.
Do not apply an excessive force to loosen the cushion needle.
117.5 11 11 20 50 98 70 316 3.3 280 46 20 196 44.5 84 13 6.4 117.5 11 20 11 50 70 98 319 3.3 Note 1) For AC20 only, the position of the pressure gauge is above the center of Optional specification Note 2) the piping.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 4 Electric Actuator with Integrated Guide Series LTF Lead screw lead mm Mounting orientation Motor type Series Page Model Guide type Ground ball screw Rolled ball screw 6 10 20 10 20 10 20 10 20 6 10 20 10 20 10 20 10 20 LTF6 LTF8 LTF6 LTF8 LTF6 LTF8