SMC Corporation of America
Elite Part Number Search
Search Results "SYJ3120-3L-M3-F"

g Vertical mounting Mounting orientation Horizontal mounting Ceiling mounting Wall mounting Vertical mounting m1 m2 m3 m4 Note) M3 Static load (m) M1 M1 m1 x g x X m2 x g x X m4 x g x Z Static moment z y Y M2 m1 x g x Y m2 x g x Y m3 x g x Z Z M3 m3 x g x X m4 x g x Y m4 x g Note) m4 is a weight movable by thrust.

X m3 x g m2 x g Vertical mounting Mounting orientation Horizontal mounting Ceiling mounting Wall mounting Vertical mounting M3 Static load (m) m1 m2 m3 m4 Note) M1 Static moment M1 m1 x g x X m2 x g x X m4 x g x Z z y M2 m1 x g x Y m2 x g x Y m3 x g x Z Y Z M3 m3 x g x X m4 x g x Y m4 x g Note) m4 is a mass movable by thrust.

(Example) For M3: L1 = 6 mm Applicable shaft type: W CRB2 CRBU2 Q1 = M L1 + (3 x P) (mm) CRB1 Y Q2 Size (mm) Y = L1 = 15 X Q1 M3 Size 1.5 to 9 MSU 15 20 M3, M4 1.5 to 18 M3 1.5 to 10 L2 + (3 x P) L2 = 20 30 M3, M4, M5 1.5 to 20 M3, M4 X = 2 to 13 CRJ 30 40 Q2 = M M3, M4, M5 2 to 22 M3, M4, M5 4.5 to 15 CRA1 Symbol: A3 The long shaft can be further shortened by machining male threads into

The intersection C is the conversion value 1.4 F (17C) under atmospheric pressure dew point. (per 1 m3 ) The amount of moisture at the intersection C the amount of moisture at the intersection H = the amount of condensed water 18.2 3.0 15.2 g/m3 11 Series IDF100FS/125FS/150FS Specific Product Precautions 1 Be sure to read before handling.

L M2 = F x L M3 = F x L Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Note) Displacement of Section A when force acts on Section F CYP15 (M1) CYP15 (M2) CYP15 (M3) 0.05 0.05 0.05 0.04 0.04 0.04 Deflection (mm) Deflection (mm) Deflection (mm) 0.03 0.03 0.03 0.02

4/5 Port Air Operated Valve Series SYJA3000 Model Pilot port size Valve model Configuration Port size Effective area (mm2 ) (Cv) Weight (2) (g) 22 2 position single SYJA3120-M3 Body ported 5 port base mounted (With sub-plate) 25 2 position double SYJA3220-M3 0.9 (0.05) 3 position closed center SYJA3320-M3 M3 X 0.5 M3 X 0.5 3 position exhaust center SYJA3420-M3 28 3 position pressure center

(Fixed SI unit [l/min, or l, m3 or m3 x 103] will be set for switch types without unit switching function.) Refer to the specifications of display unit for the flow rate value per pulse.

mounting attachment) M3 x 0.5 (Finger closing port) Auto switch mounting groove (2 positions) Adjustment needle for finger speed 11.6 3 9.4 S 4 6 0 0.05 4 7 7 Note) For single acting, one port is used as a breather port. 2.3 17.5 M3 x 0.5 (Finger opening port) MHKL2-12: Long stroke type 9 2-M3 x 0.5 thread depth 5 (Mounting thread) 20 3H9 depth 3 +0.025 0 13H9 depth 1.5 +0.043 0 2-M3 x 0.5

17.5 M3 x 0.5 (Finger opening port) MHKL2-12: Long stroke type 9 2-M3 x 0.5 thread depth 5 (Mounting thread) 20 3H9 depth 3 +0.025 0 13H9 depth 1.5 +0.043 0 2-M3 x 0.5 thread depth 6 (Mounting thread) 4-M4 x 0.7 thread depth 8 (Mounting thread) Bottom hole 3.4 through (Mounting hole) 0 0.1 5 Open 20 +1.2 0 4 8 10 0.02 41.6 30 20 3 22 43 0 0.2 Closed 9 26 3H9 depth 3 +0.025 0 15 36 13 57

1 Stroke (mm) 100 50 0.05 0.1 0.5 1 2 3 0.1 0.05 0.5 1 2 5 Load (kN) Load (kN) 123 Hydraulic Cylinders: Technical Data 2 Series CHA Stroke range limit charts: Bore sizes 40, 50, 63, 80 Symbol Mounting orientation Mounting orientation Mounting orientation Mounting orientation Symbol Symbol Symbol F F F F F F F F F F F F Bore size 40 Bore size 50 3000 2 4 8 9 3 7 2 4 3 7 5 2000 8 9 1 5 1 6

List part numbers of the installed valve and option in required station location separately under manifold part number. 2.1-10 Series SY100 Common SUP/Common EXH 30 Type How to Order Applicable solenoid valve (1) SS3Y1 30 05 F SY113-l-M3 SY113A-l-M3 Stations 02 Applicable blank plate assembly 2 stations ... ...

Keep the air flow within the rated flow to prevent an outflow of lubricant to the outlet side. 4 When the compressor oil mist discharge concentration is 30 mg/m3 (ANR). 5 Bowl seal and other O-rings are slightly lubricated. 28 A AC20C-B to AC40C-B Series Dimensions AC20C-B AC25C-B to AC40C-06-B (Pressure gauge port size) S N A F P2 N A F S P2 M J (Pressure gauge port size) J M R R V Q1 Q1

Displacement of Section A when force acts on Section F Displacement of Section A when force acts on Section F F A F Guide central axis (1 axis type) F For the double axis type, this is the cylinders central axis.

IDFB4E to 15E AT 1.6 [40] IDF IDU Air Flow Capacity 2.36 [60] Model IDFB3E IDFB4E IDFB6E IDFB8E IDFB11E IDFA D Circuit breaker 5 SCFM (8 m3/h) 13 SCFM (23 m3/h) 17 SCFM (29 m3/h) 19 SCFM (32 m3/h) 23 SCFM (39 m3/h) Air flow capacity (ANR) IDFB IDFB A Conditions: Inlet air pressure: 100 psi (0.7 MPa), Inlet air temperature: 100F (37.8C), Outlet air temperature: 50F (10C), Ambient temperature

Function: Normally Closed, Piping: Body Ported, Body Option: Standard, Voltage: 110VAC 50/60HZ, Lead Wire: L Plug Connector w/Lead Wire 0.3m, Surge Suppressor: None, Manual Override: Non-locking Push Style, Port Size: Base Mounted w/Sub-plate/Body Ported Mfld M3X0.5, Option: -

Function: Normally Closed, Piping: Base Mounted, Body Option: Standard, Voltage: 110VAC 50/60HZ, Lead Wire: L Plug Connector w/Lead Wire 0.3m, Surge Suppressor: None, Manual Override: Non-locking Push Style, Port Size: Base Mounted w/Sub-plate/Body Ported Mfld M3X0.5, Option: -