SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ3-31-19-M3"

Fittings & Tubing Air Cylinders Rotary Actuators 3 x M3 x 0.5 thread depth 6 25 M3 x 0.5 Finger closing port P.C.D.24 25 (Mounting thread) M3 x 0.5 Finger opening port 44 31 0 9h9-0.036 21.5 1 5 16 19 (36.5) 33.5 6.1 M3 x 0.5 thread depth 4 Vacuum suction port 2 4 4 12 2 3e8-0.028 -0.014 Open: 11, Closed: 8 8-0.05 0 3 x M3 x 0.5 thread depth 6 (Thread for mounting attachment) With Auto Switch

8 14 1/4 3/8 3/8 1/2 1/2 Refer to p.3.4-18 for further information on rod end nuts and accessories. 58 13 17 up to 600 20 17 52 12 11 27 47.3 61 M8 X 1.25 M18 X 1.5 159 40 90 17 11 30 25 70 7 19 0 32 35 18 58 17 up to 600 20 17 64 10 11 27 54.8 M18 X 1.5 170 40 15.5 68.5 M10 X 1.25 98 17 14 31 25 7 19 0 85 32 35 18 71 21 up to 750 21 25 78 14 13 32 65.8 M22 X 1.5 204 102 52 116 18.5 80.5

Model A B Same side Different sides 4 6.5 8 8 Different sides Same side D-C7, D-C8 31.5 29.5 31 31 n-2 2 15 + 45 ( ) (n = 2, 4, 6...) Approx. Hs D-C7, D-C8 30.5 35 40.5 40.5 50 + 45 (n-2) 15 50 A B 4 6.5 8 8 n-2 2 15 + 50 ( ) (n = 2, 4, 6...) D-C73C 31.5 29.5 31 31 D-C73C 15 65 65 + 50 (n-2) Approx. Hs 33 37.5 43 43 n-2 2 D-H7, D-H7W D-H7F 15 + 45 ( ) (n = 2, 4, 6...)

M3 x 0.5 8.5 Model Vacuum inlet direction q Pad dia.

Note 19 Orange Black 20 Red White Hirose Electric Co., Ltd. Fujitsu Limited Japan Aviation Electronics Industry, Ltd. J.S.T.

Note 19 Orange Black 20 Red White Hirose Electric Co., Ltd. Fujitsu Limited Japan Aviation Electronics Industry, Ltd. J.S.T.

MSUA-OM02-B PRODUCT NAME Rotary Table: High Precision Type MODEL / Series / Product Number MSUA1,3,7,20 Contents 2 Safety Instructions 18 Product description 18 How to order (Basic type) 18 Specification 19 Equivalent size 19 Mass 20 Precautions on model selection 21 Effective torque 23 Calculation formulae for moment of inertia 24 Kinetic energy / Rotation time 24 Allowable kinetic energy

Ekhagsvgen 29-31, S-14105 Huddinge Phone: 08-603 07 00, Fax: 08-603 07 10 Ireland SMC Pneumatics (Ireland) Ltd. 2002 Citywest Business Campus, Naas Road, Saggart, Co. Dublin Phone: 01-403 9000, Fax: 01-464 0500 Portugal SMC Espaa (Sucursal Portugal), S.A.

Size Order no. 27 16 LE-D-2-7 25 LE-D-19-3 32 LE-D-19-4 Replacement Parts/Grease Pack Applied portion Order no.

31 31 16 13 13 13 37 42.5 34.5 30 24 47.3 37 37 30 108 82 80 80 7 5.5 5.5 5 22 17 17 13 41 32 32 26 6 6 5 8 8 8 50 45 45 41 24 22 22 18 31 26 26 26 75 75 75 66 60 60 60 M26 x 1.5 M26 x 1.5 M20 x 1.5 174 140 138 134 17.5 17.5 19.5 15.5 35.5 26-0.033 0 7 7 7 5 4 4 1/4 1/8 1/8 14 12 10 16 13 13 45 41 41 35.5 26-0.033 0 17.5 19.5 35.5 32-0.039 0 21 82 36 10 8 M32 x 2 21.5 41.5 19 Air cylinder

After checking the detection position, tighten M3 screws to fix the auto switch so that the bottom of the auto switch contact the cylinder tube. (The tightening torque of the M3 screw must be 0.5 to 0.7Nm.) Tighten the auto switch mounting screw(M4) to fix the auto switch mounting bracket.

QW RW S T W X Y Z Bore size (mm) 32 CXW 60 33 140 19 157 33 10.5 7.5 40 84 35 180 21 187 39.5 11 8 Note) Rc, NPT and G ports can be selected.

(Fixed SI unit [l/min, or l, m3 or m3 x 103] will be set for switch types without unit switching function.) Refer to the specifications of display unit for the flow rate value per pulse.

(Fixed SI unit [(l/min, or l, m3 or m3 x 103)] will be set for switch type without the unit switching function.) Note 3) The high flow rate type is CE marked; however, the linearity with applied noise is 5% F.S. or less. Note 4) Switch output and accumulated pulse output selections are made using the button controls.

Bracket Mounting Procedure q Fit the bracket to the groove at the connector block (end block). w Tighten the screws (Tightening torque M3: 0.6 Nm). Tighten the screws (Tightening torque M3: 0.6 Nm). Note) The bracket can be mounted on the block with the mounting nut (Metric size: M3) only.

Cool from 30C (303 K) to 20C (293 K). : Tap water Density g: 1 x 103 kg/m3 Specific heat C: 4.2 x 103 J/(kgK) Water bath * Refer to the information shown below for the typical physical property values by circulating fluid.

(23) 54 2) 46 (37) 49 (44) 41 (36) 68 0.5 63 (57) 57 (51) 46 (43) 82 0.1 0.2 6 0.3 43 (34) 39 (30) 35 (28) 54 2) 49 (41) 53 (50) 47 (43) 68 0.5 67 (64) 61 (59) 54 (51) 81 1) ( ) 2) ZQ05A0.35MPaZQ07AZQ10A0.43MPaZQ000A0.4MPa 3) (PD) V PD [MPa] ZQ05A ZQ07A ZQ10A ZQ000A 0.05 11 10 8 16 0.15 22 20 17 32 3.2 0.25 31 29 24 46 0.35 44 39 31 60 0.45 54 48 38 74 0.05 11 11 9 16 0.15 24 22 18

Purge air flow rate (L/min [ANR]) 180 Existing model 160 Reduction ratio 140 31% IDG50A New New 120 Purge air flow rate (rated conditions) 100 80 Model Purge air flow rate Purge ratio Running cost 60 (L/min [ANR]) (%) (yen/year) 40 46,440 15 86 IDG50A New New 0 Existing model 67,500 20 125 0.0 0.5 1.0 [Calculation conditions] Air unit price: 3 yen/m3 Operating hours: 12 hours/day Annual operating

M3 x 0.5 x 3L M8 x 1.25 x 8L (Bolt holder) (Hexagon socket head set screw) 31 0.5 45 45 3 3 5.3 5.3 250.2 250.2 16 32 2-M3 x 0.5 through 6.5 counter bore depth 5 (Same on the opposite side) 3.4 through 3 3 45 45 5.5 M2.5 x 0.45 x 6L (Cap screw) M3 x 0.5 x 12.5L (Hexagon bolt) and M3 x 0.5 (Hexagon nut) 2-M3 x 0.5 through Steel ball Plug 2-M3 x 0.5 through 2.75 (11) (10+ST) 250.2 4 Part no

M5 x 18 Tightening torque 4.4Nm0.2Nm M3 x 14 Pulley cover mounting process Pulley cover TP-M3 x 5 TP-M3 x 5 Pulley cover mounting process 1. Mount the pulley cover using thin head screws. Confirm there is no rattle on the pulley cover. 19 Electric Actuator/Maintenance Guide 4 Be sure to read before handling.