max (from 3 of graph MY2H/M3) = 60 (Nm) MX M3 = m3 x g x X = 7.525 x 9.8 x 140.1 x 10-3 = 10.33 (Nm) m3 M3 MTS Load factor 3 = M3/M3 max = 10.33/60 = 0.17 MY 5.
x 0.5 with depth 3.5 10 9 + ST 2.7 8 6.7 2-M3 x 0.5 with depth 3 (Piping port) 20 20.5 5.5 42 + ST ST 5.5 4.5 32 + ST 13.4 5 + ST 2.75 11 12 1.2 M3 x 0.5 x 3 (Hexagon socket head set screw) M8 x 1.25 x 7.5 (Bolt holder) 3.8 3.8 0.5 45 45 3 3 25 0.2 25 0.2 5.3 5.3 32 31 16 2-M3 x 0.5 through 3.4 through 6.5 counterbore with depth 5 (Opposite side: Same) 3 3 45 45 5.5 2-M3 x 0.5 through M2.5
G 28 58 5H9 +0.030 0 depth 5 (5.5) 10 D-M4 x 0.7 (for work piece mounting) 10.5 12 2-M3 thread depth 5 (3.5) 6 4-8 50 18.5 10 20 17.5 22 25 35 (5) 62 72 12 (15) (6) 8 1 0.2 31 5H9 +0.030 0 depth 5 Photo micro sensor wire (300mm) 10 13 1.5 [5.5] 6 25 (4) 30.5 10 (39.5) E Motor wire (300mm) Stroke + 135 The dimension inside [ ] shows the location at which the home position switch operates
27 30 1 4 3 8 30 30.5 17 KAT10-U02 KAT10-U03 26.5 18.5 17 10 21 29.0 29.0 1 2 KAT10-U04 30 31.5 51 31 34 22 1 4 3 8 27 28 31.5 32.5 KAT12-U02 KAT12-U03 17 20.9 17 12 28.5 22 45.2 45.2 1 2 KAT12-U04 31 33.5 22 54 Reference dimensions after Uni thread installation.
27 30 1 4 3 8 KAT10-U02 KAT10-U03 30 30.5 17 10 26.5 18.5 17 21 29.0 29.0 1 2 KAT10-U04 30 31.5 51 31 34 22 1 4 3 8 KAT12-U02 KAT12-U03 27 28 31.5 32.5 17 12 20.9 17 28.5 22 45.2 45.2 1 2 KAT12-U04 31 33.5 22 54 Reference dimensions after Uni thread installation.
8 13.2 10.2 16.4 30.1 21.5 39.7 14.2 16 AS231FSG1-G02-04 4 13.2 24 17.5 35.7 43.8 42.4 38.3 36.9 13.3 21.5 16.2 7.2 9.6 12 1/8 13 27 AS231FSG1-G02-06 6 10.4 19 33.8 21.4 43.9 29 AS231FSG1-G02-08 8 13.2 34.9 23.5 46 14.2 30 AS231FSG1-G02-10 10 15.9 20.9 38.1 24.7 47.3 15.6 31 AS331FSG1-G02-06 6 8.2 16.5 29.9 17.5 40.1 49.7 48.3 43.2 41.8 13.3 24.5 19.2 1/4 17 12.9 13 56 AS331FSG1-G02-08 8
Coordinates and Moments z M3: Yawing M1: Pitching y x M2: Rolling Static moment Ceiling mounting Horizontal mounting Wall mounting M1 M2 M2 M1 M2 M3 y X x Y y z X x Y X x Z m1 x g m2 x g m3 x g Vertical mounting Mounting orientation Horizontal Ceiling Wall Vertical m1 m2 m3 m4 Static load m M3 M1 m1 x g x X m2 x g x X m4 x g x Z Static moment M1 m1 x g x Y m2 x g x Y m3 x g x Z y z M2 z Y
MXF12 0.47 M2.5 x 8 MXF16 0.88 M3 x 10 MXF20 M4 x 14 2.06 Loctite No. 242 of Henkel Japan Ltd. or its equivalent is applied. 1-7.
(Fixed SI unit [l/min, or l, m3 or m3 x 103] will be set for switch types without unit switching function.) Refer to the specifications of display unit for the flow rate value per pulse.
782 MXS 1322Air Slide Table Dimensions: MXS8 1322Basic 2 x M3 x 0.5 thread depth 4 Operating port 2 x M5 x 0.8 7 2 Vacuum suction port M5 x 0.8 5.5 J 6 Max. 9.5 (Stroke adjuster at retraction end) I 8 6.5 4 6.5 7 7 3.5 3.8 NA x M3 x 0.5 thread depth 4 14.6 K 7 3.8 KA 14.6 22 (With stroke adjuster at extension end) Stroke adjuster at extension end Stroke adjuster at retraction end N x M3 x
(ANR) oil mist concentration (before saturated with hydraulic fluid: 0.01mg/m3 (ANR) or less, approx. 0.008ppm ) Note 1) Pressure gauge connection threads are not required for the regulator with a square embedded type pressure gauge (AWD20 to 40).
common 31 slave mode I iso ated comrnon As.lnlerhce 4in/21'jrt 31 slavE riode I ho aled con',1ron Wnhod Sl unitinpui block {SDo) Nole 1 ) Indimie the size in lt'e specinton sheel n ihe Ese oi CM and L^r Note 2l Symbols ior inch s zes are
With One-touch fitting Port size U01 Uni 1/8 U02 Uni 1/4 U03 Uni 3/8 U04 Uni 1/2 Needle Valve/Flow Rate Characteristics AS2201F-U02, AS2211F-U02 AS2301F-U02, AS2311F-U02 AS2201F-U01, AS2211F-U01 AS2301F-U01, AS2311F-U01 600 300 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 06, 07, 08, 09, 10 500 08, 09, 10, 11 Flow rate L/min (ANR) Flow rate L/min (ANR) 03, 04 06, 07 200 400 01, 23 300
31 31 16 13 13 13 125 46.5 37.5 33.5 28 7 5.5 5.5 5 M14 x 1.5 M10 x 1.25 M10 x 1.25 M8 x 1.25 15 11.5 10.5 8.5 40 32 25 20 66 60 60 60 75 75 75 24 22 22 18 22 17 17 13 41 32 32 26 31 26 26 26 50 45 45 41 174 140 138 134 M26 x 1.5 M26 x 1.5 M20 x 1.5 21 19.5 19.5 15.5 17.5 17.5 35.5 35.5 26-0.033 0 14 12 10 16 13 13 7 7 7 5 4 4 1/4 1/8 1/8 163 131 129 26-0.033 0 17.5 35.5 32-0.039 0 10 8
( 0.8 ppm) [AFD] Max. 0.1 mg/m3 (Before saturated with oil 0.01 mg/m3 or less 0.008 ppm) Compressed air purity class*5 [AFM] ISO 8573-1:2010 [ 3 : 7 : 3 ]*6 [AFD] ISO 8573-1:2010 [ 1 : 7 : 2 ]*7 Drain capacity 8 cm3 25 cm3 45 cm3 Bowl material Polycarbonate Bowl guard Semi-standard (Steel) Standard (Polycarbonate) Weight 0.10 kg 0.18 kg 0.37 kg 0.40 kg *1 Inlet pressure: 0.7 MPa.
(Fixed SI unit [(l/min, or l, m3 or m3 x 103)] will be set for switch type without the unit switching function.) Note 3) The high flow rate type is CE marked; however, the linearity with applied noise is 5% F.S. or less. Note 4) Switch output and accumulated pulse output selections are made using the button controls.
(Fixed SI unit [l/min, or l, m3 or m3 x 103] will be set for switch types without unit switching function.) Refer to the specifications of display unit for the flow rate value per pulse.
VK 31 Type How to Order Applicable solenoid valve (1) VZ SS3Y1 31 05 SY113-l-M3 SY113A-l-M3 SY123-l-M3 SY123A-l-M3 VT Stations 02 VT 2 stations ... ... Applicable blank plate assembly SY100-77-1A P R 20 stations VP 20 R port M5 X 0.8 P port M5 X 0.8 VG VP Note 1) SY113 (A) and SY123 (A) cannot be mounted on the same manifold.
How ttt Order Applicable valves Type 20 NVJ312-O-M3 NVJ3120-O-M3 NVJ322-O-M3 NVJ3220-O-M3 Type 20 and 2OR Internal pilot type NW3J3-2 External pilot type NVv3Jc-2oR@ Type 20 Type 208 Type 2OR NVJ312R-O-M3 NVJ322R-O-M3 |[0ldl!
How ttt Order Applicable valves Type 20 NVJ312-O-M3 NVJ3120-O-M3 NVJ322-O-M3 NVJ3220-O-M3 Type 20 and 2OR Internal pilot type NW3J3-2 External pilot type NVv3Jc-2oR@ Type 20 Type 208 Type 2OR NVJ312R-O-M3 NVJ322R-O-M3 |[0ldl!