SMC Corporation of America
Elite Part Number Search
Search Results "SS3YJ3-42-13-N3T"

Valve Mounting Direction: S (Single Solenoid Coil on the Same Side as A,B Ports), Piping: 41 (5 Port/Base Mounted Common SUP Common EXH), Stations: 13 Stations, A B Port Size: N3T (5/32" One-touch Fitting NPTF)

Valve Mounting Direction: S (Single Solenoid Coil on the Same Side as A,B Ports), Piping: 46 (5 Port/Base Mounted Common SUP Individual EXH), Stations: 13 Stations, A B Port Size: N3T (5/32" One-touch Fitting NPTF)

Valve Mounting Direction: Solenoid on the Side Opposite to A,B Ports, Piping: 32 (4 Port/Base Mounted Common SUP Common EXH), Stations: 13 Stations, A B Port Size: N3T (5/32" One-touch Fitting NPTF)

Valve Mounting Direction: Solenoid on the Side Opposite to A,B Ports, Piping: 41 (5 Port/Base Mounted Common SUP Common EXH), Stations: 13 Stations, A B Port Size: N3T (5/32" One-touch Fitting NPTF)

Valve Mounting Direction: Solenoid on the Side Opposite to A,B Ports, Piping: 46 (5 Port/Base Mounted Common SUP Individual EXH), Stations: 13 Stations, A B Port Size: N3T (5/32" One-touch Fitting NPTF)

Manifold Type: 41 (Base Mounted), Valve Stations: 13 Stations, A, B Port: N3T (5/32" One-touch Fitting NPTF)

Series: 1 (VQZ1000), Stations: 13 Stations, Port Size: N3T (5/32" One-touch Fitting), Option: R (External Pilot)

Description Qty. 4 Seal 1 4 Seal 1 4 Seal 1 4 Seal 1 12 Gasket 1 12 Gasket 1 12 Gasket 1 12 Gasket 1 Parts included 13 Gasket 1 13 Gasket 1 13 Gasket 1 13 Gasket 1 in seal kit 17 Wear ring 4 17 Wear ring 4 17 Wear ring 4 17 Wear ring 4 18 Piston seal 4 18 Piston seal 4 18 Piston seal 4 18 Piston seal 4 26 Seal washer 2 26 Seal washer 2 26 Seal washer 2 26 Seal washer 2 Description Size 70

Terminal part no. 1 10 2 11 3 12 4 13 5 14 6 15 7 16 8 17 9 18 A mark is located on the connector number 1 side. 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 LJ1 LG1 LC1 LX LC6D/LC6C Switches View from the insertion side View from the wiring side Switches Home position switch: This switch indicates the home position. Connect this switch when returning to the origin point.

Terminal part no. 1 10 2 11 3 12 4 13 5 14 6 15 7 16 8 17 9 18 A mark is located on the connector number 1 side. 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 View from the insertion side View from the wiring side Switches Home position switch: This switch indicates the home position. Connect this switch when returning to the origin point.

Weight Auto Switch Internal Circuit D-F7NV (g) D-F7NV D-F7PV D-F7BV Auto switch model DC (+) Brown 11 13 13 0.5 Lead wire length (m) 50 57 57 3 Main circuit of switch OUT Black 81 92 92 5 DC () Blue Dimensions 3.5 mounting hole D-F7PV Indicator light DC (+) Brown Main circuit of switch Main circuit of switch OUT Black DC () Blue D-F7BV OUT (+) Brown Most sensitive position OUT () Blue 7-9

8 18 [MODE], 13 OFF 6 , 8 , 13 17 8 12 11 22 5 18 +/, 16 , 40 - 11 , 18 , , 8 11 [RESET] 10ms 11 [HOLD] [BANK] [MODE] 13 RS-232C 12 RS-232C ,3 18 26 NO.

Applicable tubing size Connection tubing size Class 1 2 3 4 5 6 Symbol Connection tubing size Class 1 2 3 4 5 6 Symbol Inch sizes Metric sizes Class 03 05 07 11 13 19 25 03 04 06 08 10 12 19 25 1/8" x 0.086" 3/16" x 0.127" 1/4" x 5/32" 3/8" x 1/4" 1/2" x 3/8" 3/4" x 5/8" 1" x 0.886" 3 x 2 4 x 3 6 x 4 8 x 6 10 x 8 12 x 10 19 x 16 25 x 22.5 Symbol 1 2 3 4 5 6 LQ2 2 3 4 5 LQ1 11 12 13 14 15

18.5 22.5 44.5 49.5 47 43.5 50 58 82 85 88.5 D-F9ll 7 16 20 42 47 44.5 42.5 49 57 81 84 87.5 D-F9lWl 6 15 19 41 46 43.5 4.4-16

Valve model Port size VCS21 VCS20-12-01 1/8, 1/4 34 40 25 30 12.8 12.8 5 4.5 6 13 VCS30-12-02 1/4, 3/8 42 52 30 40 19 19 6 5.5 7 19 VCS31 VCS30-12-04 1/2 48 56 36 44 23 23 6 5.5 7 23 VCS40-12-02 1/4, 3/8 42 52 30 40 23 23 6 5.5 7 19 VCS30-12-04 VCS41 1/2 48 56 36 44 23 23 6 5.5 7 23 VCS40-12-06 3/4 56 65 44 53 28.2 28.2 6 5.5 7 26 Bracket material: Stainless steel 3 Series VCS Direct Operated

For details, refer to LECYM Operation Manual,section 3.3.2. 13 - 2.3.2 Sequence Input Circuit (1) Photocoupler Input Circuit CN1 connector terminals 6 to 13 are explained below. The sequence input circuit interface is connected through a relay or open-collector transistor circuit. When connecting through a relay, use a low-current relay.

(Max. 33) 13 (Max. 38) With low load shock absorber + Adjusting bolts MY1W Bore size Stroke L TT h h E F EA h EB W F Stroke adjusting unit S (Shock absorber stroke) T MY1W16, 20 F MY1W50, 63 Shock absorber EC EY h 3.6 3.6 3.5 4.5 4.5 5.5 5.5 TT 5.4 (Max. 11) 5 (Max. 11) 5 (Max. 16.5) 8 (Max. 20) 9 (Max. 25) 13 (Max. 33) 13 (Max. 38) S 40.8 40.8 46.7 67.3 67.3 73.2 73.2 E 14.6 20 24 29 35

Workpiece mass: 0.05 kg Pressure 0.6 MPa 30 0.5 25 0.4 Gripping force (N) 20 0.3 15 13 0.2 10 0.1 5 0 20 30 50 60 40 70 Gripping point L (mm) When MHY2-16D is selected, the gripping force is determined to be 13 N according to the gripping point distance (L = 35 mm) and the pressure (0.4 MPa).

L M9NL Refer to page 12-13-1 for further information on auto switches. Auto switches marked with a "" are made upon receipt of order.