/ 4 W 24 VDC/ 4 W 12 VDC/ 4 W 24 VDC/ 4 W 12 VDC/ 6 W 24 VDC/ 6 W Electric specifications 8.4 VDC (Rated 35%)/ 0.8 W Allowable voltage fluctuation*5 10% of rated voltage (0 to +10%) Type of coil insulation Class B 5 VDC (Rated 42%)/ 0.7 W 10 VDC (Rated 42%)/ 0.7 W 5 VDC (Rated 42%)/ 0.7 W 10 VDC (Rated 42%)/ 0.7 W 4.2 VDC (Rated 35%)/ 0.8 W Holding*2 Holding voltage/ Power consumption *1

6 12 VDC V 6 VDC S 5 VDC R 3 VDC F G Supply valve/Release valve combination Pilot valve J K Supply valve Nil DC: 1 W (With indicator light: 1.5 W) AC Supply valve and release valve A Supply valve (N.O.)

VK300-82-2-01 VK300-82-2-03 110 VAC 110V 200 VAC 200V VK300-82-2-02 VK300-82-2-04 220 VAC 220V VK300-82-2-07 VK300-82-4-51 VK300-82-4-06 VK300-82-3-05 VK300-82-3-53 240 VAC 240V 6 VDC 6V 12 VDC 12V 24 VDC 24VD 48 VDC 48VD 3-2-11

VQZ Note) Rubber seal only 3-position closed center 2(B) (A)4 Coil voltage SQ 3 24 VDC 12 VDC 5 Note) 6 (R1)5 1 (P) 3(R2) VFS Note) Only 24 VDC is available with the S kit. 3-position exhaust center D Slide locking type (Manual) VFR 2(B) (A)4 Light/surge voltage suppressor 4 VQ7 Yes None (Non-polar) Nil E Note1, 2) (R1)5 1 (P) 3(R2) Note 1) Not applicable to the S kit.

0.01 to 0.1 VDC 3.7 to 4.3 mA DC 0.02 to 0.2 mA DC 1 to 5 VDC 0 to 10 VDC 4 to 20 mA DC 0 to 20 mA DC 0.7 0.7 0.6 0.6 0.5 0.5 0.4 0.4 Note 1) Enter symbols above in VY1D00-.

The proof pressure is double the operating pressure range. 0 0.25 0.5 1 2 5 Response time [s] 6 LFE Series Internal Circuits and Wiring Examples (Integrated Display Type) NPN 2 output type LFElAlll PNP 2 output type LFElBlll Brown DC (+) Brown DC (+) Load Black OUT1 Black OUT1 Main circuit Main circuit Load Load 24 VDC 24 VDC White OUT2 White OUT2 Load Blue DC () Blue DC () Max. 28 V, 80

: Analog output 1 to 5 V Allowable load resistance 100 k or more P5: Analog output 4 to 20 mA Allowable load resistance 300 or less (12 VDC), 600 or less (24 VDC) P2: Analog output 1 to 5 V Allowable load resistance 100 k or more P6: Analog output 4 to 20 mA Allowable load resistance 300 or less (12 VDC), 600 or less (24 VDC) 339 LLB Series Refer to the operation manual for how to set

LED of COM A-D does not light up if the port is not set to be "used" by input point setting. 24 VDC 24 VDC 24 VDC 17 16 Display/ Switch Setting (continued) Switch setting Make sure that switch setting is performed with power supply turned off. Open the cover, and set DIP switch with a small flat blade screwdriver, etc. UNIT STATUS setting (switch No.8) The setting is as follows.

Voltage Symbol Type 5 24 VDC 6 12 VDC Note) For symbol, refer to page 741.

ZNR ZNR 12 to 24 VDC SOL DC () 100 to 200 VAC SOL 2 DC () ZSE ISE 2 ( ) PNP open collector output Conduit terminal DIN type connector With indicator light AC Circuit Conduit terminal With indicator light DC circuit PSE DC (+) 1 ( ) 1 DC (+) MAX 80 mA Rectifying device Z I SE3 OUT Load 12 to 24 VDC ZNR ZNR 100 to 200 VAC 12 to 24 VDC SOL SOL DC () PS 2 ( ) LED 2 DC () indicator light Z I

10% with 10% voltage ripple or less When used as an IO-Link device 18 to 30 VDC, including ripple (p-p) 10% Temperature characteristics 2% F.S. (25C standard) 3% F .S.

100/150 Rated load voltage 48 VAC or less/30 VDC or less Maximum load current 500 mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal HRSH 090 HRSH To the thermo-chiller Users equipment side HRSE 7 24 VDC 6 24 VDC output (500 mA MAX) 5 HRZ 15 14 HRZD 24 VCOM output 13 24 VCOM HRW Signal description Default

30 VDC or less Maximum load current 500 mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k 11 Run/

or less Maximum load current 500 mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k 11 Run/stop signal

kW Input signal Rated load voltage 48 VAC or less/30 VDC or less Maximum load current 500 mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (not usable for inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting

D-P5DWL Auto switch model Applicable load 24 VDC relay, PLC Load voltage 24 VDC (20 to 28 VDC) Load current 6 to 40 mA or less Internal voltage drop 5 V or less Leakage current 1 mA or less at 24 VDC Operating time 40 ms or less Operating positionRed LED lights when ON. Optimum operating positionGreen LED lights when ON.

Features 4 PC Wiring System e-con Type Series PCW-EC Common Specifications Rated voltage 24 VDC Power supply line 2 A Rated current Communication line 0.3 A Insulation resistance 5 M or more at 100 VDC Withstand voltage 500 VAC Impact resistance 500 m/s2 Screw tightening torque 0.4 to 0.6 Nm/0.4 to 0.7 Nm Terminal block specifications Wire stripping length (recommended) 7 mm Connecting wire

The 24 VDC power supply for the controller (CN1), and the 24 VDC power supply for the parallel I/O (CN5) should be separate. 42 Parallel I/O connection check The wiring and connections and the signal status of the controller and PLC can be checked using the I/O status and Manual Output functions.

or less Maximum load current 500 mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k 11 Run/stop signal