3% F.S. or less1000 VAC for 1 min. (between live parts and case)50 M or more (at 500 VDC by megameter) between live parts and case01: R 1/8, M5 x 0.8 T1: NPTF 1/8, M5 x 0.80X: With suction filter (For mounting on ZX unit) 0R: Base mount type (For mounting on ZR unit)35 g (Including 0.6 m-Long lead wire)Oil-resistant vinyl cabtire code 3 cores, ?
3% F.S. or less1000 VAC for 1 min. (between live parts and case)50 M or more (at 500 VDC by megameter) between live parts and case01: R 1/8, M5 x 0.8 T1: NPTF 1/8, M5 x 0.80X: With suction filter (For mounting on ZX unit) 0R: Base mount type (For mounting on ZR unit)35 g (Including 0.6 m-Long lead wire)Grommet typeConnector typeCompliant with CE marking
3% F.S. or less1000 VAC for 1 min. (between live parts and case)50 M or more (at 500 VDC by megameter) between live parts and case01: R 8, M5 x 0.8 T1: NPTF 1/8, M5 x 0.8 00: ZM ejector mount type40 g (Including 0.6 m-Long lead wire)Oil-resistant vinyl cabtire code 3 cores, ?
3% F.S. or less1000 VAC for 1 min. (between live parts and case)50 M or more (at 500 VDC by megameter) between live parts and case01: R 1/8, M5 x 0.8 T1: NPTF 1/8, M5 x 0.80X: With suction filter (For mounting on ZX unit) 0R: Base mount type (For mounting on ZR unit)35 g (Including 0.6 m-Long lead wire)Oil-resistant vinyl cabtire code 3 cores, ?
3% F.S. or less1000 VAC for 1 min. (between live parts and case)50 M or more (at 500 VDC by megameter) between live parts and case01: R 8, M5 x 0.8 T1: NPTF 1/8, M5 x 0.8 00: ZM ejector mount type40 g (Including 0.6 m-Long lead wire)Oil-resistant vinyl cabtire code 3 cores, ?
3% F.S. or less1000 VAC for 1 min. (between live parts and case)50 M or more (at 500 VDC by megameter) between live parts and case01: R 8, M5 x 0.8 T1: NPTF 1/8, M5 x 0.8 00: ZM ejector mount type40 g (Including 0.6 m-Long lead wire)Oil-resistant vinyl cabtire code 3 cores, ?
3% F.S. or less1000 VAC for 1 min. (between live parts and case)50 M or more (at 500 VDC by megameter) between live parts and case01: R 8, M5 x 0.8 T1: NPTF 1/8, M5 x 0.8 00: ZM ejector mount type40 g (Including 0.6 m-Long lead wire)Oil-resistant vinyl cabtire code 3 cores, ?
3% F.S. or less1000 VAC for 1 min. (between live parts and case)50 M or more (at 500 VDC by megameter) between live parts and case01: R 8, M5 x 0.8 T1: NPTF 1/8, M5 x 0.8 00: ZM ejector mount type40 g (Including 0.6 m-Long lead wire)Oil-resistant vinyl cabtire code 3 cores, ?
3% F.S. or less1000 VAC for 1 min. (between live parts and case)50 M or more (at 500 VDC by megameter) between live parts and case01: R 8, M5 x 0.8 T1: NPTF 1/8, M5 x 0.8 00: ZM ejector mount type40 g (Including 0.6 m-Long lead wire)Oil-resistant vinyl cabtire code 3 cores, ?
3% F.S. or less1000 VAC for 1 min. (between live parts and case)50 M or more (at 500 VDC by megameter) between live parts and case01: R 1/8, M5 x 0.8 T1: NPTF 1/8, M5 x 0.80X: With suction filter (For mounting on ZX unit) 0R: Base mount type (For mounting on ZR unit)35 g (Including 0.6 m-Long lead wire)Oil-resistant vinyl cabtire code 3 cores, ?
Type: 332 (Body Ported), Valve Option: Standard Type, Rated Voltage: 3 (110 VAC, 50/60 Hz), Electrical Entry: D (DIN Terminal), Light/Surge Voltage Suppressor: None, Port Size: M5 (M5 x 0.8), Thread: Rc with sub-plate, or Nil, Bracket: F (w/Bracket, Not Assembled)
Type: 332 (Body Ported), Valve Option: Standard Type, Rated Voltage: 3 (110 VAC, 50/60 Hz), Electrical Entry: D (DIN Terminal), Light/Surge Voltage Suppressor: Z [w/Light/Surge Voltage Suppressor (Type D Only)], Port Size: M5 (M5 x 0.8)
Type: 332 (Body Ported), Valve Option: Standard Type, Rated Voltage: 1 (100 VAC, 50/60 Hz), Electrical Entry: D (DIN Terminal), Light/Surge Voltage Suppressor: Z [w/Light/Surge Voltage Suppressor (Type D Only)], Port Size: M5 (M5 x 0.8)
Type: 332 (Body Ported), Valve Option: Standard Type, Rated Voltage: 3 (110 VAC, 50/60 Hz), Electrical Entry: D (DIN Terminal), Light/Surge Voltage Suppressor: Z [w/Light/Surge Voltage Suppressor (Type D Only)], Port Size: M5 (M5 x 0.8), Thread: Rc with sub-plate, or Nil, Bracket: F (w/Bracket, Not Assembled)
Type: 332 (Body Ported), Valve Option: Standard Type, Rated Voltage: 7 (240 VAC, 50/60 Hz), Electrical Entry: D (DIN Terminal), Light/Surge Voltage Suppressor: None, Port Size: M5 (M5 x 0.8), Thread: Rc with sub-plate, or Nil, Bracket: F (w/Bracket, Not Assembled), CE-Compliant: Q (CE-compliant)
Type: 332 (Body Ported), Valve Option: Standard Type, Rated Voltage: 4 (220 VAC, 50/60 Hz), Electrical Entry: D (DIN Terminal), Light/Surge Voltage Suppressor: None, Port Size: M5 (M5 x 0.8), Thread: Rc with sub-plate, or Nil, Bracket: F (w/Bracket, Not Assembled), CE-Compliant: Q (CE-compliant)
Usage 2 x 3 CK-P04 Knuckle pin Clevis pin 4 4 57 Note) Cotter pins and flat washers are attached to the pin as a standard. 430 CK1 Series Options Limit Switch Mounting Base/Dog Fitting 50 75 Material: Rolled steel 4 x M5 x 0.8 17.3 58.7 5 30.2 Part no.
D-Z73 D-Y59B D-Y59A Load voltage 24 VDC,100 VAC 24 VDC (10 to 28 VDC) 28 VDC or less Load current range Indicator light Application Relay, PLC 24 VDC Relay, PLC IC circuit, Relay, PLC 5 to 40 mA, 5 to 20 mA 5 to 40 mA 40 mA or less PLC: Programmable Logic Controller Refer to page 889 for the applicable auto switch list.
Kalrez 6.5 x 10 7 6.5 x 10 11 External leak Note 2) (Pam3/s) Gate part 5 to 150 Operation temperature Note 3) (C) Actuator part 5 to 60 Inert gas Fluid 0.6 to 1 Operating time Note 4) (s) FKM, Kalrez 4079 (Option) Seal material Bellows AM350 Gate A6063 Main material of vacuum part Body A5052 Bonnet A5052 Others Stainless steel 304 Exhaust direction Free Mounting direction Vertical Port size M5
The settings of the master pressur, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, AA, ISE40/50/60 M5 PT VERSION, .43632 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay accuracyIndicator