mA) Output signal Ambient temperature Operating: 0 to 50C Stored: 10 to 60C Ambient humidity Operating, Stored: 35 to 80%RH (No condensation) Material Case: ABS/PBT/Stainless steel Emitter: Tungsten Impact resistance 100 m/s2 Applicable standard/directive CE (EMC directive: 2014/30/EU) *1: Based on ANSI/ESD-STM3.1-2006 standards Weights AC Adapter Specifications Input voltage 100 to 240 VAC
level input 10 ms or more, Low level 0.4 V or less 1 T U O U O T2 T E S Indicator light (Green/Red) Enclosure IP40 Operating temperature range 5 6 7 8 10.4 16 Operating: 0 to 50C, Stored: 10 to 60C (with no freezing or condensation) 8 x M3 11 (4.5) 19.4 29 Operating humidity range 21.4 Operating/Stored: 35 to 85% RH (with no condensation) Environmental resistance Withstand voltage 1000 VAC
Switch connection side: 0.5 m 100 VAC Load connection side: 0.5 m 24 VDC 3. Contact protection box internal circuit Mounting Warning CD-P11 Brown lead wire Surge absorber Choke coil 1. Do not use the switch unless the equipment operates normally.
Body Size: 2000, Thread: F (G), Port Size: 02 (1/4), Option: BS (w/Bracket, Silencer), Voltage: 3 [110 VAC (115 VAC)], Lead Wire: Y (Type Y, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: B (Push-turn Locking Slotted Type), Flow Direction/Pressure Unit: R (Flow Direction: Right to Left)
Body Size: 2000, Thread: N (NPT), Port Size: 02 (1/4), Option: S (Silencer), Voltage: 3 [110 VAC (115 VAC)], Lead Wire: D (Type D, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)
Body Size: 2000, Thread: F (G), Port Size: 02 (1/4), Option: B (w/Bracket), Voltage: 3 [110 VAC (115 VAC)], Lead Wire: Y (Type Y, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: B (Push-turn Locking Slotted Type), Flow Direction/Pressure Unit: R (Flow Direction: Right to Left)
Body Size: 2000, Thread: N (NPT), Port Size: 02 (1/4), Option: None, Voltage: 3 [110 VAC (115 VAC)], Lead Wire: D (Type D, DIN Terminal w/Connector), Surge Suppressor: None, Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: RZ (Flow Direction: Right to Left; Name Plate and Pressure Gauge in Imperial Units)
Body Size: 2000, Thread: F (G), Port Size: 02 (1/4), Option: None, Voltage: 3 [110 VAC (115 VAC)], Lead Wire: Y (Type Y, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: B (Push-turn Locking Slotted Type), Flow Direction/Pressure Unit: R (Flow Direction: Right to Left)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: B (w/Earth Leakage Breaker)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: BJ (B + J)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: M (Applicable to Deionized Water Piping)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz]
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: B (w/Earth Leakage Breaker)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: BM (B + M)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: JM (J + M)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: M (Applicable to Deionized Water Piping)
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz]
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz]
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: B (w/Earth Leakage Breaker)
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: JM (J + M)