<br>VBAT series products compliant with CE-marking, Chinese pressure vessel regulations, and ASME standards as well as those not compliant with ASME standards are listed in the catalog.<br>Contact SMC about country-specific availability.<br>The VBAT series catalog can be found here.

<br>Both the KQG2 and KQB2 variations have the same dimensions. In addition, the full part numbers are laser-printed onto both types of fittings for identification purposes.<br><br>

<br>There are no products that can reduce the size by 2 sizes. However, a KQG2R08-10 and a KQG2R06-08 reducer can be inserted into the KQG2L10-04S in series to reduce the size from ø10 to ø6.<br><br>

<br>(2) When the differential pressure between the IN and OUT sides is smaller than the min. operating pressure of the AQ series valve<br>(3) When the sonic conductance (C) of the AQ series valve’s IN side piping or solenoid valve is smaller than that of the AQ series valve itself

<br>When a maintenance warning occurs, the ionizer main unit will continue to operate, but it is necessary to clean the emitter or replace the emitter assembly. In order to clear the alarm, remedy the cause of the error, and then reset the discharge stop signal input or power supply.<br><br>

<br>Connect the numbers on the connector body in the following manner: 1 to +24 VDC (brown), 2 to 0 V (blue), 3 to F.G. (green), and 4 to the error signal (purple). <br>However, for IZF21/31 series ionizers, the power cable connector cannot be ordered individually.<br>Instead, replace the power cable as a whole with the part number “IZS41-CP□.”

<br>New IZN10E series ionizers are lighter and shorter in overall length, but the mounting dimensions are the same as those of the old IZN10 series.<br>The installed power cables and brackets can be used as is.<br>Note) The emitter assembly, body assembly, and cartridge assembly are not interchangeable.

<br>For example, for analog output 1 to 5 VDC types, the flow rate at 1 V may be 0 or it may be the min. rated flow rate. <br>In addition, for some models, the flow rate at 5 V may be the max. rated flow rate or it may be possible to change the flow rate. <br>Note) For PF2A series flow switches, the flow rate at 1 V/4 mA is the min. rated flow rate.