SMC Corporation of America
Elite Part Number Search
Search Results "RDLQB32TF-75-B"

1.0 0 2 6 4 8 1.0 100 0 25 50 75 10 Input signal (%F.S.)

-LD Piping port P Operating direction A 7 Piping port P Operating direction B W K G With switch rail Q + Stroke Z + Stroke Piping port P (plug) Operating direction B HS CR HR Plug 22 8 Piping port P Operating direction B Piping port P (plug) Operating direction B 8 Piping port P Operating direction A 16 19.5 16 Plug REBR15 REBR15 (mm) A B C CB CR D F G GP GW H HA HB HC HP HR HS HT Model REBR15

(mm) Model Order no. d: Thread nominal size H B C JS10-4-070 JS16-5-080 JS20-8-125 JS32-10-125 JS40-14-150 JS63-18-150 M40.7 3.2 8.1 DA00127 7 M50.8 4 9.2 DA00128 8 d M81.25 5 15 DA00036 13 M101.25 6 19.6 DA06 17 C M141.5 8 25.4 DA00186 22 M181.5 11 31.2 DA00188 27 H B D-X Technical Data 1157 JS Series Dimensions JS10, 16 M M Center of sphere U D J U F B C E G P H A R Use the precision spanner

B IDFB4E to 15E A Power cable outlet 0.7 [17 mm] Grommet with membrane Signal cable outlet 0.7 [17 mm] Terminal block (Wire diameter 0.4 [9 to 11mm]) Grommet with membrane Power cable outlet 0.7 [17 mm] IDFB4E to 11E_Terminal block C D A B Terminal block Dimensions Unit: inch [mm] A B C D Model B B 9.0 [230] 2.6 [67] 7.0 [179] 1.3 [32] IDFB4E, 6E, 8E, 11E A Power cable outlet 0.7 [17 mm]

Bore size Standard stroke (mm) 40 30, 50, 75, 100 63 30, 50, 75, 100 100 30, 50, 75, 100 Applicable auto switches Lead wire length (m) Load voltage Auto switch model no.

N.O. 140 (80) 1/8 Base mounted (with sub-plate) 135 (75) 136 (76) 157 (97) V100 1/4 Note) Value for DC. Add 3 g for AC. ( ): Without sub-plate.

H B H C D CE1 29 29 31 34 34 34 39 39 39 44 44 48 53 57 62 72 34.6 34.6 37 41.6 41.6 41.6 47.3 47.3 47.3 53.1 53.1 57.7 63.5 69.3 75 86.5 30 30 32 36 36 36 41 41 41 46 46 50 55 60 65 75 12 12 13 14 14 14 16 16 16 18 18 20 21 23 25 29 5.5 7 8 10 13 13 17 17 17 19 19 19 22 24 24 27 2.4 3.2 4 5 5 5 6 6 6 7 7 7 8 10 10 11 6.4 8.1 9.2 11.5 15 15 19.6 19.6 19.6 21.9 21.9 21.9 25.4 27.7 27.7 31.2

B H H C D CE1 29 29 31 34 34 34 39 39 39 44 44 48 53 57 62 72 34.6 34.6 37 41.6 41.6 41.6 47.3 47.3 47.3 53.1 53.1 57.7 63.5 69.3 75 86.5 30 30 32 36 36 36 41 41 41 46 46 50 55 60 65 75 5.5 7 8 10 13 13 17 17 17 19 19 19 22 24 24 27 12 12 13 14 14 14 16 16 16 18 18 20 21 23 25 29 2.4 3.2 4 5 5 5 6 6 6 7 7 7 8 10 10 11 6.4 8.1 9.2 11.5 15 15 19.6 19.6 19.6 21.9 21.9 21.9 25.4 27.7 27.7 31.2

Normal output Reversed output P_1(P_2)=A-(A-B)/4 n_1(n_2)=B+(A-B)/4 A = Maximum pressure H_1(H_2)= (A-B)/2 H_1(H_2)= (A-B)/2 B = Minimum pressure If setting is not necessary press the UP and DOWN buttons simultaneously for 1 second or longer. -46No.PS-OMW0012-C [F 6] Fine adjustment of display value This function is to manually perform a fine adjustment of the displayed pressure value.

Signal cable 16.4 ft (5 m) Circulating fluid outlet 5.9 (150) 4.8 (122) 1.1 (29) 3.0 (75) 1.2 (30) 13.8 (350) 0.8 (20) DC cable 16.4 ft (5 m) Model no. label (Controller) Alarm output connector 5.5 (140) Terminal block Display panel 8.7 (222) 7.4 (187) SI AL OUT 7.0 (177) Purge inlet (M5) 3.0 (75) 8.5 (215) FG B B A FG + EXT.SENSOR REMOTE ON/OFF CHEMICAL Fluid leak sensor 3.1 (79) PURGE OUT

The port on the piston rod B side for 10-/12-, 21is plugged since unlike the vacuum, it is not necessary to exhaust from 2 ports.

B) In the state of A), attach the workpiece and the arm side block, and adjust the shim so that there is a space of about 0 mm. During this step, theoretically, there is no clamping force pressing down on the workpiece. C) In order to generate a clamping force from the state described in step B), insert an additional shim.

CL CL1 Rod Side Flange Style Bore size (mm) MLGC B BZ FT FD FX FZ FY Rod side flange style: CLG1FN Head side flange style: CLG1GN 25 30 30 36 65 75 75 82 38 45 45 52 52 60 60 66 5.5 5.5 6.6 6.6 57.5 6 7 7 8 20 25 32 40 CNG 69 69 76 MNB For long stroke, refer to page 9-2-32.

MY-S25 MY-S32 MY-S40 Applicable cylinder A 105 130 145 B 119 148 167 C 35 45 55 D 50 64 80 E 8 11.7 14.8 F 5 6 8.5 G 9.5 11 14 H 5.5 6.6 9 J M6 x 1 M8 x 1.25 M10 x 1.5 A B A B A B MY1H25 MY1H32 MY1H40 MY1 HT Side supports consist of a set of right and left supports.

Pressure gauge port M Q N F J K P E Bracket (option) AR50, 60 Port size Square embedded type pressure gauge (option) A D C L OUT IN G Pressure gauge (option) B Pressure gauge port M N Bracket (option) Q K P F E J Standard specification Accessory specification With pressure gauge Bracket mounting size Panel mount Model Port sizes A 25 40 53 53 70 75 90 95 J 25 30 30 41 50 50 70 70 B 58 94

D-F5NTL 1 10 D-F5W D-J59W D-F5BAL D-F5F D-F5LF 2 (On different faces or same face) 15 130 125 120 90 70 25 75 10 1 1.12-14

Double acting PA PA B A PB B A With by-pass Suck back valve Manual Operation-Series LVH N.C. Double acting P PA PA Locking and non-locking types available B A B A PB B A Integral fitting type/Threaded type Manifolds Main applications and fields For shut off For air bleeding N.C.

(kg) -E 0.21 0.21 0.21 -EL 0.26 0.26 0.26 -M 0.27 0.27 0.27 -ML 0.32 0.32 0.32 Without switch 0.17 0.17 0.17 Model ZM2 ZM4 ZM6 ZM1-J ZM3-J ZM5-J ZM1-K ZM3-K ZM5-K ZM1-A ZM3-A ZM5-A ZM1-B ZM3-B ZM5-B ZM0.24 0.28 0.33 0.34 0.39 0.25 0.29 0.34 0.35 0.4 0.25 0.29 0.34 0.35 0.4 0.26 0.3 0.35 0.36 0.41 P Q 0.24 0.28 0.33 0.34 0.39 -04R/L 0.209 0.214 0.219 0.224 0.229 0.234 0.239 0.244 0.249 0.254

-Check the piping, and stop Large air consumption the leakage. 75-Air is leaking from the positioner. -Replace the pilot valve unit. (due to a seating failure of the pilot valve. ) 75-Others. -Contact SMC representatives. Automatic calibration -The angle of the feedback lever is -Refer to 2.