Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: F01 (G1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: Lead Wire w/Connector (2 m), Option: R (Bracket for w/o Flow Adjustment Valve: ZS-33-M

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: F01 (G1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: Z (w/o Lead Wire w/Connector)

[Separate Type Connector Connection] Separated sensor, Output Method: Analog, Analog Output Specification: Current, Pipe Port Type: [One-Touch Couplings] One-Touch Couplings (Straight), Plumbing Thread Type: -, Plumbing Thread Nominal: -, Pressure Resistance(MPa): 1, Flow Rate Type: Standard, Operating Temperature Range(°C): -10~60, Operating Humidity Range(%): 35~85, Number of Inputs: 2,

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: None, Calibration Certificate: w/Calibration Certificate, Connector: w/o Lead Wire w/Connector, Option: -

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment Valve: ZS-33-M

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: w/o Lead Wire w/Connector, Option: -

Flow Rate Range: 25 [0.5 to 25 (12.5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: None, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: Panel Mount Adapter for w/o Flow Adjustment Valve

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: None, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: Bracket for w/Flow Adjustment Valve

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: None, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/Flow Adjustment Valve

Flow Rate Range: 25 [0.5 to 25 (12.5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: None, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: None, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: Panel Mount Adapter for w/Flow Adjustment Valve

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: None, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -

Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: None, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: -

Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: None, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -

Dimensions 4 EXH port 1/8 Input signal port( PIL ) R port Supply pressure exhaust port 2 x 1/8 Output port 2( A ) Supply port on the other side 1( P ) 2 x M6 x 1 thread depth 8 (Panel mounting screw) Panel mounted Bracket mounted 2 x 6.5 hole (Mounting screw M6 x 1 x 12) Handle side 4 x M6 screw 4 x 7 hole on the bracket side Bracket plate thickness t = 2 Panel plate thickness t = 3 or less

SUP=0.2MPa 8 6 4 2 0 1 2 3 4 5 Cycle (Hz) Hz 14 3) Viscosity characteristics With reference to the viscosity characteristic graph (shown below), discharge amount of transported fluid with higher viscosity can be calculated.

1.41.6Nm 8 2 VR2110 3 01.0MPa 0.250.8MPa 0.560s (*) 10 (%) F.S. oC( -560 3/ (s C (dm 0.6 [1 (P) 2 (A) ] 0.5 [2 (A) 3 (R) ] bar) ) b 0.2 [1 (P) 2 (A) ] 0.15 [2 (A) 3 (R) ] Rc, NPT, G1/8 ON Delay 480g (*) 4 4 V R 2 1 1 0 01 01 Rc 1/8 N01 NPT 1/8 F01 F01 2 G 1/8 9 5 VR 1 ON Delay 0.560 () () 1 ON OFF 6 (1) 2 0.5MPa 2 10 (2) VR2110 3 )0.25MPa A 60sec (), (S) 0.8MPa 40sec

The warranty period of the product is 1 year in service or 1.5 years after the product is delivered, whichever is first.2) Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch. 2.

Specification NOTE The direct current power supply to be used should be UL approved as follows : Circuit (of class 2) which is of maximum 30Vrms (42.4V peak) or less, with UL 1310 class 2 power supply unit or UL 1585 class 2 transformer. The Pressure switch is a approved product only if it has a mark on the body.

Mounting direction is available in either horizontal or perpendicular. 16-9-2