Supply NC output NO output Exhaust of NC exhaust of NO Pilot tor NC Pilot for NO P A B R s z Y P A B R1 R2 z Y P A B EA EB PA PB 1 2 4 3 5 1 2 1 4 Table 7.2 Typical port identitications M O N O S T A B L E A N D B I S T A B L E Spring returned valves are monostable. They have a defined prefened position to which they automatically retum.
2(B) port M5 x 0.8, C4, C6 Flow Characteristics Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R) Port size 1(P), 5/3(R) port Manifold 2 (B), 4(A) port C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv 1/8 1/8 1/8 M5 x 0.8 C4 C6 0.46 0.62 0.79 0.39 0.33 0.36 0.12 0.16 0.21 0.75 0.83 0.91 0.32 0.27 0.36 0.19 0.20 0.24 Body ported For internal pilot Type VV5Z3-20 VZ32 Note) Value at manifold
C4 C6 C4 C6 Stations L1 L2 L3 L4 3 4 5 6 7 8 9 10 2 123 135.5 125 102 16.5 148 148 160.5 150 173 185.5 175 198 210.5 200 112.5 91.5 15.5 137.5 137.5 123 12.5 162.5 144 14.5 187.5 165 16.5 133.5 13.5 154.5 15.5 175.5 17.5 112.5 17.5 Stations SS5Y3-45GUBC4 C6 2 3 4 5 6 7 8 9 10 Stations L1 L2 L3 L4 135.5 125 108 13.5 148 160.5 150 129 15.5 173 185.5 175 150 17.5 185.5 175 198 210.5 200 223
SOL. location A B A B A B A B () A B () () 0 1 2 3 4 5 6 Double Double Single SI unit A side B side 3 position A B A B B A B A B A VQC Double Double Single SI unit A side B side 3 position Stations 1 2 3 4 5 SQ The places of asterisk are not used. 3 position uses two stations for wiring.
Series VZ3000/Body Ported Manifold Specifications Manifold Standard Manifold Specifications Type 20 Single base/B mount Common SUP/Common EXH 2 to 20 stations Valve Rc 1 8 Model Manifold type P(SUP)/R(EXH) Valve stations 4(A), 2(B) port location Port size 1(P), 3/5(R) port 4(A), 2(B) port M5 x 0.8, C4, C6 Flow Characteristics Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R) Port size
length of the return unit (mm) Unit construction Flow switch type Temp. sensor Flow range Port size A Symbol Flow adjustment valve Stop valve Nil 95 S 95 Nil P 139 1/2 Remote sensor/ W 139 (symbol 04) 5 to 40 L/min Integrated display type 3/4 (symbol 40) Nil 106 (symbol 06) S 106 Yes P 150 W 150 B: Total length of the supply unit (mm) Unit construction Flow range Port size B Symbol
Hs B 16 14 14 26 29 (36) D-C73C 8.5 A D-H7C 8.5 A Hs B B Hs 14 36.7 38.2 D-G5NT D-B5, B6 B A Hs Hs B A 24.5 24.5 13 33 13 33 Hs D-A3 D-G3, D-K3 B A 49 B Hs A 49 34 56 18 36 18 36 B D-A4 Hs A 34.5 56 18 36 Minimum Strokes for Auto Switch Mounting Minimum strokes are as follows based on the space required for mounting auto switches.
D-A59W D-Z7/Z80 D-M9/M9W D-M9A Bore size (mm) Bore size (mm) D-Z7/Z80 D-A5/A6 A B A B A B A B A B A B Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs 40 50 63 80 100 40 50 63 80 100 11.5 8.5 8 5 13 10 5 2 27 28.5 27 34 35.5 28.5 29 27 13 8 9.5 4.5 14.5 9.5 6.5 1.5 33 33.5 33 38.5 39.5 34.5 33 33 4.5 0 8.5 3.5 47.5 38.5 14.5 9.5 11 6 16 11 8 3 38.5 38 38.5 43.5 45 38.5 28 37 8.5 3.5 12.5 7.5 54
Hs B 16 14 14 26 29 (36) D-C73C 8.5 A D-H7C 8.5 A Hs B B Hs 14 36.7 38.2 D-G5NT D-B5, B6 B A Hs Hs B A 24.5 24.5 13 33 13 33 Hs D-A3 D-G3, D-K3 B A 49 B Hs A 49 34 56 18 36 18 36 B D-A4 Hs A 34.5 56 18 36 Minimum Strokes for Auto Switch Mounting (mm) 1in = 25.4mm Minimum strokes are as follows based on the space required for mounting auto switches.
Wn Weight mn X-axis Xn Y-axis Yn Z-axis Zn Z X Wa 0.88kg 65mm 0mm 5mm 111 Wb 4.35kg 150mm 0mm 42.5mm Y 210 Y Wc 0.795kg 150mm 111mm 42.5mm Wd 1.5kg 150mm 210mm 42.5mm n = a, b, c, d 3 Composite center of gravity calculation m3 = mn = 0.88 + 4.35 + 0.795 + 1.5 = 7.525kg 1 m3 X = x (mn x xn) 1 7.525 = (0.88 x 65 + 4.35 x 150 + 0.795 x 150 + 1.5 x 150) = 140.1mm 1 m3 Y = x (mn x yn) 1 7.525
VJ324M Release valve VJ114 B Manual override (Simply turn the locking type override.)
Manual override (Non-locking) Bracket B (Standard accessory) (Mounting hole) Bracket B (Standard accessory) (Mounting hole) Supply valve Release valve Release valve Supply valve N.O.
B Sets alarm which is selected for contact output 3. [-] is displayed when the setting of the output signal of contact output3 is not selected alarm signal. Contact output signal 3 ---(AL.01) selected alarm 2.4 Setting and checking HRS100/150 Series 2-4 HRX-OM-S010 Chapter 2 Contact input/output communication 2.4.2 Setting and checking Communication mode Setting and checking 1.
6 6.5 10.5 13.5 16.5 19.5 B 12.5 15.5 18.5 21.5 A 29 29.5 33 24 28.5 29 B 6.5 7 11 14 17 20 A 26 26.5 30 21 25.5 26 B 3.5 4 8 11 14 17 A 19.5 24 24.5 B 9.5 12.5 15.5 A 31.5 22.5 27 27.5 B 9.5 12.5 15.5 18.5 A 35.5 26.5 31 31.5 B 13.5 16.5 19.5 22.5 MK220 MK225 MK232 MK240 MK250 MK263 Auto Switch Mounting Bracket Part No.
Description Body cover Bearing cap Damper End cover A End cover B Photomicrosensor Sensor plate Connector A Connector B No.
Inrush Current Flow Time (Reference) 200 V Current 100 V 0 5 15 10 20 25 30 Time [Second] 2 Mounting position of the heater Heater symbol XL-25-2 XL-40-2 XL-50-2 XL-63-2 XL-80-2 H4 (100C) (a) (a) (b), (c) (a), (b), (c) H5 (120C) (a) (b), (c) (b), (c) (a), (b), (c) (b), (c) (b) (a) (c) Heater (Option) 17 Aluminum High Vacuum Angle Valve: With Heat-resistant Auto Switch XLm Series Made to
PF2A703H--28 PF2A703H--68 PF2A706H--28 PF2A706H--68 PF2A703H--29 PF2A703H--69 PF2A706H--29 PF2A706H--69 3000 150 3000 150 6000 300 6000 300 PF2A712H--28 PF2A712H--68 PF2A712H--29 PF2A712H--69 12000 600 12000 600 13
mm x 150 mm, capacitance: 20 pF) as defined in the U.S.
Change of fluid passage Flow Characteristics Flow characteristics 1 2 (P A) C [dm 3/(sbar)] 27 38 Port size 2 3 (A R) C [dm 3/(sbar)] 27 40 2 1 (A P) C [dm 3/(sbar)] 25 40 3 2 (R A) C [dm 3/(sbar)] 26 38 b 0.38 0.30 b 0.37 0.32 b 0.36 0.22 b 0.37 0.20 Cv 7.0 9.8 Cv 7.4 9.8 Cv 7.3 9.8 Cv 6.8 9.6 1/2 3/4 N.C. N.O.