/ED5 -97No.EX-OMU0028-D EX600-ED4/ED5-2 -98No.EX-OMU0028-D EX600-ED4/ED5-3 -99No.EX-OMU0028-D EX600-EU1 EX600-EU1-2 -100No.EX-OMU0028-D EX600-EU1-3 -101No.EX-OMU0028-D Accessories -102No.EX-OMU0028-D 1.
R. 3 port only Force Component Parts POM PBT Material Note No.
19 7 JCQ Series Auto Switch Mounting Auto Switch Proper Mounting Position (Detection at stroke end) and Mounting Height D-M9m D-M9mW D-M9mA D-M9mV D-M9mWV D-M9mAV U A B [mm] Auto Switch Proper Mounting Position [mm] Auto Switch Mounting Height D-M9m D-M9mV D-M9mW D-M9mWV D-M9mA D-M9mAV A B 12 5 2.5 16 5.5 3 20 6 6 25 6 7.5 32 8 8 40 11 9 50 11.5 11 63 13.5 13.5 80 16.5 18 100 19.5 21 Auto
D-A80 =U B + First-stage stroke =U B A D-A7H D-A80H D-F7 D-J79 D-F7W D-J79W D-F7F D-Y7NTL D-F7BAL B + First-stage stroke =U SMC =U B A D-A73C D-A80C D-J79C B + First-stage stroke =U =U B A D-A79W D-F7WV D-F7V D-F7BAVL B + First-stage stroke =U SMC =U B A 11 3 Position Cylinder Series RZQ D-A9 D-F9 D-F9W D-A9V D-F9V D-F9WV D-F9BAL B =U =U A B + First-stage stroke 50 or larger bore size D-P5DW
(Not mountable after the time of shipment) RHC MK(2) Auto Switch Mounting Height RS Q G D-B5/B64 D-B59W D-G5 D-K59 D-G5NTL D-G5W D-K59W D-G59F D-F5 D-J5 D-F5W D-J59W D-F59F D-F5NTL Auto switch model D-Z7/Z80 D-Y59 D-Y7P D-Y7W D-Y69 D-Y7PV D-Y7lWV D-A44 D-A44C D-A3 D-G39 D-K39 D-A3C D-G39C D-K39C D-A5 D-A6 D-A59W RS H A RZQ Bore size (mm) Hs Ht Hs Hs Hs Ht Hs Hs Ht Hs Ht Hs Hw Hs Hw MI W S
(Not mountable after the time of shipment) Auto Switch Mounting Height D-B5/B64 D-B59W D-G5 D-K59 D-G5NTL D-G5W D-K59W D-G59F D-F5 D-J5 D-F5W D-J59W D-F59F D-F5NTL Auto switch model D-Z7/Z80 D-Y59 D-Y7P D-Y7W D-A3C D-G39C D-K39C D-A44 D-A44C D-A3 D-G39 D-K39 D-Y69 D-Y7PV D-Y7WV D-A5 D-A6 D-A59W Bore size (mm) Hs Hs Ht Hs Ht Hs Ht Hs Hs Ht Hs Hw Hs Hw Hs 40 38 40 31 38.5 31 30.5 30 72.5 73
(A) 2 4.5(0.25) 9.0(0.5) Refer to Best Pneumatics Vol. 4 for further details. 3 (R) 1 (P) 3 (R) 1 (P) Specifications
0 P1(11) port u R(4) Exhaust port r !5 o !7 A(2) port P2(12) port !4 !3 w !2 !
MY CY Proper Auto Switch Mounting Position MG A B Auto switch model CX D-Y5 D-Y6 D-Y7P D-Y7PV D-Y5 D-Y6 D-Y7P D-Y7PV D-Z7 D-Z80 D-Y7W D-Y7WV D-Y7W D-Y7WV D-Z7 D-Z80 DCylinder model CYP15 24.5 93.5 -X CYP32 33 122 20Data Mounting of Auto Switch When mounting auto switches, they should be inserted into the cylinder's switch groove from the direction shown in the drawing on the right.
MY CY Proper Auto Switch Mounting Position MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A B Auto switch model CX D-Y5 D-Y6 D-Y7P D-Y7PV D-Y5 D-Y6 D-Y7P D-Y7PV D-Z7 D-Z80 D-Y7W D-Y7WV D-Y7W D-Y7WV D-Z7 D-Z80 DCylinder model CYP15 93.5 24.5 -X CYP32 122 33 20Data
(different sides or same side) 15 25 1 pc. 10 Auto Switches / Proper Mounting Position and Height for Stroke End Detection Reed switch Solid state switch A B Hs A B Hs Ht Ht Auto switch mounting position Auto switch mounting height D-A5 D-A6 D-A59W D-F5, D-J5 D-F5W D-J59W D-F5BAL D-F5 D-J5 D-A5, D-A6 D-A59W D-F5NTL D-F5W, D-J59W D-F5BAL, D-F5NTL Bore size (mm) Bore size (mm) Hs Ht Ht Hs B
L R S Piping port position Nil Operating direction Left Right L R S a b h g d c f e Note) Plugs are installed in ports other than those indicated for the model.
L R S Piping port position Nil Operating direction Left Right L R S a b h g d c f e Note) Plugs are installed in ports other than those indicated for the model.
L R S Piping port position Nil Operating direction Left Right L R S a b h g d c f e Note) Plugs are installed in ports other than those indicated for the model.
0x0013 (19) 0 R Product ID Example: ISE20C-L 0x0014 (20) 0 R Product text Pressure sensor Initial value is indicated as 8-digit. 16 octets fixed character string 0x0015 (21) 0 R Serial number Example: "x" (22) 0 R Hardware version HW-Vx.y x: Large revision number y: Small revision number 0x0016 (23) 0 R Software version FW-Vx.y x: Large revision number y: Small revision number 0x0017 (36
CH kPa 4 3 2 1 SW t e AV y D-IN RUN UP SET P-ON AU DOWN STOP READ r u AF i AR o Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com t y u i o IR !
0 q CONTROLLER PRESSURE OUT w Position Detection Switch Flow Sensor Pressure Control Pressure Sensor e w r RUN 4 3 2 1 CH kPa 4 3 2 1 SW t e y D-IN RUN UP SET P-ON DOWN STOP READ r u i o t y u i o !
, A80, D-A7lH, A80H D-A73C, A80C 54 12 Reed switch D-A79W D-J79, J79W 53 49 11 11 12 2 wire 3 wire 56 Solid state switch D-F7 4 wire 56 14 Write "L" at the end of the part number for 3 meters of lead wire.
r r r q w e OUT side passage IN side passage y u t OUT IN i o Basic type (Knob): IR30l0-A e e r q r w e OUT side passage IN side passage t u OUT IN o i Basic type (Knob): IR30l1 2-A e e r q r w e OUT side passage IN side passage t u OUT IN o i 800 Precision Regulator IR1000-A/2000-A/3000-A Series Dimensions Basic type (Knob): IR10l0-01l-A 10.5 42 ARJ 1.6 Bracket AR425 to 935 Mounting hole