SMC Corporation of America
Elite Part Number Search
Search Results "ISE20CH-R-P-N02-WY"

Rated Pressure Range: -100 to 100 kPa, Piping: NPT1/4, M5 Female, Rear Ported, Input/Output: NPN Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: -, Option 2: -, Option 3: -, X Options: -

Rated Pressure Range: 1 to -101 kPa, Piping: NPT1/4, M5 Female, Rear Ported, Input/Output: NPN Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: -, Option 2: -, Option 3: -, X Options: -

Body Size: IR2000, Type of Setting: 0 [Basic (Handle)], Set Pressure: 2 [0.005~0.8MPa (IR1000/2000) or 0.01~0.8MPa (IR3000)], Thread: NPT, Port Size: 02 [1/4 (IR2000/3000)], Accessory: None, Temperature Environments: Standard, Suffix: Opposite Side Mounting of Pressure Gauge, Bracket, Name Plate, Made to Order: -

Body Size: IR3000, Type of Setting: 0 [Basic (Handle)], Set Pressure: 2 [0.005~0.8MPa (IR1000/2000) or 0.01~0.8MPa (IR3000)], Thread: NPT, Port Size: 02 [1/4 (IR2000/3000)], Accessory: None, Temperature Environments: Standard, Suffix: Opposite Side Mounting of Pressure Gauge, Bracket, Name Plate, Made to Order: -

Body Size: IR3000, Type of Setting: 0 [Basic (Handle)], Set Pressure: 1 [0.005~0.4MPa (IR1000/2000) or 0.01~0.4MPa (IR3000)], Thread: NPT, Port Size: 02 [1/4 (IR2000/3000)], Accessory: None, Temperature Environments: Standard, Suffix: Opposite Side Mounting of Pressure Gauge, Bracket, Name Plate, Made to Order: -

Body Size: IR2000, Type of Setting: 0 [Basic (Handle)], Set Pressure: 0 [0.005~0.2MPa (IR1000/2000) or 0.01~0.2MPa (IR3000)], Thread: NPT, Port Size: 02 [1/4 (IR2000/3000)], Accessory: None, Temperature Environments: Standard, Suffix: Opposite Side Mounting of Pressure Gauge, Bracket, Name Plate, Made to Order: -

Body Size: IR2000, Type of Setting: 0 [Basic (Handle)], Set Pressure: 1 [0.005~0.4MPa (IR1000/2000) or 0.01~0.4MPa (IR3000)], Thread: NPT, Port Size: 02 [1/4 (IR2000/3000)], Accessory: None, Temperature Environments: Standard, Suffix: Opposite Side Mounting of Pressure Gauge, Bracket, Name Plate, Made to Order: -

Body Size: IR2000, Type of Setting: 1 [Air Operated (Series IR2000/IR3000 Only)], Set Pressure: 2 [0.005~0.8MPa (IR1000/2000) or 0.01~0.8MPa (IR3000)], Thread: NPT, Port Size: 02 [1/4 (IR2000/3000)], Accessory: None, Temperature Environments: Standard, Suffix: Opposite Side Mounting of Pressure Gauge, Bracket, Name Plate, Made to Order: -

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Nozzle Diameter: 13 (ΓΈ1.3mm), Vacuum Pressure: S (-90 kPa), SUP: N01 (Screw-in NPT 1/8), VAC: N02 (Screw-in NPT 1/4), EXH: N02 (Screw-in NPT 1/4), Accessories: N (w/o Bracket, w/o Silencer)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)