Use this table as a guideline for mounting.
4 (A) 4 1 (P) 3 (R) 5 (R) 1 (P) 3 (R) How to Order Manifold Base 2 position double 2 position double (B) 2 (A) 4 (B) 2 (A) 4 Same manifolds as series SYJ3000 are prepared. 1 (P) 3 (R) 5 (R) 1 (P) 3 (R) SS5YJA3 Fill the same as SS5YJ3 3 position closed center 3 position closed center (B) 2 (A) 4 (B) 2 (A) 4 Instruct by specifying the valves and blanking plate assembly to be mounted on the
U U Side The side connected to the solenoid valve when the product is connected to a manifold. 9 EX## OMS1015-A Assembly Composing the unit as a manifold : If the unit was purchased as a manifold, the work described in this section is not necessary. (1) Connect the unit to the end plate. The Digital unit, Analog unit can be connected in any order.
Perform inspections on a regular basis as necessary, such as at the beginning of an operation, to make sure that the mechanical valve operates properly. Failure to observe this precaution could lead to unsafe operation, such as unintended operation or malfunction.
Since terminal numbers are not indicated on the flat cable, use the triangle mark as a reference when wiring. 8 Cassette Type Manifold Series SZ3000 Manifold Electrical Wiring 60PG Flat cable type (20 pins) Without power supply terminals With power supply terminals Positive common Negative common Common 20 20 20 Pos. pin (common) Pos. pin 19 19 19 SOL.B 18 18 Neg. pin Neg. pin (common)
Auto switch: (for main exhaust valve) Heater: 23 Series XLD, XLDV High Vacuum Angle Valve Dimensions (mm) 1in=25.4mm (b) XLD/Air operated type E C D E Fn (KF flange) Fd (K flange) (a) C E (c) B A G H J K Heater (optional) A (mm) H Fd G 26 41 52 70 83 Fn 40 55 75 87 114 D 1 2 2 3 3 C 48 66 79 100 117 B 123 170 183 217 256 A 50 65 70 88 90 E J 16 20 20 20 20 K 6.5 14 16.5 18.5 26.5 Model XLD
When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8.
If driving a load such as a relay that generates a surge voltage, use a switch with a built-in contact protection circuit or use a contact protection box. 1) For an auto switch without a contact protection circuit, use a contact protection box when the wire length is 50m or longer.
performance is based on data using a charged plate (size: 150 mm x 150 mm, capacitance: 20 pF) as defined in the U.S.
Model Model Note 2) Since vibration may increase with low speed operation, use 2mm/s or more as a guide for speed. LC6C-220AD (Refer to page 309 for details.)
items is handled as a special order product.
Use this as a guideline purpose only for model selection because the value varies depending on the material and/or size of a subject.
Mixed single and double wiring is available as a semi-standard specification.
As a result, it is necessary for the customer to verify conformity to the EMC directive for the machinery and equipment as a whole. w CC-Link direct input type (LECPMJ) is not CE-compliant. [UL-compliant products] When conformity to UL is required, the electric actuator and controller/driver should be used with a UL1310 Class 2 power supply.
(Recommended tightening torque: 20 to 25 Nm) *1 The thread ridge shape is in compliance with G thread standard ISO 228-1, but the other shapes are not in compliance with ISO 16030 or ISO 1179. Use a male thread with a length of 9 or less for connection.
To accomplish this, use a device such as a highly responsive electric control circuit or solenoid valve driven by direct current, and place the solenoid valve as close as possible to the cylinder. 8. Be aware that the stopping accuracy is influenced by changes in the piston speed.
IDG5H (Type A products group) IDG3H (Type A products group) P1 = 0.3 MPa 0 P1 = 0.3 MPa 0 Outlet air atmospheric pressure dew point (C) Outlet air atmospheric pressure dew point (C) P1 = 0.5 MPa P1 = 0.5 MPa P1 = 0.7 MPa 10 10 P1 = 0.7 MPa 20 20 30 30 40 40 0 40 30 20 10 20 40 60 80 0 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650)
1(0) 1(0) 2(0) 7 B 0(0) 0(0) 0.5(0) 5.5 A 6(4) 6(4) 7(5) 12 B A B 1.5(0) 1.5(0) B 0(0) 0(0) 1(0) 6 B 5(3) 5(3) 6(4) 11 A 7(5) 7(5) 8(6) 13 A B 6(4) 6(4) 7(5) 12 A 4(2) 4(2) 5(3) 10 B 3(1) 3(1) 4(2) 9 A 0.5(0) 0.5(0) 1.5(0) 6.5 Hs 22.5 25 28.5 32.5 Hs 25 27.5 31 35 Hs 60 62.5 66 70 Hs 69.5 72 75.5 79.5 Bore (mm) 20 25 32 40 4.5(2.5) 3.5(1.5) 2.5(0.5) 4.5(2.5) 3.5(1.5) 2.5(0.5) MGF 2.5(0.5)
Do not apply a tensile force to a cord. To connect the switch body and the contact protection box, connect the lead wire of the contact protection box on the side marked with SWITCH and the lead wire from the switch body. Connect the switch body and the contact protection box with a lead wire of 1 m or shorter and arrange them as close as possible.