HRS090 AND LARGER CAPACITIES. HRLE090 CH1 Heat Exchanger Assy. 4.50000 lb. O88.
HRS090 AND LARGER CAPACITIES. Dual Channel Chiller for Lasers. 260.00000 lb. O88.
HRS090 AND LARGER CAPACITIES. Dual Channel Chiller for Lasers. 260.00000 lb. O88.
HRS090 AND LARGER CAPACITIES. Dual Channel Chiller for Lasers. 315.00000 lb. O88.
A large digital display provides a clear view of the current and set values.
A large digital display provides a clear view of the current and set values.
A large digital display provides a clear view of the current and set values.
A large digital display provides a clear view of the current and set values.
Types: Dryers, Method: [Freezing] Refrigerating type (air-cooling specification), Shape: Standard, Outlet Flow Rate(l/min): 1,220 / 1,320, Outlet Open Air Pressure Dew-Point(°C): 10, Exit Flow Rate Class(l/min): Up to 2000, Supply Side Connection Type: [Rc (R)] Rc, Inlet Air Temperature(°C): 35, Inlet Air Pressure(MPa): 0.7, Supply Side Plumbing Thread Nominal: 3/4, Control Side Connection
Size: 37 [6.1m³/min (ANR), 215.4.scfm], Voltage: 20 [200VAC (50Hz), 200/220VAC (60Hz), Single Phase], Option 1: Motor Type Auto Drain, Option 2: -
Size: 6 [0.82m³/min (ANR), 28.96scfm], Voltage: 20 [200VAC (50Hz), 200/220VAC (60Hz), Single Phase], Option 1: M (Motor Type Auto Drain)
Size: 8 [1.32m³/min (ANR), 46.62scfm], Voltage: 20 [200VAC (50Hz), 200/220VAC (60Hz), Single Phase], Option 1: M (Motor Type Auto Drain)
Size: 6 [0.82m³/min (ANR), 28.96scfm], Voltage: 20 [200VAC (50Hz), 200/220VAC (60Hz), Single Phase], Option 1: Motor Type Auto Drain, Option 2: -
A large digital display provides a clear view of the current and set values.
A large digital display provides a clear view of the current and set values.
A large digital display provides a clear view of the current and set values.
Cooling Capacity: 060 (Cooling Capacity: 4900/5900, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: M [Applicable to DI Water (Deionized Water) Piping]
Rated Flow Range: 12 (120 to 12000 l/min), Thread Type: Rc, Port Size: 20 (2), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: M (SI Unit Only)
Cooling Capacity: 030 [2500/3000, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: M (Applicabe to DI Water Piping)
Cooling Capacity: 012 [1000/1200, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: M (Applicabe to DI Water Piping)