(Refer to pages 15-6-3 to 15-6-5 for details.) Note 2) Brass parts are all electroless nickel plated.

23.1 16 27.1 12.7 20.4 14.3 31.1 36.1 27.5 3.2 9.3 1/4" 12 12 32.1 13.5 R 1/8 AS221FG-01-04 AS221FG-N01-01 12.7 20.4 27.5 4 9.3 1/8" 16 20.4 27.5 17 9.3 12.7 AS221FG-01-06 AS221FG-N01-03 13.5 20.4 13.4 27.5 6 11.6 5/32" 14.2 13.4 27.1 30.2 35.2 12 32.1 NPT 1/8 R 1/8 17 AS221FG-01-08 AS221FG-N01-05 23.1 12.7 30.2 19 18.5 35.2 25.3 32.1 30.2 32.4 8 15.2 3/16" 11.4 27.1 16.5 14.2 AS221FG-01

PFM7-C4/C6/C8/N7--X693 PFM7S-C4/C6/C8/N7--X693 PFM7-01/02--X693 PFM7S-01/02--X693 -73No.PF-OMJ0006-J PFM7-C4/C6/C8/N7--X694 PFM7S-C4/C6/C8/N7--X694 PFM7-01/02--X694 PFM7S-01/02--X694 -74No.PF-OMJ0006-J For a mixture of Argon (Ar) and carbon dioxide (CO2) The mixture ratio can be selected from Ar : CO2 = 92 : 8, 90 : 10, 80 : 20, 70 : 30 or 60 : 40.

Dimensions (mm) Weight (g) Effective area (mm2) Recommended flow (m3/min (ANR)) Port size R Model A B C 1 8 1 4 3 8 1 2 3 4 1 1 1 14 64 22 18 ANA1-01 ANA1-02 ANA1-03 ANA1-04 ANA1-06 ANA1-10 ANA1-12 ANA1-14 ANA1-20 4 37 16 10 15 35 60 90 160 280 450 610 0.8 or less 1.2 or less 2.7 or less 4.5 or less 7.0 or less 12.0 or less 20.0 or less 32.0 or less 45.0 or less 84 25 21 98 30 24 111 46

For precise pressure detection, allow the product to warm up for 10 to 15 minutes. Check if the product satisfies the specified accuracy 10 minutes after supplying power. Warming up inadequate Product failure Replace the product. -101No.PS-OMW0012-C Problem No.

If the installation is using accurate control, wait until the product has warmed up (approximately 10 to 15 minutes).

DC12~24V DC12~24V DC(+) DC(-) 8 / / 9 () 10 / 5m / 11 20~30 20 "-M" (kPaMPa) SI kPa,MPa ( ) "-M" 12 13 -33No.PS-OMH0005CN-D No. 14 15 () () ( ) ( ) / 16 ON ON OFF PSE530 PSE530 OFF -34No.PS-OMH0005CN-D OUT1 OUT2 80mA 5 F.S.(2.5F.S.) 2 -35No.PS-OMH0005CN-D PSE20 1 01 MPa 0-101 kPa 0101 kPa -101101 kPa -0.11 MPa 10-101 kPa -10101 kPa -101101 kPa 0.1 kPa 0.1 kPa 0.1 kPa

class H 4 Direct Operated 2 Port for Oil Series VCL How to Order Manifolds How to Order Manifold Assemblies (Example) VV2C L 2 02 01 Enter the valve and option models to be mounted under the manifold base part number.

High flow rate: Cv factor 0.16 to 2.1 Smaller size: Single valve volume reduced by 15% (Class 3) Manifold length reduced by 18% (Class 3: 5 stations) (SMC comparison) Clip type Quick change coils Clip design makes coil replacement easy Flame resistance Coil size and weight reduced Conforms to UL94 V-0 New compact coil reduces the overall size and weight of the valve Volume 15% Weight 20%

Option Blank plate AXT512-9A Model Effective area (WitH sub-plate) (mm 2) (Nl/min) Response time (2) (sec) Weight (3) (kg) 0.040 or less 0.020 or less 0.05 or less 0.05 or less 0.06 or less Max. operating rate (1) No. of positions Model 3 8 (cycle/sec) 15 15 10 10 8 VS7-8-FG-S--Q VS7-8-FG-D--Q VS7-8-FHG-D--Q VS7-8-FJG-D--Q VS7-8-FPG-D--Q 58 (3140.80) 58 (3140.80) 58 (3140.80) 58 (3140.80)

mm 15 mm mm RoHS Pressure switch with spacer Pressure switch with piping adapter Set Pressure Range Specifications Electrical Circuit Up to 100 V AC/DC ON pressure OFF pressure Model IS10-01 Air/Inert gas 0.5 Fluid Hysteresis Reed switch Operating pressure (MPa) Proof pressure 1.0 MPa 0.4 Max. operating pressure 0.7 MPa 0.1 to 0.4 MPa Option: 0.1 to 0.6 MPa 0.3 Set pressure range 5 to 60C

View A PFA3-B DIN rail type Sensor Blue Brown Black Analog output 1 2 3 4 3 x 7.2 (= 21.6) 8-M3 36 15 6.4 2 3.4 5 6 7 8 OUT1 N.C. Load Load 2 1 3 4 6.5 12 to 24VDC + 26 SMC FLOW SWITCH PFA312-(-M) 35.5 30 15.2 56 (4.5) 44 UNIT RESET SET Sensor Blue Brown Black Analog output 1 2 3 4 5 6 7 8 5 6 7 8 29 OUT1 N.C.

High flow rate: Cv factor 0.16 to 2.1 Smaller size: Single valve volume reduced by 15% (Class 3) Manifold length reduced by 18% (Class 3: 5 stations) (P/A comparison) Clip type Quick change coils Clip design makes coil replacement easy Flame resistance Coil size and weight reduced Conforms to UL94 V-0 New compact coil reduces the overall size and weight of the valve Volume 15% Weight 20%

class H 4 Direct Operated 2 Port for Oil Series VCL How to Order Manifolds How to Order Manifold Assemblies (Example) VV2C L 2 02 01 Enter the valve and option models to be mounted under the manifold base part number.

For precise flow detection, allow the product to warm up for 10 to 15 minutes. Check if the product satisfies the specified accuracy 10 minutes after supplying power. Warming up inadequate Product failure Replace the product. -94No.PF-OMA1011-A Problem No.

0 0 0 5 10 15 20 25 0.2 0.3 0.4 0.5 [MPa] [L/min (AMR) ] Pmax Qmax 10 Pmax 2 (P1 Q1 ) 3 Qmax 0 37 - No.ZQ-OM01401-B 11.2 () ZQ000A 11.3 -100 -80 [kPa] -60 -40 -20 0 (V 6 ) 0 5 10 15 20 [L/min (AMR) ] ZQA (PD)() ZQ000A (PD) 100 80 [L/min(ANR)] 70 [L/min(ANR)] 0.5MPa 0.5MPa 80 60 0.4MPa 50 0.35MPa 0.3MPa 60 0.3MPa 40 40 30 20 20 10 0 0 0 1 2 3 4 5 0 1 2 3 4 5 [] [] ZQA (PD)()

(Ex.) 1. 2. 3. 4. 14-2 IDU8E/11E/15E1-23-V IDF-S0198 1.6MPa AC230V10% (50Hz) ON 0.5sec OFF 30 IDU Series 141 IDX-OM-W023 14 V 14-3 1) 2) 3) 4) ON OFF 4 6 2 3 8 4 2 1 10 0.5 5 0.5 ON:SEC OFF:MIN 14-4 1-1 IDU Series 142 IDX-OM-W023 15 15 15-1 / IDU Series 15-1 A2020/1 B2021/5 Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Tel: +81 3 5207

Maintenance detection signal ON OFF Output Requirement for maintenance detected ON OFF Input External switch signal 1, 2 455 IZN10 Series Dimensions 06 07 06 07 Energy saving static neutralization nozzle/IZN10-01 High flow rate nozzle/IZN10-02 20 Note 1) (110) 16 100 5 5 46 A 3.4 18.5 11 6 5 6 A 8 7 (Tap for ground wiring) M3 x 0.5 depth 4 40 25 12 A 93.6 A-A (mm) A Model 01 02 01 02 IZN1006