Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 12, Stroke: 30mm, Action: Double Acting, Rod End Thread: Rod End Male Thread, Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 10, Stroke: 6mm, Action: Single Acting Spring Return, Rod End Thread: Rod End Male Thread, Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 6, Stroke: 8mm, Action: Single Acting Spring Return, Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in Magnet, Mounting Direction: Axial Mounting, Bore Size: 12, Stroke: 10mm, Action: Single Acting Spring Return, Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 6, Stroke: 20mm, Action: Double Acting, Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 8, Stroke: 30mm, Action: Double Acting, Rod End Thread: Rod End Male Thread, Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in Magnet, Mounting Direction: Axial Mounting, Bore Size: 16, Stroke: 20mm, Action: Double Acting, Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 20, Stroke: 15mm, Action: Double Acting, Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in Magnet, Mounting Direction: Axial Mounting, Bore Size: 16, Stroke: 15mm, Action: Double Acting, Rod End Thread: Rod End Male Thread, Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in Magnet, Mounting Direction: Axial Mounting, Bore Size: 16, Stroke: 20mm, Action: Double Acting, Rod End Thread: Rod End Male Thread, Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in Magnet, Mounting Direction: Axial Mounting, Bore Size: 16, Stroke: 25mm, Action: Double Acting, Rod End Thread: Rod End Male Thread, Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in Magnet, Mounting Direction: Axial Mounting, Bore Size: 16, Stroke: 35mm, Action: Double Acting, Rod End Thread: Rod End Male Thread, Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 6, Stroke: 10mm, Action: Double Acting, Rod End Thread: Rod End Male Thread, Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 8, Stroke: 4mm, Action: Double Acting, Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 6, Stroke: 4mm, Action: Single Acting Spring Return, Rod End Thread: Rod End Male Thread, Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 6, Stroke: 4mm, Action: Double Acting, Rod End Thread: Rod End Male Thread, Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 12, Stroke: 35mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 12, Stroke: 40mm, Action: D (Double Acting), Rod End Thread: M (Rod End Male Thread), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: L (3m)
800 400 30 Capacity of converter (cm3) 300 CC CC 25 600 500 400 100 CRA1H100-180 200 20 CRA1H100-90 300 300 100 CRA1H80-180 200 200 150 CRA1H80-90 50 CRA1H63-180 100 100 80 CRA1H63-90 CRA1H50-180 60 50 40 50 CRA1H50-90 30 Selected model of rotary actuator 160 100 63 40 20 100 200 300 400 500 600 700 800 Nominal size of converter (mm) Cylinder stroke (mm) How to read the graph (ex: when using
Stations n L1 L2 3 68 59 6 116 107 8 148 139 10 180 171 4 84 75 5 100 91 7 132 123 9 164 155 11 196 187 12 212 203 13 228 219 14 244 235 15 260 251 16 276 267 17 292 283 18 308 299 19 324 315 2 stations 52 43 20 stations 340 331 532 Manifold specifications 10-SYJ5000 Type 42: Side ported / 10-SS5YJ5-42Stations -01, C6 N7 [ ]: AC Grommet (G) 01 C6 N7 (With built-in One-touch fitting) Air