Printed in Japan. 1st printing May, 2000 D-SMC.L.A. P-80 (D)
SD0 SDA1 SDA2 Serial kit without SI unit Serial kit for Remote I/O 1 to 8 stations (16 stations) FD0 FD1 FD2 FD3 D-sub connector kit (25P) without cable Serial unit: EX126 D-sub connector kit (25P) with 1.5 m cable 1 to 12 stations (24 stations) Serial kit for DeviceNet/PROFIBUS-DP/CC-LINK D-sub connector kit (25P) with 3.0 m cable P SDVB Serial kit for CC-LINK 1 to 8 stations (16 stations
Thermo-chiller with exhaust from the side: Body space: W15.7in (400 mm) x D 33.3 in (845 mm) Ventilation space: 3.9 in (100 mm) 15.0 (380) HRW008-H : Body space: W15.0 in (380 mm) x D 26.2 in (665 mm) Ventilation space: 0 15.7 (400) 3.9 (100) 33.3 (845) 26.2 (665) 10.0 ft2 (0.93 m2) 5.5 ft2 (0.51m2) 98 High Performance Easy Maintenance Temperature stability: 0.54F (when a load is stable)
CE2 ML2B ML1C Mounting Position (Stroke End)/Reed Switch Mounting Position (Stroke End)/Solid State Switch D-E73A (L), D-E76A (L), D-E80A (L) D-M5B (L), D-M5N (L), D-M5P (L) D-M5BW (L), D-M5NW (L), D-M5PW (L) D-M5NTL, D-M5PTL REA REC RHC MTS CC Lead wire clamp/Lead wire cap (option) Series Lead wire clamp Lead wire cap ML1C LC-01 LP-01 Unit: mm Lead wire clamp/Lead wire cap (option) 25 32
DC specifications of type D and DO is only available with 12 and 24 VDC.
/M5W/M5TL D-E7A/E80A 25 6 4 32 6 4 D-M5, D-M5W, D-M5TL D-E7A, D-E80A D10 15 5 10 1 pc. 2 pcs.
/M5W/M5TL D-E7A/E80A 25 6 4 32 6 4 D-M5, D-M5W, D-M5TL D-E7A, D-E80A D10 15 5 10 1 pc. 2 pcs.
Range (mm) No. of auto switches mounted Applicable auto switch Bore size (mm) 25 6 4 D-M5, D-M5W, D-M5T D-E7A, D-E80A Auto switch model 40 6 4 D-M5, M5W, M5T D-E7A, E80A 32 6 4 10 15 5 10 1 pc. 2 pcs.
type D-Z7 type Note 1) Note 1) D-Z8 type D-A9 type D-F9 type D-Y6 type D-Y7 type Note 1) Vertical outlet types cannot be mounted.
/M5W/M5TL D-E7A/E80A D-M5, D-M5W, D-M5TL D-E7A, D-E80A D10 15 5 10 1 pc. 2 pcs.
D-A5/A6, D-A59W Tie rod mounting D-G3/K3 Band mounting Solid state swich D-F5/J5, D-F5NT, D-F5W/J59W, D-F5BA, D-F5F Tie rod mounting 1.10-1 Air Cylinder/Standard Series CS1 Lube, Non-lube: 125, 140, 160, 180, 200, 250, 300 Air-hydro: 125, 140, 160 How to Order CS1 L 300 160 JR Rod boot/Cushion Rod boot Mounting J K N R H Nylon tarpaulin Heat resistant tarpaulin No cushion With cushion on
VH600 VR Option VH300 VH410 VH VH300/400 Bottom ported VH210 VHS VH200/300/400 Panel mounted All models applicable Different P port location (On handle side) Note that 1(P) port of VH600 is located on handle side as standard.
D-A9/M9/M9W/M9AL auto switches are shipped together (not assembled).
VH600 VR Option VH300 VH410 VH VH300/400 Bottom ported VH210 VHS VH200/300/400 Panel mounted All models applicable Different P port location (On handle side) Note that 1(P) port of VH600 is located on handle side as standard.
) L6 L8 Note 4) A2 M L7 L4 A1 Note 4) Weight (g) Note 5) Note 1) d D3 MAX.
Note3) L6 L8 Note 4) A2 M L7 L4 A1 Note 4) Weight (g) Note 5) Note 1) d D3 MAX.
(example: If the flow switch with output impedance of 1 k is connected to the A/D converter to detect the analogue output of 5 V, the detected voltage by the A/D converter becomes 5(V) x1(M)/(1(k) + 1(M)) 4.995(V), and there is an error of approximate 0.005 V).
Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-12 Connection of RS-232C 3.3 Installation HRR Series 3-20 HRX-OM-X071 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly.
H5 Initial power / 100 VAC 200/40 400/70 400/80 600/130 800/180 Power 200 VAC 800/40 1600/80 1600/80 2400/130 3200/180 consumption (W) Note 1) Initial power and power consumption are nominal values. Note 2) Heaters are not available for size 16.
Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Fig. 3-13 Connection of RS-232C HRS Series 3.3 Installation 3-25 HRX-OM-W032 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly. Incorrect piping might cause leakage of supplied or drained fluid and wet surrounding area and facility.