SMC Corporation of America
Elite Part Number Search
Search Results "CHSDCB80TN-800-A"

D A [mm] Rubber Stopper A Model A B C D E MXQ6(A) 41.5 27 22 25 20 MXQ8(A, C) MXQ6B 41.5 27 21 25 19 MXQ12(A, C) MXQ8B 46.5 28 21 27 20 MXQ16(A) MXQ12B 51.5 30 21 28 20 MXQ20(A) MXQ16B 58.5 32 22 31 21 MXQ25(A) MXQ20B 65.5 34 22 33 21 Cap bracket RJ-X2300 A cap bracket is mounted to lengthen the A dimension.

B A B A B A B A A A PWR 93.5 COM (35) 64.4 43.2 66 75 (40) series EX500 2 9 SI unit 4 x M4 mounting hole 8 7 6 5 4 3 2 1 n D side Stations U side C8 [3(R) EXH port] C8: 8 One-touch fitting M12 8-pin socket DIN rail clamp screw R R 0 62.5 3 3 60 1 X X 40.5 B B B B B B B B 12 12 22.2 P P 25 1 1 A A A A A A A A 18.5 7.5 9.5 (12) (7.5) M12 8-pin plug C8 [1(P) SUP port] C8: 8 One-touch fitting

(L4) (L3) (5.25) L2 L1 Top entry port Not machined 27 P = 10.5 55 29 13 63.5 <67.5> 13 (12) Indicator light Manual override 4.5 66 (35) (5.5) A A A B A B A B A B A 93.5 <100.4> 40 4 x M5 mounting hole 67 66 2 Stations 8 7 6 5 4 3 2 1 D side U side n DIN rail clamp screw C8 [3(R) EXH port] C8: 8 One-touch fitting R R 61.5 G 1/2 18.7 7.7 40.7 25 9.3 B B B B B B B B X X P P A A A A A A A A

Low Speed Auto switch model Bore size (mm) 20 25 32 40 50 63 80 100 D-M9(V) D-M9W(V) D-A9(V) MQ BMA3-020 (A set of a, b, c, d) BMA3-025 (A set of a, b, c, d) BMA3-032 (A set of a, b, c, d) BMA3-040 (A set of a, b, c, d) BMA3-050 (A set of a, b, c, d) BMA3-063 (A set of a, b, c, d) RHC D-M9A(V) Note 2) BMA3-020S (A set of b, c, d, e) BMA3-025S (A set of b, c, d, e) BMA3-032S (A set of b,

A A A A A P R 15.5 8.5 R P 31.5 B B B B B B 65.4 4-Rc(PT)1/8 (P, R port) Manual override 2n-M3 X 0.5 (A, B port) Depress and turn to operate and lock override.

For a facility with a large installation area that can vent the air naturally: Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2. For a facility with a small installation area that cannot vent the air naturally: Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level. 3.

Auto switch model Bore size (mm) 20 25 32 40 50 63 80 100 D-M9(V) D-M9W(V) D-A9(V) BMA3-020 (A set of a, b, c, d) BMA3-025 (A set of a, b, c, d) BMA3-032 (A set of a, b, c, d) BMA3-040 (A set of a, b, c, d) BMA3-050 (A set of a, b, c, d) BMA3-063 (A set of a, b, c, d) D-M9A(V) Note 2) BMA3-020S (A set of b, c, d, e) BMA3-025S (A set of b, c, d, e) BMA3-032S (A set of b, c, d, e) BMA3-040S

For a facility with a large installation area that can vent the air naturally: Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2. For a facility with a small installation area that can not vent the air naturally: Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level. 3.

B A HS 056 HS B A B A 075, 106 HS B A B A 150, 200, 250 Note 1) Figures in the table below are references for auto switch mounting positions in the stroke end detection.

For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level. 3.

Type S31 Manifold: Side Ported 91.7 [96.1] Approx. 300 (Lead wire length) SS5YJ3-S31Stations -M3 L1 L2 3.5 2-3.5 (For mounting) Manual override M5 x 0.8 (P, R port) 5.2 29.2 7.5 52.2 [54.4] 51.4 [53.6] 17.3 30 3 91.7 [96.1] 78.8 [83.2] 78.8 [83.2] 13.5 A A A A A B B B B B P R P R P R 29.2 P R 30 17.3 25 7.5 12 25 51.4 [53.6] 52.2 [54.4] 13.5 B B B B B A A A A A 3 5.2 2-3.5 (For mounting)

, HNBR 9 Body Aluminum die-casted 799 IR1000-A/2000-A/3000-A Series Construction Basic type (Knob): IR10l0-A r r r r q w e OUT side passage IN side passage y u t OUT IN i o Basic type (Knob): IR30l0-A e e r q r w e OUT side passage IN side passage t u OUT IN o i Basic type (Knob): IR30l1 2-A e e r q r w e OUT side passage IN side passage t u OUT IN o i 800 Precision Regulator IR1000-A/2000

Type S31 Manifold: Side Ported 91.7 [96.1] Approx. 300 (Lead wire length) SS5YJ3-S31Stations -M3 L1 L2 3.5 2-3.5 (For mounting) Manual override M5 x 0.8 (P, R port) 5.2 29.2 7.5 52.2 [54.4] 51.4 [53.6] 17.3 30 3 91.7 [96.1] 78.8 [83.2] 78.8 [83.2] 13.5 A A A A A B B B B B P R P R P R 29.2 P R 30 17.3 25 7.5 12 25 51.4 [53.6] 52.2 [54.4] 13.5 B B B B B A A A A A 3 5.2 2-3.5 (For mounting)

If driving a load such as a relay that generates a surge voltage, use a switch with a built-in contact protection circuit or use a contact protection box.

1A VXN Z 1 2 A A Enter standard product number.

With functions narrowed down, 2 independent temperature control systems have been achieved with only a single compressor , a single pump , and a single tank .

Never mount a product in a location that will be used as a foothold. The product may be damaged if excessive force is applied by stepping or climbing onto it. Do not use this cylinder as a stopper. Minimum adjusting stroke necessary for a positioning stop is 5mm. Operate for 5mm or more before a positioning stop. Ex: 1.

Since a large quantity of liquid will be pumped out, use a suitable throttle in the discharge port if problems occur. Note 3) With a low number of operating cycles, even a valve with a small Cv factor can be operated.

Type 20 (5 Port/Body ported) SS5YJ520P 05 A, B port Applicable blanking plate assembly SYJ5000-21-3A A A B A P, R port thread type P port 1/8 B Number of stations A B B 03 3 stations Nil 00F 00N 00T Rc G NPT NPTF : : Applicable connector assembly Refer to page 35. 12 12 stations R port 1/8 Type 41P (5 Port/Base mounted) How to Order SS5YJ541P 05 M5 A A B A, B port M5 x 0.8 A P, R port thread