Function number Function name Default setting Page F 0 (Unit) Units selection [ PA] kPa Page 47 ISA3-F: [ 20] ISA3-G: [ 50] ISA3-H: [ 50] Switch point ISA3-F: [ 3] ISA3-G: [ 20] ISA3-H: [ 20] F 1 (oUt1) OUT1 setting Page 48 Hysteresis Display colour [ SoG] Green when ON, Orange when OFF F 2 (oUt2) (Not available) [. -] Page 50 F 6 ( FSt) Display value compensation [ 0.0] Compensated value
N T, F, N are order made specifications.
+ 100 (n 2) (n = 2, 3, 4, 5) D-G39/K39 D-A3/A44 35 + 30 (n 2) (n = 2, 3, 4, 5) 10 35 100 Note 1) Auto switch mounting Auto switches 2 pcs.
Table 7-1 Quality criteria for clean water (tap water) Standard value Item Unit For circulating fluid For facility water pH (at 25oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Sulfuric acid ion [mg/L] 50 or less 200 or less Standard item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness
override 34.7 [41.7] M5 x 0.8 (A, B port) 2-1.8 (For manifold mounting) (Light/Surge voltage suppressor) 28 [35] + 22.1 54.4 [56.6] 2 13.5 12.6 15 R P R (Bracket) 15 11 10 1.2 (PE port) 22.1 7 7 15 M5 x 0.8 (P, R port) M8 connector (WO): SYJ3120-WO-M3 (-F) L plug connector (L) : SYJ3120-L-M3 (-F) M plug connector (M): SYJ3120-M-M3 (-F) (2) Approx. 300 (Lead wire length) 28 [35] 12.6 32.5
The INPoutput signal is turned on from 100[mm] 1[mm]=99 [mm] Area 2[mm] j Area 1[mm] j 100 b Speed[mm/s] 0 ON AREA Output signal OFF (INPOutput condition) INP Output signal ON In pos[mm] k OFF 101 99 0 10 20 30 40 50 60 70 80 90 100 Stroke [mm] -19- Example of step data input (2) < Positioning operation Ralative > a b c d e f g h i j k No.
The proof pressure is double the operating pressure range. -27No.LV50***-OMQ0004-F Analogue output Flow rate/Analogue output Output A B C Voltage output 1 V 1.1 V 5 V C Current output 4 mA 4.4 mA 20 mA Rated flow rate[L/min] B Model Minimum Maximum A LFE1 0.5 20 Flow rate 0 Minimum rated flow Maximum rated flow LFE2 2.5 100 LFE3 5 200 Out of range -28No.LV50***-OMQ0004-F Dimensions Note)
SET MODE SD SG RD RS-232C COM S.STOP OUT1OUT2OUT3OUT4OUT5 100 to 240 VAC 1 t 1 10 x 106 100 kHz Counting speed f = = = 10 Hz 7 10 4 x 4.5 33.5 104 BCD output connector 2) UP/DOWN input Input wave form conditions: At a maximum of 100 kHz, the UP/DOWN wave form should be as shown below. 125 +12 V 10% UP pulse +12 V 10% DOWN pulse 64 59 3) 15 mA when BCD is output (Refer to page 676.) 668
Example: Full scale reading 100 [kPa] Setpoint for output 50 [kPa] Repeatability 1 [% F .S.] F .S. = 100 [kPa] 0 [kPa] = 100 [kPa] 1 [% F .S.] = 100 [kPa] x 0.01 = 1 [kPa] The deviation from the setpoint is 1 [kPa]. This means that the output can become energized anywhere between 49 to 51 [kPa]. (Refer to the chart below.)
Adsorption surface size 9 SP1130 SP1230 50 x 50 80 110 20 50 65 95 70 5 100 x 100 130 160 20 100 115 145 95 A D Rc 1/8 (Suction port) C F F B D G E E 8 x 5.5 drill Element fixing nut N pcs. 9.5 depth of counter bore 7 (mounting hole) A B C D E F G N Part no.
20 25 30 Operating pressure [MPa] Cylinder output F[N] Load weight [kg] 150 15 Allowable side load on the piston end Unit: N 100 10 Stroke of linear part Size 40 40 50 4 5 5 10 15 20 25 30 40 50 75 100 32 40 32 14 14 13 13 13 12 12 11 10 9 20 25 30 2 2.5 3 23 23 22 21 21 20 19 18 16 15 2) Using the cylinder body installed vertically: To operate the rotary cylinder with the cylinder body
Confirm that the pushing force F [N] does not exceed the allowable pushing force. F Fmax 0 1 2 3 4 5 6 LAT3m-10 Allowable thrust setting value Time while pushing force is applied 4.2 Position 0 20 40 60 80 100 Duty ratio [%] Time From Fig. 5: LAT3m-10, pushing direction away from the connector at pushing position 4 mm, find Fmax = 4.5 As F = 4 Fmax = 4.5, the selected model can be used.
Air Cylinder/Low Friction Series MBlQ 32, 40, 50, 63, 80, 100 How to Order MB L Q F 32 50 Standard MDB L F 32 50 Q A53 With auto switch Built-in magnet Number of auto switches S 3 n 2 1 3 n Mounting Basic/Without bracket Axial foot Front flange Rear flange Single clevis Double clevis Center trunnion B L F G C D T Bore size 32mm 40mm 50mm 63mm 80mm 100mm 32 40 50 63 80 100 Auto switch/Tie
IS400-1 (1S-1) IS400-2 (1S-2) Model Port size B J A C D E F G H I , 1 4 1 2 1 1 AL800-12 to 14-1 AL900-20-1 431 (481) 437 (487) 3 x M5 x 0.8 x depth 6 3 x M5 x 0.8 x depth 6 230 230 ( ): With float switch 117 117 60 60 100 100 2 59 63 166 162 73 73 950
F-CPU Failsafe controller, safe controller F_Destination_Address F-Parameter; PROFIsafe destination address; address of the safe module (see also F-Parameter) F-I/O device Failsafe I/O device, safe input and/or output modules Modules with integrated safety functions, which are approved for safety-related operation. 100 No.EX##-OMY0004 F-Slave Failsafe slave F_Source_Address F-Parameter, PROFIsafe
I 280 F I 300 26 1.6 Width across flats G (E) Width across flats G E 14 E J J 16 22 A A (C) C (C) C 14 2 x H 2 x H Port size Port size 2 x 5.3 2 x 5.3 Mounting hole Mounting hole Width across flats 27 Width across flats 27 14 34 14 34 2 x 5.5 Mounting hole 42 42 B B DIN terminal: D Conduit terminal: T 23 23 (E) G1/2 Cable 6 to 12 K I F I F 34 K D 32 J Width across flats G Width across flats
Cylinder model C D Mounting bolt size RLQB32-20 RLQB32-25 RLQB32-30 RLQB32-40 RLQB32-50 RLQB32-75 RLQB32-100 RLQB40-20 RLQB40-25 RLQB40-30 RLQB40-40 RLQB40-50 RLQB40-75 RLQB40-100 RLQB50-30 RLQB50-40 RLQB50-50 RLQB50-75 RLQB50-100 RLQB63-30 RLQB63-40 RLQB63-50 RLQB63-75 RLQB63-100 90 M5 x 90 L Mounting bolt CLJ2 95 M5 x 95 L 100 M5 x 100 L CLM2 110 M5 x 110 L 8 C Flat washer D 120 M5 x 120
A l a r m S e q u e n c e M O D E < O f f On : Output Off : Not output (Alarm for high and low temperature limit is not detected until the temperature reaches the target temperature after the power is supplied.)
(W) [Current mA] DC 4.5/50 Hz, 4.2/60 Hz 100 VAC: 45/50 Hz, 42/60 Hz 200 VAC: 22.5/50 Hz, 21/60 Hz Note) Inrush Apparent power (VA) [Current mA] AC 3.5/50 Hz, 3/60 Hz 100 VAC: 35/50 Hz, 30/60 Hz 200 VAC: 17.5/50 Hz, 15/60 Hz Refer to pages 3-3-24 to 3-3-27 for manifold use.