SMC Corporation of America
Elite Part Number Search
Search Results "CDM2BZ25-125Z-A93"

Magnet: Built-in, Style: Air Pressure Style, Mounting: Boss-cut Basic, Bore Size: 25mm, Piping: Rc, Stroke: 75mm, Cushion: Rubber Bumper, Stroke Adjust Symbol: None, Rod Boot: None, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 5m, Number: 2 pcs. (Or None in the Case of No Switch), X Options: Low Speed Cylinder

Magnet: Built-in, Style: Air Pressure Style, Mounting: Boss-cut Basic, Bore Size: 25mm, Piping: Rc, Stroke: 150mm, Cushion: Rubber Bumper, Stroke Adjust Symbol: None, Rod Boot: None, Auto Switch: H7BW--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Options: Packing Fluoro

Magnet: Built-in, Style: Air Pressure Style, Mounting: Boss-cut Basic, Bore Size: 25mm, Piping: Rc, Stroke: 100mm, Cushion: Rubber Bumper, Stroke Adjust Symbol: None, Rod Boot: None, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 5m, Number: 2 pcs. (Or None in the Case of No Switch), X Options: Low Speed Cylinder

Magnet: Built-in, Style: Air Pressure Style, Mounting: Boss-cut Basic, Bore Size: 25mm, Piping: Rc, Stroke: 300mm, Cushion: Rubber Bumper, Stroke Adjust Symbol: None, Rod Boot: None, Auto Switch: M9NW--Solid State, 2-color Indication, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc., X Options: w/o Port Orifice

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: Rc, Auto

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushion, Specification: Built-in magnet, Port thread type: Rc, Auto

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: Rc,

Magnet: Built-in Magnet, Mounting: Boss-cut, Basic, Bore Size: 25mm, Port Thread: Rc, Stroke A: 100mm, Rod End Thread A: Male Rod End, Rod Boot A: None, +: None, Stroke B: None, Cushion: Rubber Bumper, Rod End Thread B: Male Rod End, Rod Boot B: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector

Magnet: Built-in Magnet, Mounting: Boss-cut, Basic, Bore Size: 25mm, Port Thread: Rc, Stroke A: 75mm, Rod End Thread A: Male Rod End, Rod Boot A: None, +: None, Stroke B: None, Cushion: Rubber Bumper, Rod End Thread B: Male Rod End, Rod Boot B: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector

Series CM2 stainless steel cylinders are compact, lightweight and offer high performance. Improved piston seal and rod seal greatly improve the units life. Rubber bumpers are standard. The CM2 series offers a variety of mounting options and is auto switch capable. Double acting single rod, Bore sizes: 20, 25, 32, and 40 *, Strokes from 25mm through 500mm, Mounts: basic, foot, front and rear

(M)(L)(Z) D-A93(M)(L)(Z) M9// Without auto switch (with magnet) * Standard lead wire length is 0.5 m.

Note 4) Figures in ( ) in the table W are D-A93.

-X168 (Example) MY2H40G-599L-A93-XB10 Symbol Symbol 2 Long Stroke -XB11 4 Copper-free 20Available with long strokes exceeding the standard strokes.

Please contact SMC regarding water resistant types with the above model numbers. 2: 1 m type lead wire is only applicable to D-A93.

Note 4) ( ) in column W is the dimensions of D-A93.

Please contact SMC regarding water resistant types with the above model numbers. 2 1 m lead wire is only applicable to the D-A93. None N (Example) H7CN Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Since there are other applicable auto switches than listed above, refer to page 111 for details.

Symbol Nil A B C D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Solid state auto switch Reed auto switch (Not applicable to flange size 16) Without auto switch (with built-in magnet) Standard lead wire length is 0.5 m.

44.5 A 19.5 29.5 35.5 43 44 53 D 7.5 5 2 5 7 7.5 MY 6 10 15 20 25 32 CY MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.

Auto Switch Internal Circuit D-A90 Contact protection box OUT () Brown Reed switch Unit: g Weight CD-P11 OUT () Blue CD-P12 D-A90 D-A93 D-A96 Auto switch part no. 0.5 6 6 8 41 Lead wire length (m) 3 30 30 D-A93 LED diode Brown OUT (+) Brown Contact protection box Resistor Dimensions Unit: mm Reed switch Zener diode CD-P11 D-A90/D-A93/D-A96 CD-P12 OUT () Blue Blue D-A96 DC (+) Brown Indicator

D-m D-A93 D-M9m D-M9mW Less than 50 strokes Less than 20 strokes Less than 55 strokes Note) The above diagram is a note for installing 2 of D-A93, M9m, or M9mW auto switches.