SMC Corporation of America
Elite Part Number Search
Search Results "CDG5EA63TNSV-400-G5BASAPC"

V as standard) Outdoor installation IPX4 (400 V as standard) HRS100/150 Standard type 1.0 5 to 35 V V (400 V as standard, 200 V as an option) HRSH090 Inverter type 0.1 5 to 40 V Indoor use (Only 200 V as an option) (400 V as standard, 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 V V V V V (Only 200 V as an option) 195 Thermo-chiller Basic Type HRSE Series

300 600 0 150 100 50 200 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] AFM40-D AFD40-D 0.02 0.02 Pressure drop [MPa] Pressure drop [MPa] P1 = 0.5 MPa P1 = 0.3 MPa P1 = 0.5 MPa P1 = 0.3 MPa P1 = 0.7 MPa P1 = 0.7 MPa 0.01 0.01 0 0 0 600 400 200 800 1000 0 100 200 500 400 300 600 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 72 AFM20-D to AFM40-D Series AFD20-D to AFD40-D Series Dimensions

200 400 200 400 200 Pushing speed [mm/s] *2 35 or less 30 or less Actuator specifications Max. acceleration/deceleration[mm/s2] 5000 Positioning repeatability [mm] 0.01 Lost motion [mm] *3 0.1 or less Lead [mm] (including pulley ratio) 12 6 20 10 16 8 Impact/Vibration resistance [m/s2] *4 50/20 Ball screw Ball screw(In-line) Actuation type Belt[1.25:1] Ball screw Ball screwBelt(parallel)

Find the energy cost per hour of a double acting cylinder with an 80 mm. dia. and a 400 mm. stroke with t2 double strokes per minute and a working pressure of 6 bar In table 6.19 we see that an 80 mm dia. cylinder consumes 3.5 liters (approx.) per 100 mm stroke so: O /100 mm stroke . 400 mm stroke . number ot strokes per min . forward and retum stroke = 3.5 ' 4 . 24 = 336 Umin.

Load mass kg Load mass kg MY2HT25 Horizontal impact: P = 0.5MPa MY2H25 Horizontal impact: P = 0.5MPa 2000 1500 2000 1500 H unit Impact speed mm/s Impact speed mm/s Impact speed mm/s 1000 1000 H unit L unit 500 400 300 500 400 300 L unit Air cushion Air cushion Caution 200 200 Do not use a shock absorber and air cushion together. 100 1 2 3 4 5 10 20 50 40 1001 2 3 4 5 10 20 30 4050 30 Air

300 500 400 300 200 200 100 1 2 3 4 5 10 20 30 1002 3 4 5 10 20 30 0.5 40 50 100 Load weight (kg) Load weight (kg) 20 Horizontal collision: P = 0.5 MPa 40 Horizontal collision: P = 0.5 MPa 2000 1500 2000 1500 Collision speed (mm/s) Collision speed (mm/s) L unit 1000 1000 Air cushion 500 400 300 500 400 300 L unit Air cushion 200 200 1002 3 4 5 10 20 50 100 1 2 3 4 5 10 20 30 400 50 Caution

Outlet air flow rate (L/min (ANR)) 0 200 400 600 800 1000 1200 Outlet air flow rate (L/min (ANR)) 0 500 1000 1500 2000 Outlet air flow rate (L/min (ANR)) Pressure Characteristics Pressure Characteristics Pressure Characteristics Inlet pressure: 0.7 MPa Outlet pressure: 1.0 MPa Flow rate: 20 L/min (ANR) Inlet pressure: 0.7 MPa Outlet pressure: 1.0 MPa Flow rate: 20 L/min (ANR) Inlet pressure

Find the energy cost per hour of a double acting cylinder with an 80 mm. dia. and a 400 mm. stroke with t2 double strokes per minute and a working pressure of 6 bar In table 6.19 we see that an 80 mm dia. cylinder consumes 3.5 liters (approx.) per 100 mm stroke so: O /100 mm stroke . 400 mm stroke . number ot strokes per min . forward and retum stroke = 3.5 ' 4 . 24 = 336 Umin.

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Magnet: D (Built-in), Mounting: L (Axial Foot), Style: N (Non-lube Rubber Bumper), Bore Size: 50mm, Thread: TN (NPT Ports; M5 for Air Cushion 20 & 25 Bore), Seal Material: V (FKM), Stroke: 50mm, Auto Switch: G5BA--Solid State, Water Resist., 2 Wire, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number: 2 pcs. (Or None in the Case of No Switch), X Option: X165US

Magnet: D (Built-in), Mounting: L (Axial Foot), Style: A (Non-lube Air Cushion), Bore Size: 63mm, Thread: TN (NPT Ports; M5 for Air Cushion 20 & 25 Bore), Seal Material: R (NBR), Stroke: 1100mm, Auto Switch: G5BA--Solid State, Water Resist., 2 Wire, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number: 2 pcs. (Or None in the Case of No Switch), X Option: X165US

Magnet: D (Built-in), Mounting: L (Axial Foot), Style: A (Non-lube Air Cushion), Bore Size: 63mm, Thread: TN (NPT Ports; M5 for Air Cushion 20 & 25 Bore), Seal Material: R (NBR), Stroke: 450mm, Auto Switch: G5BA--Solid State, Water Resist., 2 Wire, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number: 2 pcs. (Or None in the Case of No Switch), X Option: X165US

Magnet: D (Built-in), Mounting: B (Basic Style), Style: N (Non-lube Rubber Bumper), Bore Size: 20mm, Thread: TN (NPT Ports; M5 for Air Cushion 20 & 25 Bore), Seal Material: V (FKM), Stroke: 50mm, Auto Switch: G5BA--Solid State, Water Resist., 2 Wire, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number: 2 pcs. (Or None in the Case of No Switch), X Option: X165US

Magnet: D (Built-in), Mounting: E (Integral Clevis), Style: A (Non-lube Air Cushion), Bore Size: 50mm, Thread: TN (NPT Ports; M5 for Air Cushion 20 & 25 Bore), Seal Material: R (NBR), Stroke: 300mm, Auto Switch: G5BA--Solid State, Water Resist., 2 Wire, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number: 2 pcs. (Or None in the Case of No Switch), X Option

Magnet: D (Built-in), Mounting: L (Axial Foot), Style: N (Non-lube Rubber Bumper), Bore Size: 25mm, Thread: TN (NPT Ports; M5 for Air Cushion 20 & 25 Bore), Seal Material: R (NBR), Stroke: 100mm, Auto Switch: G5BA--Solid State, Water Resist., 2 Wire, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number: 2 pcs. (Or None in the Case of No Switch), X Option: X165US

Magnet: D (Built-in), Mounting: L (Axial Foot), Style: N (Non-lube Rubber Bumper), Bore Size: 40mm, Thread: TN (NPT Ports; M5 for Air Cushion 20 & 25 Bore), Seal Material: V (FKM), Stroke: 50mm, Auto Switch: G5BA--Solid State, Water Resist., 2 Wire, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number: 2 pcs. (Or None in the Case of No Switch), X Option: X165US

Magnet: D (Built-in), Mounting: B (Basic Style), Style: A (Non-lube Air Cushion), Bore Size: 40mm, Thread: TN (NPT Ports; M5 for Air Cushion 20 & 25 Bore), Seal Material: R (NBR), Stroke: 100mm, Auto Switch: G5BA--Solid State, Water Resist., 2 Wire, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number: 2 pcs. (Or None in the Case of No Switch), X Option: X165US

Magnet: D (Built-in), Mounting: B (Basic Style), Style: N (Non-lube Rubber Bumper), Bore Size: 20mm, Thread: TN (NPT Ports; M5 for Air Cushion 20 & 25 Bore), Seal Material: R (NBR), Stroke: 50mm, Auto Switch: G5BA--Solid State, Water Resist., 2 Wire, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number: 2 pcs. (Or None in the Case of No Switch), X Option: X165US

Magnet: D (Built-in), Mounting: B (Basic Style), Style: N (Non-lube Rubber Bumper), Bore Size: 40mm, Thread: TN (NPT Ports; M5 for Air Cushion 20 & 25 Bore), Seal Material: R (NBR), Stroke: 50mm, Auto Switch: G5BA--Solid State, Water Resist., 2 Wire, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number: 2 pcs. (Or None in the Case of No Switch), X Option: X165US

Magnet: D (Built-in), Mounting: B (Basic Style), Style: N (Non-lube Rubber Bumper), Bore Size: 80mm, Thread: TN (NPT Ports; M5 for Air Cushion 20 & 25 Bore), Seal Material: V (FKM), Stroke: 150mm, Auto Switch: G5BA--Solid State, Water Resist., 2 Wire, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number: 2 pcs. (Or None in the Case of No Switch), X Option: