nominal size (mm) Limited flow (dm3/min) Standard effective oil level stroke (mm) 100 300 750 200 600 1510 3660 300 890 2260 5490 400 1190 3010 7320 500 1480 3770 9150 600 4520 10980 700 12810 800 14640 50 150 63 100 160 36 88 217 Limited flow shows the limit of converter oil level speed (200 mm/s) which can maintain stability of converter oil level.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VT VP VG VP S070 VQ VKF VQZ VZ VS VFN Coil temperature rises: 1C (With power saving circuit) Sonic conductance C: 0.037 (Standard)/C: 0.076 (Large flow capacity) Series Flow characteristics C[dm3/(s bar)] b Cv Standard Large flow capacity V14 V14A 0.037
When P2 + 0.1 b, choked flow P1 + 0.1 293 Q = 600 x C (P1 + 0.1) (1) 273 + t When P2 + 0.1 > b, subsonic flow P1 + 0.1 2 P2 + 0.1 b P1 + 0.1 Q = 600 x C (P1 + 0.1) 1 (2) 1 b 293 273 + t Q : Air flow rate [dm3/min (ANR)], dm3 (Cubic decimeter) of SI unit are also allowed to described by l (liter). 1 dm3 = 1 l .
(IZS4-340/ 400/ 460/ 580/ 640) (IZS4-820/ 1120/ 1300) (c) Air supply from both sides (IZS4-1600/ 1900/ 2320/ 2500) 7.
Actuator Specifications Supplement 1.1 Initial setting of LEY/LEYG series Model LEY16/LEYG16 LEY25/LEYG25 LEY32/LEYG32 LEY40/LEYG40 Lead symbol A B C A B C A B C A B C Lead [mm] 10 5 2.5 12 6 3 16 8 4 16 8 4 Stroke (mm) 300 300 300 400 400 400 500 500 500 500 500 500 Max. speed [mm/s] 500 250 125 500 250 125 500 250 125 300 150 75 Min. speed [mm/s] (Independent and interpolation) 15 8 4 18
Vacuum switch unit Filter unit Release flow rate adjusting needle Manual operation Vacuum switch Electrical entry Ejector exhaust Electrical entry PV/V port size Pilot valve Components Vacuum switch unit Valve unit N.C. type Ejector unit ZX1 1 10 5 L Z E C K1 L Vacuum switch unit Ejector unit 1 10 L Z E C K3 5 ZX1 Valve unit N.O. type Vacuum switch unit ZX1 1 10 E C Ejector unit CE compliant
IDX-OM-V024-F PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDFB60-11-C,L,R,T,V IDFB60-23-C,L,R,T,V IDFB70-23-C,L,R,T,V IDFB80-23-C,L,R,T,V IDFB90-23-C,L,R,T,V This manual is intended to explain the installation and operation of the product.
C D 15 (mm) Auto switch model A D-F9 B C D D-A9 D-F9 D-A9 D-F9 D-A9 D-F9 Bore size (mm) 17.5 15 D-A9 21.5 76.5 72.5 56.5 60.5 Note) Auto switches cannot be installed in Area C in the case of 15. 25, 32 (mm) A D-Y5 D-Y7 D-Y7W B C D Auto switch model D-Y5 D-Y7 D-Y7W D-Y5 D-Y7 D-Y7W D-Y5 D-Y7 D-Y7W D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8 Bore size (mm) 25 22 101 103 47 47 78 78 22 32 30.5
Indication Item Setting and selection Setting range [High] Set the temperature range of the circulating fluid SP. +0.1 C to +10.0 C +1.0 C Upper/lower temperature limit (1) High/ Low [Low] Set the temperature range of the circulating fluid SP. -0.1 C to -10.0 C -1.0 C TEMP READY signal is output when the set time has passed after the circulating fluid temperature rises/drops within the
HOW TO O R D E R X T A1 NC A U T O S W I T C H C O N S T R U C T I O N T Y P E (PLEASE SEE PAGE 1 FOR CONSTRUCTION DETAILS) Standard D Auto Switch capable (Stainless and Steel Construction (1.5~14) All Stainless Steel (1.5~14) Steel w/ Composite Tube (1.5 14) Stainless Steel w/ Composite Tube (1.514) ST SS SCT SSCT ...
Monitoring start timer -06 0 to 600 minutes Range over detection timer 5 5 to 999 seconds AL05 High circulating return temp.
150 300 450 600 750 900 1050 1200 1350 Distance [mm] Distance [mm] 5) Supply pressure: 0.4 MPa Flow rate consumption: 316 L/min (ANR) 6) Supply pressure: 0.5 MPa Flow rate consumption: 390 L/min (ANR) 200 200 2 s 150 150 1.5 s 100 100 50 50 0.5 s 1 s 1.5 s 0.5 s 1 s 50 50 100 100 150 150 200 200 1500 0 150 300 450 600 750 900 1050 1200 1350 1500 0 150 300 450 600 750 900 1050 1200 1350 Distance
Indication Item Setting and selection Setting range [High] Set the temperature range of the circulating fluid SP. +0.1 C to +10.0 C +1.0 C Upper/lower temperature limit (1) High/ Low [Low] Set the temperature range of the circulating fluid SP. -0.1 C to -10.0 C -1.0 C TEMP READY signal is output when the set time has passed after the circulating fluid temperature rises/drops within the
Indication Item Setting and selection Setting range [High] Set the temperature range of the circulating fluid SP. +0.1 C to +10.0 C +1.0 C Upper/lower temperature limit (1) High/ Low [Low] Set the temperature range of the circulating fluid SP. -0.1 C to -10.0 C -1.0 C TEMP READY signal is output when the set time has passed after the circulating fluid temperature rises/drops within the
AMD AMH Data A: Inlet Air Temperature Data B: Ambient Temperature Data C: Inlet Air Pressure AME Inlet air temperature Ambient temperature Inlet air pressure MPa psi Correction factor F C Correction factor AMF Correction factor IDFB3E to 37E IDFB55E, 75E 1.31 F C 77 90 95 100 104 25 32 35 37.8 40 75 100 110 120 125 150 175 200 232 0.53 0.70 0.76 0.83 0.86 1.03 1.21 1.38 1.60 1.24 0.95 ZFC
600 600 600 Y 400 400 400 400 Mer m 200 200 200 200 0 0 0 0 0 10 20 30 40 50 0 10 20 30 40 50 60 0 2 4 6 8 10 12 14 16 0 4 8 12 16 20 24 Work load [kg] Work load [kg] Work load [kg] Work load [kg] 2000 2000 2000 2000 Mep 1500 1500 1500 1500 L3 [mm] L3 [mm] L3 [mm] L3 [mm] m 1000 1000 1000 1000 L3 Z 500 500 500 500 0 0 0 0 0 10 20 30 40 50 0 2 4 6 8 10 12 14 16 0 4 8 12 16 20 24 0 10 20 30
A A a B B s j C f g t C0.5 C0.2 C0.2 b d e 45 45 Section A-A p k C0.5 45 C n h i l (d) C0.5 q m O Section B-B r (l) View C (mm) +0.2 0 l i o j k m n p q r s t b e g a c d f h Model 0 0.2 0.05 0.15 + 0.1 0 +0.2 0 3.5 +0.013 +0.001 CXS 6 2.75 M2.5 x 0.45 4.5 3.5 4.75 C0.5 2.8 0.5 4 3.5 3 3.5 16 0.1 M3 x 0.5 4 1 5.5 6 +0.2 0 0.05 0.15 0 0.2 + 0.1 0 +0.2 0 5 +0.016 +0.001 CXS10 4 M3 x 0.5 8 5
Built-in magnet for auto-switches CE1 CE2 Maximum Driving Speed of Cylinders ML2B 1000 1000 900 900 C J G5-S Load factor: 10% Load factor: 50% 800 800 Cylinder speed (mm/s) Cylinder speed (mm/s) 700 700 600 600 CV 500 500 400 400 MVGQ 300 300 200 200 CC 100 100 0 0 12 16 20 25 32 40 50 63 80 100 RB SYJ3000 VZ3000 VZ5000 VF3000 Bore size (mm) J Series Variations DDetailed specifications
Air flow SW:1 10 10 Air flow SW:10 5 5 Air flow SW:10 0 0 0 200 400 600 800 1000 1200 1400 1600 0 200 400 600 800 1000 1200 1400 1600 Installation distance mm Installation distance mm 28 Doc.