PEND Water-glycol, Emulsion For 2 1/2B, 3B CW-6H-W Phosphoric ester CW-6H-V Petroleum D-73H For 1/2B to 1B Water-glycol, Emulsion D-73H-W Phosphoric ester D-73H-V Petroleum D-74H For 1 1/4B to 2B Cap Water-glycol, Emulsion D-74H-W Phosphoric ester D-74H-V Petroleum D-75H Water-glycol, Emulsion For 2 1/2B, 3B D-75H-W Phosphoric ester D-75H-V 10 Suction Guard Series FHG How to Order FH G 9
With auto switch: MDSUB3 1) 24: When using D-90/90A/S99(V)/T99(V)/S9P(V) 30: When using D-97/93A 2) 60: When using D-90/90A/97/93A 69: When using D-S99(V)/T99(V)/S9P(V) CRB2 If the adjustment bolt is removed, rotation will be approximately 270 for the single vane type and 100 for the double vane type.
/D-Y7P(V) D-Y7NW(V)/Y7PW(V)/Y7BW(V) D-Y7BAL BU-1 BU-1 BU-1 BU-1 A B A B
F.S. = 5[V] 1[V] = 4[V] 3[%F.S.] = 4 X 0.03 = 0.12[V] Detection Analog output voltage [V] Pressure indication [kPa] Switch The output error induced by the temperature change can be as much as 0.12[V]. 1.12 1 0.88 P3 0 Vacuum Pressure Rated pressure P1 P2 103 100 97 Pressure display = 100[kPa] Temperature characteristic = 3[%F.S.]
TI/ TIL Table (2) Rated Voltage-Electrical Entry-Electrical Option Table (1) Connection Size and Applicable Model PA Insulation type Electrical entry Electrical option 1 (100 V) 2 (200 V) 3 (110 V) 4 (220 V) 7 (240 V) 8 (48 V) 5 (24 V) 6 (12 V) Class B Class H G Connection Applicable model VXD2142-03 VXD2142-04 VXD2152-06 VXD2262-10 VXD2272-32 VXD2382-40 VXD2392-50 Size PAX C D, T G, C T
H 364 H 364 J 116 H 364 V 564 H 364 K 332 J 116 J 116 J 116 V 564 J 116 K 332 V 564 V 564 V 564 K 332 K 332 K 332 Table B FLOW CONFIGURATION VALVE NO.
H 364 H 364 J 116 H 364 V 564 H 364 K 332 J 116 J 116 J 116 V 564 J 116 K 332 V 564 V 564 V 564 K 332 K 332 K 332 Table B FLOW CONFIGURATION VALVE NO.
When D-A9(V)/M9(V)/M9W(V)/M9A(V)L types with 32 to 50 are mounted on a side other than the port side, order auto switch mounting brackets separately. Refer to page 836 for details.
47.5 43.5 50 40 42 47.5 48.5 54.5 51 54 50 56.5 REB REC Operating Range CY (mm) Bore size Auto switch model 32 40 50 63 CX D-A9 (V) 9.5 9.5 9.5 11.5 MQ D-M9 (V) D-M9W (V) D-M9A (V) L D-A7 (H) (C) D-A80 (H) (C) 6 5.5 6 6.5 RHC 12 11 10 12 RZQ D-A79W 13 14 14 16 D-F7 (V) D-J79 (C) D-F7W (V) D-F7BA (V) D-F7NTL D-F79F 6 6 6 6.5 D-X D-P4DW 5 5 5 Individual -X Since the operating range is provided
Thread Rc G NPT Nil None V V V A Yes 6 V B 1/4* V Z With light/surge voltage suppressor Port size Port size VP500 VP700 03 3/8" V 04 1/2" V * For internal pilot, the symbol is nil. * Refer to Piping for External Pilot Type on page 4 for selection of the check valve.
When mounting D-A9(V)/M9(V)/M9W(V)/M9A(V)L types on a side other than the port side as for bore 32 to 50, order auto switch mounting brackets separately. Refer to page 860 for details.
Note 12 16 20 25 32 40 50 D-F7 , J79 D-F7 V D-J79C D-F7 W, J79W D-F7 WV D-F7BAL, F7BAVL D-F79F D-F7NTL D-F7, D-F7V D-J79, D-J79C D-F7W, D-F7WV D-J79W D-F7BAL, D-F7BAVL D-F7NTL, D-F79F -X Switch mounting screw (M3 x 0.5 x 10 ) Switch spacer Switch mounting nut D-A7 , A80 D-A73C, A80C D-A7 H, A80H D-A79W 6 6 6 32, 40 50 BQ-2 20Data D-F9W, D-F9WV D-F9BAL 5.5 3 4 5 5.5 5.5 5.5 Switch mounting
With auto switch: MDSUB3 1) 24: When using D-90/90A/S99(V)/T99(V)/S9P(V) 30: When using D-97/93A 2) 60: When using D-90/90A/97/93A 69: When using D-S99(V)/T99(V)/S9P(V) CRB2 CRBU2 If the adjustment bolt is removed, rotation will be approximately 270 for the single vane type and 100 for the double vane type.
-Y (Copy function switch output) -V/-T (Copy input mode) PNP open collector output type-2 output Max. 28 V, 80 mA Residual voltage 1 V or less -23No.PS-OMU0009-D Outline of Settings [Measurement mode] Power is supplied.
(example: If the Pressure switch with output impedance of 1k is connected to the A/D converter to detect the analogue output of 5V, the detected voltage by the A/D converter becomes 5(V) 1(M)/(1(k) + 1(M)) 4.995(V), and there is an error of approximate 0.005 V). Output impedance Output type The operation type of the switch output.
Lead wire length (m) Auto switch model Electrical entry direction Load voltage Wiring (Output) Special function Electrical entry Indicator light Type 0.5 (Nil) 3 (L) Applicable load AC DC 12 V In-line A93 Reed auto switch 2-wire Grommet Yes Relay, PLC 100 V 24 V M9N 3-wire (NPN) 12 V Solid state auto switch Grommet Yes Relay, PLC 24 V M9B 2-wire 12 V Lead wire length symbols 0.5 mNil
[Series CKG1 / Built-in standard magnet] D-P4DWSC, D-P4DWSE, D-P4DWL/Z (AC magnetic field) [Series CKP1 / Built-in strong magnet] D-P79WSE, D-P74L/Z (DC/AC magnetic fields) Switch mounting rod Switch mounting bracket The auto switch mounting and the piping position are available in three-way directions. The auto switch mounting position can be altered.
There is a danger of malfunction or damage to the reduced wiring system or input/output equipment. +24 V +24 V Power supply for output Power supply for output 0 V 0 V Power supply for control/input +24 V Power supply for control/input 24 V 4. Do not install a unit in a place where it can be used as a foothold.
Pin description Load is an analog input equipment such as a voltmeter, ammeter. 1 DC(+) PF2A7H-(-M) 68 69 2 Analog output 3 DC() Accumulated pulse output wiring examples 4 OUT1 4-I thread with depth J 40 Max. 30 V 80 mA or less OUT1 Load Black H 0 V or Blue 50 msec 50 msec PF2A7H-(-M) 28 29 B C D E F G H I J A Model Brown PF2A703H PF2A706H PF2A712H 55 160 40 92 67 55 Rc1, NPT1, G1 36 M5 x