0.2F.S.(25 IP65 AC500V 1 100M(DC500 V) -1060 -2070 () 3585RH() CERoHS 01 02 R1/8M50.8 R1/4M50.8 C3604+ Al2O3(96) OFKM+ M12 88 g 95 g M12 175 g 182 g AWG23 0.72 mm 1.14 mm 4 3 m -15No.PS-OMS0004CN-D [mA] [V] A B 01MPa 0 1MPa -100100 kPa -100 kPa 100 kPa 0500 kPa 0 500 kPa -16No.PS-OMS0004CN-D A B PSE57-01 8 R1/8 PSE57-02 12 R1/4 M12 ZS-37-A 1 2 4 3 M12 ZS-37-B 3 4 2 1
31 32 35 30 30 03 3F 38 0D Answer 25.0 deg.C. 31 Temperature setting (without writing FRAM) No 02 31 32 35 30 30 03 3F 38 0D 06 0D Set at 25.0 deg.C 32 Reading internal sensor No 05 32 33 32 0D 02 32 32 35 30 32 03 3F 3B 0D Answer 25.02 deg.C 33 Reading external sensor No 05 33 33 33 0D 02 33 33 30 30 32 03 3F 38 0D Answer 30.02 deg.C 34 Reading alarm status No 05 34 33 34 0D 02 34 30 38
Supply pressure: 0.7 MPa Set pressure: 0.2 MPa Flow rate: 0 /min (ANR) Back pressure: 0.5 MPa Supply pressure: 0.5 MPa IR2000-02 IR2000-02 IR2000-02 0.204 0.5 0.2 Set pressure P2 (MPa) Set pressure (MPa) Set pressure (MPa) 0.4 0.202 F.R.L.
(With NPN output) 1 V or less (With load current of 80 mA) 1 s (0.25, 0.5, 2, 3) Yes 1% F.S.
(With NPN output) 1 V or less (With load current of 80 mA) 1 s (0.25, 0.5, 2, 3) Yes 1% F.S.
Example) AR30-03BG-NR-B-X425 Symbol Description Nq Body size 25 30 40 50 60 Symbol Description Nq Body size 20 25 30 40 50 60 Nw Pipe thread type Nil Rc N NPT F G + Nw Pipe thread type Nil Rc N NPT F G + 02 1/4 03 3/8 04 1/2 06 3/4 10 1 + Ne Port size 01 1/8 02 1/4 03 3/8 04 1/2 06 3/4 10 1 + Ne Port size Nil Without mounting option B*2 With bracket a Mounting Option *1 H With set nut (for
Panel mount E Lead wire length 3m L Panel mount + Front protection cover Analog output Suitable model: ZSE50F/ISE50--22/62(L)-(M) F Series ISE50 Series ZSE50F Analog output value (V) Analog output value (V) 5 5 1 1 Unit specification 1.0MPa 0 100kPa 100kPa Note 1) Nil M With unit switching function Note 2) Fixed SI unit Pressure Pressure Note 1) Under the New Measurement Law, which has been
Panel mount E Lead wire length 3m L Panel mount + Front protection cover Analog output Suitable model: ZSE50F/ISE50--22/62(L)-(M) F Series ISE50 Series ZSE50F Analog output value (V) Analog output value (V) 5 5 1 1 Unit specification 1.0MPa 0 100kPa 100kPa Note 1) With unit switching function Nil M Note 2) Fixed SI unit Pressure Pressure Note 1) Under the New Measurement Law, which has been
) Note 13) v v v v v XC9 Note 15) Note 14) Note 14) v v v v v v v XC10 v v v v v v v XC11 v v v v v XC12 v v v v XC13 v v v v XC20 Note 15) v v v XC22 Note 2) v v v v v v XC27 v v v v v v v XC29 v v v v XC35 v v v v v v v XC37 v v v v v XC42 v v v XC85 X446 Note 8) Copper-free for the externally exposed part.
Data
5 AS-FG AS-FP AS-FM AS321F-02 Meter-out type AS3201F-02 Meter-in type AS3211F-02 AS-D AS-T ASP ASN AQ ASV AK VCHC ASR ASQ Component Parts No.
Operation of the cylinder with its body fixed will damage the wear ring, resulting in increase of particle generation or malfunction. 12-REA40 10-AS2001F-06-X214 10-AS2301F-02-06-X214 10-AS2201F-02-06-X214 12-REA50 10-AS3001F-08-X214 10-AS3301F-02-08-X214 10-AS3201F-02-08-X214 12-REA63 10-AS3001F-08-X214 10-AS3301F-02-08-X214 10-AS3201F-02-08-X214 Although speed adjustment is possible with
RZQ
MLGP
Nil Rc V V V V V N*1 NPT V V V V V F*2 G V V V V V + 01 1/8 V 02 1/4 V V V 03 3/8 V V 04 1/2 V 06 3/4 V 10 1 V V r Port size + a Mounting Nil Without mounting option V V V V V B*3 With bracket V V V V V + Option t Nil Without auto drain V V V V V b Float type auto drain C*4 N.C.
J79W F7BA 200 V 100 V Relay, PLC Yes 2-wire 12 V Connector 24 V Grommet Diagnostic indication (2-color indication) 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Grommet 2-wire 12 V Connector 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Diagnostic indication (2-color indication) Yes Relay, PLC 24 V Water resistant (2-color indication) 12 V 2-wire Grommet With diagnostic output
C76
Data
Data
Data