14 18 18 22 26 27 36 5 7 8 8 10 10 13 16 23 27 30 31 37 40 45 55 11 11 14 14 19 19 42 52 74 84 90 98 116 126 160 180 17 19 24 24 30 30 41 55 136 153,5 173 184,5 215 231 287 340 36 40,5 45 48,5 52 57 65 80 6 6 10 10 16 20 15 15 7 10 11 11 11 12 20 25 10 10 10 10 14 14 26 31 32 40 50 63 80 100 125 160 C92S B-Stroke W Bore (mm) AM D EE G H J KK K KW M N S SW VD WH ZZ B 22 24 32 32 40 40 54
A to B C to D 1 L 0.01 to 1.0 -0.05 to 1.05 2 L 0.02 to 2.0 -0.1 to 2.1 5 L 0.05 to 5.0 -0.25 to 5.25 10 L 0.1 to 10.0 -0.5 to 10.5 L/min 25 L 0.3 to 25.0 -1.3 to 26.3 50 L 0.5 to 50.0 -2.5 to 52.5 100 L 1.0 to 100.0 -5.0 to 105.0 200 L 2.0 to 200.0 -10.0 to 210.0 PF2M7 40 to 4000 -200 to 4200 1 L 0.4 to 35.3 -1.8 to 37.1 Cfm x 10-3 2 L 0.7 to 70.6 -3.5 to 74.2 5 L 0.002 to 0.177 -0.009 to
connector (Station n)(Station 1) VQ7 (mm) EVS 2 110.5 100 88 11.5 3 135.5 125 104 16 4 148 137.5 120 14 5 160.5 150 136 12.5 6 185.5 175 152 17 7 198 187.5 168 15 8 210.5 200 184 13.5 9 223 212.5 200 11.5 10 248 237.5 216 16 Stations L1 L2 L3 L4 VFN U D VV4Z1-25FUStation -00C (2 to 10 stations) VV4Z1-25F Station B-00C (2 to 10 stations) VV4Z1-25F Station -00C (11 to 20 stations) U D D side
Low Speed Cylinder Double Acting, Single Rod Series CJ2X 10, 16 How to Order Bore size 10 16 10 mm 16 mm Standard stroke (mm) 10 16 15, 30, 45, 60, 75, 100, 125, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Intermediate stroke other than above is manufactured upon receipt of order.
Low Speed Cylinder Double Acting, Single Rod Series CJ2X 10, 16 How to Order Bore size 10 16 10 mm 16 mm Standard stroke (mm) 10 16 15, 30, 45, 60, 75, 100, 125, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Intermediate stroke other than above is manufactured upon receipt of order.
177 202 51 25 12.5 25 150 227 37.5 50 75 100 125 101 114 126 139 164 189 214 56 29 12.5 25 150 239 175 200 264 289 37.5 50 75 100 125 101 114 126 139 164 189 214 61 29 12.5 25 150 239 175 200 264 289 125 10 75 27 20 30 40 60 80 100 120 130 140 150 170 190 210 120 230 270 140 160 180 200 250 290 310 With Mounting Bracket Refer to Basic/(B) for other dimensions and with rod boot.
] 4 Thermo-chiller Series HRS Heating Capacity 012 018 024 A W HRS -10 (Single-phase 100/115 VAC) 1000 1000 Ambient 20C Ambient 32C Heating capacity [W] Heating capacity [W] Heating capacity [W] Heating capacity [W] Ambient 40C Ambient 25C 800 800 Ambient 20C Ambient 25C Ambient 32C Ambient 40C 600 600 400 400 200 200 Ambient 5C Ambient 5C 0 5 10 15 20 25 30 35 40 45 0 5 10 15 20 25 30 35
Model Description AC10B G27-10-R1 G27-10-R1 (3) AD17 Y100 AC25B G36-10-01 GC3-10AS G36-2-01 GC3-2AS AD38 AD38N (7) AC30B G36-10-01 GC3-10AS G36-2-01 GC3-2AS AD38 AD38N (7) AC40B G46-10-02 GC3-10AS G46-2-02 GC3-2AS AD48 AD48N (7) AC40B-06 G46-10-02 GC3-10AS G46-2-02 GC3-2AS AD48 AD48N (7) AC50B G46-10-02 GC3-10AS G46-2-02 GC3-2AS AD48 AD48N (7) AC55B G46-10-02 GC3-10AS G46-2-02 GC3-2AS
IN side OUT side Fitting size Straight Elbow Elbow Elbow Straight Elbow Elbow Elbow R S T U V W X Y 4, 5/32 2.5 6 11 35.5 6 3 12.5 19 35.5 3 6.5 11 36 1/4 3 12.5 19 35.5 6.5 6 11.5 38.5 8, 5/16 5 13.5 21 38.5 ARM5AB Centralized supply type (DIN rail mount) n = Number of stations for regulator block L2 L2-10.5 L1=(14 x n)+56 11.5 Y Pressure gauge (Accessory) 10 10 14 14 16 10 10 5.3 W V T
Piston speed [mm/s] Maximum air consumption Q [Nl/min.] 100 125 2 300 400 500 300 400 500 80 150 200 150 200 63 50 100 100 32 40 30 40 50 30 40 50 25 20 20 20 15 15 16 10 10 8 2000 10 5 4 1500 3 1000 2 6 500 400 300 1 1 200 0.5 100 0.2 0.3 0.4 0.5 0.6 0.7 0.8 Working pressure [MPa] 1.8-26 Series CP95 Average air consumption of compressed air cylinders and piping Thermal loss is not represented
), PPS, Silicone, Brass 3-phase 200 VAC 50 Hz, 3-phase 200 to 208 VAC 60 Hz Allowable voltage fluctuation 10% 30 25 26 25 Refer to page 94.
SY3120-C6 Horizontal actuation 800 700 600 500 400 300 200 100 0 SY5120-01 800 700 600 500 400 300 200 100 0 SY7120-02 800 700 600 500 400 300 200 100 0 SY9120-03 Base mounted Bore size Series CJ2 Pressure 0.5 MPa Load rate: 50% Stroke 60 mm Series CS1 Pressure 0.5 MPa Load rate: 50% Stroke 1000 mm 6 10 16 125 140 160 180 200 20 25 32 40 40 50 63 80 100 Series MB/CA2 Pressure 0.5 MPa Load
(mm) 40 50 63 80 CA2-B04 CA2-B05 CA2-B06 CA2-B08 CA2-B10 +0.058 0 57 35 11 65 15 85 10 9 17 8 40 52 60 165 10 +0.070 0 57 35 11 65 18 85 10 9 17 8 40 52 70 183 12 +0.070 0 67 40 13.5 80 25 105 12.5 11 22 10 50 66 85 196 16 +0.084 0 93 60 16.5 100 31.5 130 15 13.5 24 12 65 90 102 235 20 100 +0.084 0 93 60 16.5 100 35.5 130 15 13.5 24 12 65 90 116 256 25 10 Series CA2 Dimensions of Accessories
15% +10% 15% Single phase 200 to 230VAC (50/60HZ ) For 100V Single phase 100 to 115VAC (50/60HZ ) R T 1MCCB Equipment Connection Example Noise filter External noise is prevented by the noise filter.
FLT 09 Alarm10*1 10 Alarm11 Reservoir High Temp.
5 6 7 8 9 1 0 1 11 2 1 31 41 5 7 8 9 10 11 Distance from cylinder shaft center Lo (cm) Distance from cylinder shaft center Lo (cm) CY3R20 CY3R40 500 200 300 100 200 50 100 20 30 40 50 30 10 Useable range 10 5 5 Useable range 1 0 1 2 3 4 5 6 1 7 8 9 10111213 0 1 2 3 4 5 6 7 8 9 1 0 1 11 2 1 31 41 5 Distance from cylinder shaft center Lo (cm) Distance from cylinder shaft center Lo (cm) CY3R25
5 6 7 8 9 1 0 1 11 2 1 31 41 5 7 8 9 10 11 Distance from cylinder shaft center Lo (cm) Distance from cylinder shaft center Lo (cm) CY3R20 CY3R40 500 200 300 100 200 50 100 20 30 40 50 30 10 Useable range 10 5 5 Useable range 1 0 1 2 3 4 5 6 1 7 8 9 10111213 0 1 2 3 4 5 6 7 8 9 1 0 1 11 2 1 31 41 5 Distance from cylinder shaft center Lo (cm) Distance from cylinder shaft center Lo (cm) CY3R25
Model Model L D L D TCU0805-1-N-X6 TCU0425-1-N-X6 1 N x 8 31 3 to 90 L x 5.2 + 200 N x 4 18 1 3 to 90 L x 5.9 + 200 8 5 TCU0805-2-N-X6 TCU0425-2-N-X6 2 42 3 to 40 L x 3 + 200 N x 16 L x 4.4 + 200 N x 8 2 3 to 90 4 2.5 28 TCU1065-1-N-X6 TCU0425-3-N-X6 1 52 3 to 45 L x 5 + 200 N x 10 N x 12 3 3 to 63 L x 2.9 + 200 28 10 6.5 TCU1065-2-N-X6 TCU0604-1-N-X6 2 3 to 35 N x 20 52 L x 3 + 200 N x 6
less 31 49 37 5 or less 20 190 35 62 50 10 or less 39 66 33 5 or less 30 190 39 68 43 10 or less 43 72 29 5 or less 50 190 49 83 33 10 or less 53 87 22 5 or less 70 190 54 95 30 10 or less 58 99 21 5 or less 100 190 61 108 27 10 or less 65 112 18 5 or less 200 190 81 139 21 10 or less 85 143 15 5 or less Operating range m: Value of the operating range Lm of a single auto switch converted
(2) (10.2) 50 [ms] 40 30 T8 T9 20 T7 10 T6 T5 0 0 1000 2000 3000 4000 5000 6000 [r/min] LE-T10.3.2 [] LE-T5LE-T6LE-T730 LE-T8LE-T910 6 10. 10.4 a 1 10 8 5 10 7 1 10 7 5 10 6 a: [ms] 1 10 6 5 10 5 b: SSCNET 1 10 5 5 10 4 1 10 4 b 5 10 3 1 10 3 4 7 10 20 40 70 100 200 [mm] 10.5 2500kVA1mAC240V()LECSS2T5LECSS2-T9AC200V (A0-P) (L1L2L3) (L11L21) LECSS2-T5LECSS2-T7 LECSS2-T8