Size: M5, Thread: M Thread, Rc(PT), Port Size: M5 x 0.8, Accessory: Pressure Gauge, Attachment: None, Option 1: None, Option 2: Flow Direction: Right->Left, Option 3: Name Plate, Caution on Bowl
Size: M5, Thread: M Thread, Rc(PT), Port Size: M5 x 0.8, Accessory: Pressure Gauge, Attachment: None, Option 1: None, Option 2: None, Option 3: Name Plate, Caution on Bowl
Size: M5, Thread: M Thread, Rc(PT), Port Size: M5 x 0.8, Accessory: Pressure Gauge, Attachment: None, Option 1: Lubricator w/Drain Cock, Option 2: None, Option 3: Name Plate, Caution on Bowl
Size: M5, Thread: M Thread, Rc(PT), Port Size: M5 x 0.8, Accessory: None, Attachment: None, Option 1: Nylon Bowl, Option 2: -, Option 3: -
Size: M5, Thread: M Thread, Rc(PT), Port Size: M5 x 0.8, Accessory: Pressure Gauge, Attachment: None, Option 1: Metal Bowl, Option 2: None, Option 3: Name Plate, Caution on Bowl
Size: M5, Thread: M Thread, Rc(PT), Port Size: M5 x 0.8, Accessory: None, Attachment: None, Option 1: Lubricator w/Drain Cock, Option 2: None, Option 3: Name Plate, Caution on Bowl
Size: M5, Thread: M Thread, Rc(PT), Port Size: M5 x 0.8, Accessory: C+G, Attachment: -, Option 1: -, Option 2: -, Option 3: -
Size: M5, Thread: M Thread, Rc(PT), Port Size: M5 x 0.8, Accessory: Pressure Gauge, Attachment: None, Option 1: Lubricator w/Drain Cock, Option 2: -, Option 3: -
Size: M5, Thread: M Thread, Rc(PT), Port Size: M5 x 0.8, Accessory: None, Attachment: None, Option 1: Nylon Bowl, Option 2: None, Option 3: Name Plate, Caution on Bowl
Size: M5, Thread: M Thread, Rc(PT), Port Size: M5 x 0.8, Accessory: Pressure Gauge, Attachment: None, Option 1: Metal Bowl, Option 2: -, Option 3: -
Size: M5, Thread: M Thread, Rc(PT), Port Size: M5 x 0.8, Accessory: C+G, Attachment: None, Option 1: None, Option 2: None, Option 3: Name Plate, Caution on Bowl
Type: 332 (Body Ported), Valve Option: Y (For Low Wattage), Rated Voltage: 5 (24 VDC), Electrical Entry: G (Grommet, Lead Wire 300mm), Light/Surge Voltage Suppressor: None, Port Size: M5 (M5 x 0.8)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: M5 (M5 Female Thread), Option 1: w/o Lead Wire, Option 2: A1 (Bracket A, Vertical Mounting), Option 3: Y (w/o Operation Manual, w/o Calibration Certificate)
Intermediate brackets should be mounted at the same intervals. 3) Installation of the ionizer (when using brackets) M4 screw Tap (M5) screws at the bracket mounting positions for installation of the ionizer and fix the ionizer body and brackets with M5 screws.
F G H [Tightening torque] No.LZ-OM00401 B (1/3) Electric Cylinder LZC series L[]ZC[]3[] 1.5 8 M4 x 0.7 x 6 deep [0.75Nm ] L[]ZC[]5[] 3 13 M5 x 0.8 x 8 deep [1.5Nm ] L[]ZC[]3[] M4 screw 0.75Nm M4 screw 0.75Nm L[]ZC[]3[] 4.5 8 2 7.5 11.5 12 L[]ZC[]5[] 6.5 13 3.2 10.7 16.7 15 L[]ZC[]5[] M5 screw 1.5Nm M6 screw 2.6Nm Model no.
. *7 With lock only *8 For an actuator with lock, add the power consumption for the lock. 13 Battery-less Absolute Encoder: Electric Actuator/High Rigidity and High Precision Slider Type LEKFS Series Battery-less Absolute (Step Motor 24 VDC) Dimensions: In-line Motor LEKFS25E (102) 64 3H9 (+0.025 0 ) depth 3 Body mounting reference plane (B dimension range)1 4 x M5 x 0.8 thread depth 8.5
across flats 36 80 [mm] Optional specifications With bracket With built-in silencer Model K L M N P Q R S T U V W X Y AV2000-m02-1 to 6D/Y(Z)m-A 30 50 51.5 44 5.5 10 66 2.3 33.5 54 M4 x 0.7 Depth 6 3 Width across flats 14 AV3000-m03-1 to 6D/Y(Z)m-A 41 50 53.5 46 5.5 15 70 2.3 33.5 54 M4 x 0.7 Depth 6 3 Width across flats 19 AV4000-m04-1 to 6D/Y(Z)m-A 50 60 64 54 8.5 18 90 3.2 39 74 M5
Refer to page 97 for details. 67 Regulator Series AR10-A Regulator Series AR20-B to AR60-B Regulator with Backflow Function Series AR20K-B to AR60K-B Flow-rate Characteristics (Representative values) Condition: Inlet pressure 0.7 MPa AR10-A M5 AR20(K)-B Rc1/4 AR25(K)-B Rc3/8 AC AF+AR+AL AW+AL AF+AR AF+AFM+AR AW+AFM AF Attachment AFM / AFD AR AL AW 0.6 0.6 0.6 0.5 0.5 0.5 Outlet pressure (
) shows the nominal filtration accuracy. 5 Valve Rc1/2 Cable Specifications Power Supply Cable and Earth Leakage Breaker (Recommended) Recommended crimped terminal Cable specifications Earth leakage breaker Breaker size [A] Sensitivity current [mA] Terminal block screw diameter Model Power supply voltage specifications HRL100-Am-20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) M5
415 VAC (50/60 Hz) 20 A M5 4 cores x 5.5 mm2 (4 cores x AWG10) (Including grounding cable R5.5-5) R5.5-5 HRS150-Al-40-l HRS150-Wl-40-l Note) An example of the cable specifications is when two kinds of vinyl insulated wires with a continuous allowable operating temperature of 70C at 600 V, are used at an ambient temperature of 30C.