Dimensions Applicable tubing O.D. d Inch Size Metric Size L3 Model L3 Model Weight (g) 6 7 8 12 13 26 31 Weight (g) 6 7 8 9 12 18 21 24 26 31 M1 d M1 D2 L2 D1 L1 D2 L2 D1 L1 d Min. 24.9 25.5 Min. 24.9 25.5 26.6 27.6 28.7 30.2 31.5 Max. 27.7 28.5 Max. 27.7 28.5 29.8 32.6 33.7 35.2 36.5 3.2 4 6 4 6 6 8 AS1001FM-23 AS1001FM-04 AS1001FM-06 AS2001FM-04 AS2001FM-06 AS2051FM-06 AS2051FM-08 AS1001FM
ASN Flow Rate and Sonic Conductance AQ ASV AS1001F AS2001F AS3001F AS2051F AS4001F Model Metric size 3.2, 4, 6 4 6 6 8 6 8 10, 12 10 12 Tubing O.D.
13.7 134.3 138.5 93 10 12 55 376.4 149.5 78.4 M10 x 1.5 19 13 36.5 10.3 M8 x 1.25 10 112 54 12 16.6 141.2 147.5 90.5 10 12 55 395.6 158.5 78 M10 x 1.5 22 13 36.5 15.8 M8 x 1.25 10 76 13 19.6 199 137.5 18 80 214 113.7 21 50 20.8 M10 x 1.5 12 154 185.8 12 530.9 M12 x 1.75 30 Bore size (mm) 50 63 80 XC PA PB PC PD R RA RB RR S V VA VB VC VD VE VF W XA XB 50 45 10 55 45 68 45 48 11 8 30 32 63.5
Series MXP/MXPJ6 11226, 10, 12, 16 Air Slide Table How to Order Clean series 11 Vacuum suction type MXP 11 12 15 M9N MXP 22 12 15 M9N Copper, fluorine and silicone-free + Low particle generation Number of auto switches Nil S n 2 pcs. 1 pc. n pcs. 22 Vacuum suction type Bore size Stroke (mm) Auto switch 6 10 12 16 5, 10 10, 20 15, 25 20, 30 Nil Without auto switch Refer to the table below
(Values at the initial period) Dustproof VZS VFS VS4 VQ7 Solenoid Specifications EVS Base mounted Grommet (G), DIN terminal (D) 100, 110, 200, 220, 240 6, 12, 24, 48 10% of rated voltage 9.5 VA/50 Hz, 8 VA/60 Hz 7 VA/50 Hz, 5 VA/60 Hz Electrical entry VFN AC DC Rated voltage (V) Allowable voltage fluctuation Inrush Holding Apparent power (AC) Body ported Diode (12 VDC or less: Varistor) Varistor
In that case, loosen the screw with washer o and place a lead wire into the bracket , and then tighten it once again. b The maximum size for the round terminal o is 1.25 mm23.5 and for the Y terminal is 1.25 mm24. c Cable i outside diameter: 6 to 12 mm Note) For the one with outside diameter ranged between 9 to 12 remove the inside parts of the rubber seal u before using. 3.
15 60 108 15 80 600.05 +0.015 0 2 x 8H7( ) depth 12 (2 x 4 x M5 x 0.8 through) For limit switch mounting C B A0.5 55 55 1000.3 Switch mounting bracket Note 2) 12 70 12 Fulcrum 13 40 15 10 F 2 x 4 x M10 x 1.5 depth 12 107 Note 3) 70 2 x 2 x 8H7 +0.015 0 ( ) depth 12 60 1 52 (58.7) (70) 95 700.05 85 75 330 270 0.3 193 (173) 133 25 100 100 (10) Rc1/ 4 Unclamp side port 306 (30.2) (30.2) 360
(Upper/Metric, Lower/Inch) Series Filtration area [mm2] IN side > OUT side 2 3.2 4 6 8 10 12 IN side OUT side Applicable tubing O.D.
OUT2 White OUT2 12 to 24 VDC 12 to 24 VDC FUNC FUNC U Blue DC () Blue DC () -E PNP (1 output) + Analog voltage output -F PNP (1 output) + Analog current output Brown DC (+) Brown DC (+) Black OUT1 Black OUT1 + + White OUT2 White OUT2 12 to 24 VDC 12 to 24 VDC Load Load FUNC FUNC U Blue DC () Blue DC () The FUNC terminal is connected when using the copy function.
ZSE ISE ZSP Fig. (2) Equivalent circuit of an NPN switch with the output off PS PLC Low level 12 to 24 [VDC] Main circuit of switch ISA Max. 80 [mA] Max. 30 [V] Load PSE Current flows. Load is powered. IS ISG Fig. (3) Equivalent circuit of an NPN switch with the output on ZSM PNP 12 to 24 [VDC] Fig. (4) shows an example of a PNP switch.
Brown DC (+) ZF (OUT1) Black + Covering retainer Core wire crimping area Load ZP 12 to 24 VDC 80mA Core wire Lead wire Socket Blue DC () SP Hook Covering 3.
-wire (PNP) 12 V 2-wire Relay, PLC 3-wire (NPN) 3-wire (PNP) IC circuit Grommet 5 V, 12 V 24 V Diagnostic indication (2-color indication) 2-wire 12 V 3-wire (NPN) 3-wire (PNP) IC circuit With timer 5 V, 12 V Lead wire length symbols: 0.5 mNil (Example) E76A 3 mL (Example) E76AL 5 mZ (Example) M5NTZ Solid state switches marked with are produced upon receipt of order.
Auto switch model Electrical entry direction Lead wire length (mm) Load voltage Type Electrical entry Indicator light Wiring (Output) Special function Applicable load 5 (Z) AC DC 0.5 (Nil) 3 (L) Perpendicular In-line Z76 5 V IC circuit 3-wire Yes Reed switch Z73 12 V 100 V Grommet Relay, PLC 24 V 2-wire Z80 5 V, 12 V 100 V or less No IC circuit Y59A Y69A 3-wire (NPN) IC circuit 5 V, 12
. 12.1. . 12-1 . 12-1 EX245-EA2-1 . 11-1 EX245-SPN1A/SPN2A/SPN3A n 0 1 2 3 4 5 6 7 8 L 113.6 167.6 221.6 275.6 329.6 383.6 437.6 491.6 545.6 L = 54n + 113.6(8 ) mm 80 No.EX-OMW0014CN-A 13. 13.1.
min (250 L type) [ P_2] Set value (OUT2) [F 2]/[ oUt2] Page 37 5% of max. rated flow [ 0.20] 0.20 L/min (4 L type) [ 0.8] 0.8 L/min (16 L type) [ 2.0] 2.0 L/min (40 L type) [ 5] 5 L/min (100 L type) [ 12] 12 L/min (250 L type) [ H_2] Hysteresis (OUT2) [F 3]/[ RES] [ rES] Response time setting [ 1 .00] 1 second Page 41 [F10]/[ SUb] [ SUb] Selection of sub screen [ oUt] Display of set value
Controller 1)IZTC41 For IZTC41-L, refer to the IO-Link dedicated instruction manual. 1 2 3 4 5 6 14 7 8 13 12 10 9 11 Table4. Name of parts No.
MXQ6A M40.7 2.1 8 11 MXQ8A M40.7 2.1 8 11 MXQ12A M50.8 4.4 8 12 MXQ16A M61 7.4 12 17 MXQ20A M61 7.4 9 MXQ25A M81.25 18 12 MXQ6B M40.7 2.1 5 8 MXQ8B M50.8 4.4 4 9 MXQ12B M61 7.4 7 12 MXQ16B M61 7.4 10 15 MXQ20B M81.25 18 14 20 MXQ8C M40.7 2.1 6 9 MXQ12C M50.8 4.4 8 12 MXQ20(A)MXQ25(A) (L2)0.5mm ,, 6 L1 (Nm) (mm) MXQ6 M30.5 1.1 5.3 MXQ8 M30.5 1.1 8.3 MXQ12 M40.7 2.7 11.5 MXQ16 M50.8 5.4
YES NO NO 2 YES YES NO NO YES 10 2-2 (CEU2) (AC100V,15) (24V10,0.4A) (0.3MPa0.5MPa) 3) () (CE1-R**) (CE2**) 11 2-3 40 VFS240R VFS210 AR425 8/6 AN200-02 AS4000-02 50 VFS240R VFS210 AR425 10/7.5 AN200-02 AS4000-02 63 VFS340R VFS210 AR425 12/9 AN300-03 AS4000-03 80 VFS440R VFS310 AR425 12/9 AN300-03 AS420-03 100 VFS440R VFS310 AR425 12/9 AN400-04 AS420-04 12 * 3. 3-1 () 40 50 63 80
Tighten them with the hexagon socket head cap screw with washers 12 . 17 15 3 10 14 26 11 5 12 19 9 12 14 1 11 26 4 2 6 15 Cushion seal 4 Direction of the shaft(key) 38 - 7. Mount the pipe 21 to the sub-plate 18 19 and 30 and fix with hexagon socket head cap screws 22 31 to the body 1 . 8.
Additionally, note that the 12 VDC relay does not apply to the auto switch. -12- 11. Pay attention to leakage current. <2-wire type> Current (leakage current) flows to the load to operate the internal circuit even when in the OFF state.