SMC Corporation of America
Elite Part Number Search
Search Results "ISE70-N02-AB-LA"

Please contact us for the latest version.sales@ocaire.com, VALVE, MEDIA, VALVE, VEX PROPORTIONAL VALVE, LF, VEX BODY PT >3/4, 3.30693 lb, ModelBracketGrommetGrommet terminalConduit terminalDIN terminal ab?cdefghijVEX350110130912247140.5166179.5191

Please contact us for the latest version.sales@ocaire.com, POWER VALVE, VALVE, VEX PROPORTIONAL VALVE, JF, VEX BODY PT 1/2, 3.54363 lb, ModelBracketGrommetGrommet terminalConduit terminalDIN terminal ab?cdefghijVEX350110130912247140.5166179.5191

Please contact us for the latest version.sales@ocaire.com, POWER VAVLE, VALVE, VEX PROPORTIONAL VALVE, LF, VEX BODY PT >3/4, 3.35102 lb, ModelBracketGrommetGrommet terminalConduit terminalDIN terminal ab?cdefghijVEX350110130912247140.5166179.5191

Please contact us for the latest version.sales@ocaire.com, POWER VALVE, VALVE, VEX PROPORTIONAL VALVE, LF, VEX BODY PT >3/4, 4.66121 lb, ModelBracketGrommetGrommet terminalConduit terminalDIN terminal ab?cdefghijVEX350110130912247140.5166179.5191

Please contact us for the latest version.sales@ocaire.com, POWER VALVE, VALVE, VEX PROPORTIONAL VALVE, LF, VEX BODY PT >3/4, 3.60087 lb, ModelBracketGrommetGrommet terminalConduit terminalDIN terminal ab?cdefghijVEX350110130912247140.5166179.5191

Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance.  An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values.  The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, REPLCMNT BOWL, OTHERS, FHG HYDRAULIC FILTER, 21, FGH NO SIZE RATING

Pressure Range: ISE76G (0 to 5 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: B (Bracket B), Operation Manual/Calibration Certificate: K (Operation Manual + Calibration Certificate)

ZSE20C: ZSE20C, Rated Vaccum Range: F (-100 to 100 kPa), Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)

ZSE20C: ZSE20C, Rated Vaccum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)