Applicable Auto Switch/Refer to page 8-30-1 for further information on auto switches.
Rotate the assembly 30 (right or left) until the lock button is tossed up to mount the bowl assembly. Ensure the lock button is up.
Refer to page 30 for further information.
Applicable rotary actuator Applicable air gripper Size Page Size 30 50-100 10/15 20-100 10/15 20-40 32/40 1/3 7/20 10-200 10-25 10-25 10-40 10-30 16-25 32-125 10-25 32-63 20-50 CDRA1 CDRB CDRQ MRQ MDSUB MSQ MHZ2 MHZJ2 MHL2 MDHR MHS 12-25 MHK MHS MHC2 MHT2 MHW2 10-25 10/16 MHY MRHQ 2.11-8 D-A72/A73/A80 Grommet D-A72H/A73H D-A76H/A80H 2.11-9 Rail Connector 2.11-10 D-A73C/A80C D-A53/A54/A56
Left Symbol 1 N R Z Applicable models AR30 to 60 AR30 to 60 AR30 to 60 AR30 to 60 Note 1) K Body size 30 40 50 60 1 3 8 M 1 2 3 4 Display units for product name plate and pressure gauge: PSI, F.
S) (mm) Dimensions PB S Model LVD2-T LVD3-T LVD4-T LVD5-T PA 13 26 A B 26 29.5 Dimensions (mm) A B C D E F G H J K L M N P Q T U Model LVD2-T LVD3-T LVD4-T LVD5-T 30 30 61 56 14.5 104 35 13 4 20 44 7 30 6 31.5 17 M5 to 0.8 35 35 79.5 62 17.5 136 42.5 17.5 6 22 50 7 37 6 36 21 M5 to 0.8 35 35 82 62 20 137 45 17.5 6 22 50 7 39 6 36 21 M5 to 0.8 45 45 105.5 76 25 169.5 65 17.5 8 32 64 7 52 6
32 32 VCA21 VCA31 41 50 60 68 18 24 30 35 64 76 86 91 28 34 40 40 11.5 14 15 17.5 15 17 20 20 20.5 25 30 34 12.8 19 23 23 M4 M5 M5 M5 1/4 1/4, 3/8 3/8, 1/2 3/4 VCA41 17-2-13 8 Series VCA How to Order Manifold (VCA20) How to Order Manifold Assembly VV2C A 2 02 02 Enter the mounting valve and option part numbers under the manifold base part number.
Quantity 1 (VBA1A) 1 (VBA2A) 20 58 (CLOSE) to 63 (OPEN) q O-ring 1 1 Hexagon socket head taper screwed plug (for drain port) w OUT port Rc1/8 1 1 1 19 4 (VBA1A) 4 (VBA2A) Hexagon socket head cap screw e 4 4 Drain valve Anchor bolt/nut r 4 30 Body material: Brass For detailed dimensions, specifications and lead times, please contact SMC.
EX Maximum rated current Voltage with no load (V peak) 5.0 0 to 20 (V) 100 Exceeding 20 (V) up to 30 (V) Voltage figure at peak (2) Class 2 power supply unit in accordance with UL1310 or circuit (Class 2 circuit) in accordance with UL1585, that is powered by Class 2 transformer with the maximum of 30 Vrms (42.4 V at peak) 3.
D-A90, A90V Contact protection box CD-P11 CD-P12 OUT () Brown Reed switch OUT () Blue Unit: OZ, ( ): g Weight D-A90(V) 0.21( 6) 1.06(30) D-A93(V) 0.21( 6) 1.06(30) D-A96(V) 0.28( 8) 1.45(41) Model Lead wire length 30 in(0.5 m) Lead wire length 118 in(3 m) D-A93, A93V Brown (+) Contact protection box CD-P11 CD-P12 LED OUT (+) Brown Dimensions Reed switch Resistor Unit: in ( ): mm Zener diode
Adjustment bolt Stroke (mm) Stroke adjusters Auto switch 10 15 20 25 30 Series 5 Metal stopper Rubber stopper DShock absorber MXP 6 -X MXP 8 Lock plate MXP10 Individual -X Using lock plates to securely lock the adjustment bolt with minimal force.
in.Hg to 30 psig -30 in.Hg to 100 psig 0 to 200 psig 0 to 1000 psig 0 to 4000 psig -0.1 to 0.2 MPa -0.1 to 0.7 MPa 0 to 1.5 MPa 0 to 7 MPa 0 to 28 MPa Refer to the following porting configurations.
Rotary Actuator Vane Type CRB2 Series Size: 10, 15, 20, 30, 40 RoHS How to Order B S E 20 180 S Z CRB2 u Z L M9B CDRB2 B W 20 180 S With auto switch q r e !1 i o !
buffer, axial piping 6 Centralized adjuster 7 Centralized adjuster (Symmetric) 8 Buffer, Centralized adjuster 9 Buffer, Centralized adjuster (Symmetric) Nil 2 S 1 n n Port Switch mounting groove Port Switch mounting groove 8 10, 20, 30, 40, 50, 75 12 10, 20, 30, 40, 50, 75, 100 For details, refer to the next page. i Made to order 16 10, 20, 30, 40, 50, 75, 100, 125 Port Switch mounting groove
Cylinder stroke 30 40 30 mm (50, 63) Flange side Auto switch 40 mm (80) Nil Nil Without auto switch (Built-in magnet) Action D B T For applicable auto switches, refer to the table below. Auto switches are shipped together, (but not assembled).
20 20 30 75 100 22 22 30 40 62 7 7 12 16 19 " " " " " Inch size (2) Light and compact molded resin parts Cartridge type allows element replacement Note 1) Flow rate when initial pressure drop is 3 kPa or less.
Panel When mounting on a panel, refer to page 561 in Specific Product Precautions. 4.5 M5 x P0.5 8.5 M6 x P0.5 5.5 71 11 18 124 46 53 92 10 10 9.5 Bleed Bleed 63 Exhaust SUP(1) OUT(2) 30 OUT(2) SUP(1) 43 35 2 x Rc 1/8 Port size EXH 43 50 50 2 x Rc 1/4 Port size 2 x Rc 1/8 35 60 2 x Rc 1/8 Pressure gauge port Pressure gauge port 50 Mounting hole IR300-0 IR2120-02 36 2 Bracket (Option) 30
, 40, 50 M5 x 0.8 10, 20, 30, 40, 50, 75, 100 1/8 Double acting (Both sides) Non-lube 10-/12-/21-CXS6 6 Single rod 10-/12-/21-CXS10 10-/12-/21-CXS15 10-/12-/21-CXS20 10-/12-/21-CXS25 10-/12-/21-CXS32 10, 20, 30, 40, 50 10 15 20 25 32 M5 x 0.8 10, 20, 30, 40, 50, 75, 100 1/8 Specifications Suction Flow Rate of Vacuum Suction Type (Reference values) Bore size (mm) 10/15 20/25/32 6 Item 1.05
External pilot solenoid SGH 1 Y A G 1 T Z B1 10 0 30 3 SGHA 1 A G B1 10 0 3 30 Air operated q w e r t y u i o !0 !1 !
Exhaust/Flow Rate Characteristics 30 11.1. Ejector Exhaust Characteristics/Flow Rate Characteristics (Representative value) 30 11.2. Vacuum Release Flow Rate Characteristics (Representative value) 32 12. Limitations of Use 33 13. Troubleshooting 34 -1No. ZKJ-OM00201-D Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.